MAURY USCG vessel records
← All vessels

DOUBLESKIN 502

Built
2008
Last inspected
23 June 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 23 June 2026
…with no type recorded7
Operational controls None recorded without a removal date
Years with a record 19 calendar years (2008–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

939990
Flag
UNITED STATES
Maury page id
psix-939990

Documentation record

Registered dimensions (L × B × D)348.0 ft × 62.0 ft × 24.4 ft
Registered tonnagegross 4,238 / net 2,521
ITC dimensions (L × B × D)348.0 ft × 62.0 ft × 24.4 ft
ITC tonnagegross 4,238 / net 2,521
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2008
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBALTIMORE, MD
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 14 November 2025 · expires 31 October 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it4238 - Convention (Subpart B), Gross Ton
2521 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 34 inspections, each with its date, unit and type; 21 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; 2 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

DENVER Tank Ship · MISLE 1022490 · 17 September 2021 · activity 7314676MARILYN GEORGE Towing Vessel · MISLE 662923 · 8 July 2015 · activity 5177505MARILYN GEORGE Towing Vessel · MISLE 662923 · 20 June 2013 · activity 4626094

Inspection history · 34

23 June 2026 Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8372304
25 November 2025 Administrative Inspection · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8273925
12 November 2024 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8032284
22 December 2023 Damage Survey · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7841917
8 September 2023 Hull Examination · Internal Structural Exam · COI Inspection · Cargo Tank Internal
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7785077
24 May 2023 COI Inspection · MARPOL Annex VI Survey · MARPOL Annex I Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7691644
16 March 2023 Bulk Liquid Transfer Monitor
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7652293
1 September 2022 Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7549265
26 November 2021 Damage Survey · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7357802
17 September 2021 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7314676
17 September 2021 Deficiency Check · Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7314686
16 July 2021 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7257922
17 June 2021 Periodic Inspection · Internal Structural Exam · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7227805
22 September 2020 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7062933
20 September 2019 Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6816794
6 September 2018 MARPOL Annex I Examination · In-Service Inspection · Examination of Repairs · MARPOL Annex VI Survey · Hull Examination · MTSA/ISPS Verification · COI Inspection · Cargo Tank Internal · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6534271
18 October 2017 MTSA Verification · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6289258
3 August 2016 Internal Structural Exam · MTSA Verification · MARPOL Annex VI Survey · Underwater Inspection in lieu of Drydock · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5961224
30 September 2015 MARPOL Annex V Examination · MARPOL Annex II Examination · VRP Review · MARPOL Annex VI Survey · Periodic Inspection · MTSA/ISPS Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5761075
25 August 2015 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5226318
8 July 2015 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5177505
7 November 2014 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5020995
4 September 2014 MARPOL Annex VI Survey · SIP Inspection/Audit · MARPOL Annex I Examination · MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4974188
29 July 2013 MARPOL Annex I Examination · MTSA Verification · MARPOL Annex VI Survey · Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4671637
20 June 2013 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4626094
14 November 2012 MTSA Verification · MARPOL Annex I Examination · DAPI Audit · SIP Inspection/Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4484078
16 June 2012 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4347732
17 January 2012 Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4225712
16 January 2012 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4229703
20 September 2011 MTSA Verification · SIP Inspection/Audit · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4149789
3 December 2010 SIP Initial Entry
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3903487
10 November 2010 MTSA Verification · SIP Inspection/Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3888845
17 August 2009 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3568779
17 April 2008 Cargo Tank Internal · Internal Structural Exam · Initial Certification · Construction Oversight · MTSA Verification · Hull Examination
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3425092

