Inspection record

Last inspected 15 June 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD3968
Flag
UNITED STATES
Maury page id
psix-94047

Documentation record

Registered dimensions (L × B × D)142.7 ft × 60.0 ft × 9.6 ft
Registered tonnagegross 656 / net 446
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderEQUITABLE EQUIPMENT CO · MADISONVILLE, LA, UNITED STATES · built 1967
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBATON ROUGE, LA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 13 May 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it656 - Regulatory (Subpart C or D), Gross Ton
446 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 46 inspections, each with its date, unit and type; 94 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 5 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 5

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

D. W. GRIFFITH Towing Vessel · MISLE 142198 · 9 October 2024 · activity 8026936DELGENE Towing Vessel · MISLE 94679 · 1 January 2021 · activity 7120151ING6516 Freight Barge · MISLE 456238 · 1 January 2021 · activity 7120151IN075038 Freight Barge · MISLE 879519 · 1 January 2021 · activity 7120151IN135468 Freight Barge · MISLE 1229330 · 1 January 2021 · activity 7120151

Inspection history · 46

15 June 2026 Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8405497
29 May 2026 COI Inspection · Administrative Inspection · Vessel Attendance
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8377454
7 July 2025 Examination of Repairs · Vessel Attendance · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8178292
9 October 2024 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8026936
3 September 2024 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7990372
12 August 2024 Re-Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7961964
16 May 2024 Administrative Inspection · Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7913536
15 February 2024 Re-Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7865888
13 November 2023 MTSA Verification · Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7822695
14 August 2023 Administrative Inspection · MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7767978
16 May 2023 MTSA Verification · Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7689707
17 February 2023 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7638389
10 November 2022 Deficiency Check · Examination of Repairs · COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7592528
15 August 2022 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7534173
10 May 2022 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7447669
24 February 2022 Deficiency Check · Re-Inspection · Administrative Inspection · Examination of Repairs · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7401438
12 November 2021 Deficiency Check · Administrative Inspection · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7349838
5 May 2021 In-Service Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7195085
2 May 2021 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7225816
6 April 2021 Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7168915
24 March 2021 Re-Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7156683
18 February 2021 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7142183
4 January 2021 Administrative Inspection · Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7115486
1 January 2021 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7119811
1 January 2021 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7120151
30 December 2020 Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7117715
25 December 2020 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7117711
11 September 2020 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7056198
5 August 2020 In-Service Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7020823
25 July 2020 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7023374
20 July 2020 In-Service Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7011653
9 July 2020 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7001860
14 May 2020 Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6953356
21 June 2019 Examination of Repairs · Internal Structural Exam · Drydock Exam · Administrative Inspection · COI Inspection · Construction Oversight · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6720875
13 September 2018 Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6539528
22 March 2018 Examination of Repairs · Deficiency Check · MTSA Verification · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6374273
10 January 2018 MTSA Verification · Examination of Repairs · Re-Inspection · Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6335727
21 September 2017 Re-Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6272728
29 June 2017 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6195919
21 March 2017 Administrative Inspection · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6108583
3 January 2017 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6065102
21 September 2016 Deficiency Check · Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6011502
18 June 2016 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5916553
22 April 2016 Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5860365
22 March 2016 Administrative Inspection · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5837992
2 February 2016 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5808913