Deficiency record · 21

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 June 2026 No resolution recorded
An examination of the vessel while afloat consists of a complete examination of the vessel's main strength members, including the major internal framing, the hull plating, voids, and ballast tanks, but not including cargo or fuel oil tanks. During an ISE MI observed 2 cracked welds in Void space number 4 on number 4 frame and in void space number 5 on number 2 frame. Vsl shall have welds repaired for next credit drydock.
Condition: Invalid
Action required: 705 - Other - as specified
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 November 2023 Resolved
The Rules concerning lights shall be complied with from sunset to sunrise, and also be exhibited from sunset to sunrise in restricted visibility. Flashing amber light was inop. Rectify prior to conducting ops that require the inop light within 14 days. 33CFR83.20(a))b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2023
Resolved 6 November 2023
Resolution: Received objective evidence of the amber light flashing. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 November 2023 Resolved
Portable extinguishers and their stations must be numbered in accordance with § 35.40–25. Each fire extinguisher shall be marked with a number and the location where stowed shall be marked with corresponding number in a last 1/2: figures. Portables not marked.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2023
Resolved 9 November 2023
Resolution: Recieved objective evidence; all sat.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 17 September 2021 Resolved
Vessel allided with pier and another vessel moored at the pier. Provide ABS findings, repair proposal, welder certifications and material specifications for repairs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2021
Resolution: class report received.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 June 2021 Resolved
Cracked stitch weld along the side shell identified in the lower level of the aft rake located next to the starboard ladderwell. To be repaired prior to next credit drydock.
Action required: 705 - Other - as specified
Resolved 26 October 2023
Resolution: Re-welded
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 June 2021 Resolved
High level audible alarms did not sound on deck. The high and overfill alarms did not sound in the accommodation house either. Make repairs and prove proper operation prior to loading cargo.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2021
Resolution: Received video of repaired alarms.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 June 2021 Resolved
#4S high level light did not activate. Make repairs and prove proper operation prior to loading #4S tank.
Action required: 705 - Other - as specified
Resolved 17 June 2021
Resolution: Received video of functioning light.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 17 June 2021 Resolved
Bleeder valve located on the starboard cargo pump was being held up by a bungee cord. Make repairs and prove proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 June 2021
Resolution: Received picture.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 22 September 2020 Resolved
Vapor leaks on tank tops of tanks #1S and #3P. Vapors must vent through cargo tank venting arrangements. Make repairs and prove proper operation. 46 CFR 32.55-25
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2020
Resolved 13 October 2020
Resolution: MI verified tanks had been resealed, no further vapor leaks.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 22 September 2020 Resolved
Vapor leaks on sight glass of tanks #1P and #2P. Vapors must vent through cargo tank venting arrangements. Make repairs and prove proper operation. 46 CFR 32.55-25
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2020
Resolved 13 October 2020
Resolution: MI verified sight glasses had been resealed, no further vapor leaks.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 22 September 2020 Resolved
Vapor leaks at #2S low suction valve, #5P low suction valve, #5S high suction valve, and #1P overfill stick. Vapors must vent through cargo tank venting arrangements. Make repairs and prove proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2020
Resolved 13 October 2020
Resolution: MI verified valves had been resealed, no further vapor leaks.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 22 September 2020 Resolved
Missing stud on port side vapor control line connection. Install stud and prove proper arrangement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2020
Resolved 13 October 2020
Resolution: VCS flange stud has been installed.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 22 September 2020 Resolved
Generator space emergency lighting is inoperable. Make repairs and prove proper operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2020
Resolved 13 October 2020
Resolution: Battery replaced and emergency lighting now operational.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 September 2019 Resolved
On deck overfill audible alarm did not activate when testing the high/overfill alarms for all tanks. Identify cause of failure and repair so that the overfill alarm activates independent of the high alarm. 705 - Prior to cargo operations.
Action required: 705 - Other - as specified
Resolved 24 September 2019
Resolution: Tested alarms.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 September 2019 Resolved
Paint locker has no means of securing hatch. Due to a portable CO2 extinguisher being installed, install means for securing the paint locker hatch to prevent CO2 leakage from the protected space.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 October 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 September 2019 Resolved
Replace wasted valve handle for the forward cleanout valve on the cargo vapor line.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 September 2019
Resolution: Replaced valve handles.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 September 2019 Resolved
Replace wasted valve handle for the port-bow hydraulic control box.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 September 2019
Resolution: Replaced valve handle.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 September 2019 Resolved
Identify and repair source of hydraulic fluid leak on center-bow hydraulic control box.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 September 2019
Resolution: Repaired hydraulic leak.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 13 September 2012 Resolved
Hydraulic hose fittings on crane boom are rusted.
Due 22 September 2012
Resolved 22 September 2012
Resolution: Applied Densyl tape to fittings.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 March 2012 Resolved
Headache/sinus meds expired
Due 3 May 2012
Resolved 3 May 2012
Resolution: New meds placed in first aid kit.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 17 January 2012 Resolved
SECURE PORT SIDE CARGO PUMP UNTIL REPAIRED AND INSPECTED BY ATTENDING MARINE INSPECTOR.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 January 2012
Resolution: Witnessed operational test of port cargo pump while bunkering, test was satisfactory.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.