Deficiency record · 94

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 12 August 2024 Resolved
A vessel equipped with fixed pitch propellers must have on the navigating bridge and at the engine room control station a propeller speed and direction indicator for each shaft. Starboard side port engine control LCD screen is inoperable. Replace screen unit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2024
Resolved 3 September 2024
Resolution: LCD screen was repaired
08 - Alarms › N/A - No Subsystem › General alarm
Issued 12 August 2024 Resolved
Where the general emergency alarm signal cannot be heard over the background noise, there must be a red-flashing light or rotating beacon, in addition to the general emergency alarm signal that has sufficient intensity above the background lighting that would alert personnel in the space and is activated whenever the general emergency alarm signal in the space are activated. General alarm light located in the engine room was found inoperable. Repair or replace light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2024
Resolved 3 September 2024
Resolution: Light was replaced
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 August 2024 Resolved
Each battery charger enclosure must meet 46 CFR 111.01-9 Each charger must be suitable for the size and type of battery installation that it serves. Battery charger for the starboard main diesel engine was found inoperable allowing the starboard engine to secure itself upon loss of power. Repair or replace battery charger.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2024
Resolved 20 August 2024
Resolution: Reported complete.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 12 August 2024 Resolved
An audible and a visible alarm must activate in the pilothouse upon failure of the electric power to the control system of any steering gear; failure of that power to the power unit of any steering gear; or occurrence of a low oil level in any oil reservoir of a hydraulic, power-operated steering-gear system. Vessels #2 steering gear alarms where found to going off intermittently for unknown reasons. Trouble shoot and repair alarm circuit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2024
Resolved 3 September 2024
Resolution: Steering gear alarm was properly repaired
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 August 2024 Resolved
Each navigation light system must meet the following: Dual light sources. Each self-propelled vessel must have duplicate light sources for the side, masthead, and stern lights. Port side light and anchor light secondary light sources are inoperative. Renew secondary lights for port and all-around white anchor lighting.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2024
Resolved 20 August 2024
Resolution: Reported complete.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 August 2024 Resolved
Each vessel must carry lifebuoys approved under 46 CFR 160.050. The grab line shall be 3/8-inch diameter polyethylene, polypropylene, or other suitable buoyant type synthetic material having a minimum breaking strength of 1,350 pounds. The life buoy grab line on the starboard side is deteriorated. Replace grab line.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2024
Resolved 20 August 2024
Resolution: Reported complete.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 12 August 2024 Resolved
A card of instructions giving a clear summary of the radiotelephone distress procedure must be securely securely mounted and displayed in full view of the principal operating position. Emergency broadcast placard missing. Replace emergency distress broadcast placard. 47 CFR 80.868
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2024
Resolved 20 August 2024
Resolution: Reported complete.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 12 August 2024 Resolved
All valves and closing appliances, or other mechanisms which may be required to be operated for damage control purposes in case of an emergency shall be conspicuously marked with letters at least 1 inch high. The placards for fire dampers on main deck were faded and not legible. Replace fire damper placards.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2024
Resolved 20 August 2024
Resolution: Reported complete.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 August 2024 Resolved
Each battery clearly marked with an expiration date and used in an item of survival equipment must be replaced during the annual inspection if the expiration date has passed. The self-igniting lights on the ring buoys were expired. Replace batteries.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2024
Resolved 20 August 2024
Resolution: Reported complete.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 November 2023 Resolved
Approved fire extinguishing systems must be installed in internal combustion engine machinery spaces. Timer delay bottle on system was approved/rated to actuate supply valve at 30 seconds (in accordance with onboard procedures). The timer delay actuated at 25 seconds. Replace timer bottle so that actuation occurs at rated time stamped on the bottle (with an allowance of +20%/-0% of stamped time). With a requirement of a 30 second delay, the bottle should actuate between 30 and 36 seconds.
Action required: 60 - Rectify deficiencies prior to movement
Due 13 November 2023
Resolved 16 November 2023
Resolution: CO2 Time Delay activated at 33 seconds, within allowable limits.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 13 November 2023 Resolved
All alarm panels must be continuously powered. Battery back-up for engineering alarms was not operating.
Action required: 60 - Rectify deficiencies prior to movement
Due 13 November 2023
Resolved 15 November 2023
Resolution: Panel and alarm repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 November 2023 Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as is reasonable and practicable. The wheel house utilizes an extension cord and power strip to power 5 different appliances creating a potential fire hazard. Provide permanently installed outlets to power appliances that are permanently utilized (i.e. microwave, refrigerator, fan, radio/battery chargers).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2023
Resolved 15 December 2023
Resolution: Permanent electrical outlets installed.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 November 2023 Resolved
Illuminated exit signs are required and must be installed in accordance with subchapter J (Electrical Engineering Regulations) of this chapter. The "EXIT" sign in the passenger lounge (aft) illumination is inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2023
Resolved 15 December 2023
Resolution: Replaced new-in-kind.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 13 November 2023 Resolved
Each lighting fixture must meet UL 1598A or IEC 60092-306 standards. Light in starboard engine room was missing cover. Repair cover.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2023
Resolved 15 November 2023
Resolution: Repaired
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 November 2023 Resolved
Emergency lighting must be provided to allow crew to find their way to survival craft and embarkation stations. Emergency lights on the aft vehicle deck were not operating. Repair emergency lights.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2023
Resolved 15 November 2023
Resolution: Repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 November 2022 Resolved
The minimum system monitoring requirement for reduction gears requires a high lube oil temperature alarm. During testing, high lube oil temp alarm for port reduction gear failed. Repair alarm.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 November 2022
Resolution: Alarm repaired and tested within parameters.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 November 2022 Resolved
The minimum system monitoring requirement for propulsion control air is to have an alarm for low control air pressure. Alarm for low control air pressure only activated at 50 PSI, when it should activate at 90-100 PSI. Repair control air alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2022
Resolved 29 November 2022
Resolution: Revised PSTPs, alarm no longer applicable
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 14 November 2022 Resolved
Each lighting fixture must meet UL 1598A or IEC 60092-306 standards. Light in starboard engine room was missing cover. Repair cover.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2022
Resolved 2 December 2022
Resolution: Cover repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 14 November 2022 Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed hazards, such as rotating machinery. Covers were missing over shaft couplers to main engines. Replace covers in way of main engine shaft couplings for both main engines.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2022
Resolved 2 December 2022
Resolution: Guards installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 November 2022 Resolved
Each life jacket aboard vessel must be approved under approval series 160.155, 160.176, or 160.177. Additionally, each life jacket container must be marked with the proper quantity of life jackets within. 2 adult size life jackets were found unserviceable. Unserviceable life jackets were in excess of required carriage amount. Replace unserviceable life jackets or change label on container to match actual number within (if unserviceable life jackets will not be replaced).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2022
Resolved 2 December 2022
Resolution: Lifejackets replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 May 2022 Resolved
The material, design, workmanship, and arrangement must be equivalent to ABS standards for engineering systems. The support bearing on the port shaft has a loose top cap. Repair bearing.
Action required: 10 - Deficiency Rectified
Resolved 10 May 2022
Resolution: Repaired prior to completion of inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 May 2022 Resolved
Each lifebuoy self igniting light must be of the approved type and operational. Repair life buoy light on starboard side.
Action required: 10 - Deficiency Rectified
Resolved 10 May 2022
Resolution: Repaired prior to completion of inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 May 2022 Resolved
Each vessel must carry a life jacket that meets required approvals for each person on board. Replace 03 unserviceable adult life jackets.
Action required: 10 - Deficiency Rectified
Resolved 10 May 2022
Resolution: Repaired prior to completion of inspection.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 10 May 2022 Resolved
All portable fire fighting equipment shall be maintained in accordance with NFPA 10. Exterior fire extinguishers were issing service tags. Ensure all extinguishers are properly serviced.
Action required: 10 - Deficiency Rectified
Resolved 10 May 2022
Resolution: Repaired prior to completion of inspection.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 24 February 2022 Resolved
A vessel required to have Type I or II subdivision must be watertight below the bulkhead deck. Additionally, bilges must be kept to a minimum content at all times. Starboard rudder tube/through hull fitting is leaking approximately 0.25 gallons per minute when vessel is underway. Also, pump excess water out of steering space.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2022
Resolution: Leak repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 February 2022 Resolved
The material, design, workmanship, and arrangement must be equivalent to ABS standards for engineering systems. The water pump on the starboard main engine leaks from the seal. Repair water pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2022
Resolved 10 March 2022
Resolution: Leak repaired.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 24 February 2022 Resolved
Emergency lighting must be provided to allow crew to find their way to survival craft and embarkation stations. Emergency lights on the aft vehicle deck were not operating. Repair emergency lights.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2022
Resolved 10 March 2022
Resolution: Lighting repaired.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 24 February 2022 Resolved
The operator of each self-propelled vessel 12 meters or more in length shall carry on board a copy of Inland Navigation Rules. Ensure a current copy of Inland Navigation Rules is placed in the wheelhouse.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2022
Resolved 10 March 2022
Resolution: Nav rules placed on bridge.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 November 2021 Resolved
Approved fire extinguishing systems must be installed in internal combustion engine machinery spaces. Timer delay bottle on system was approved/rated to actuate supply valve at 30 seconds (in accordance with onboard procedures), but timer delay actuated at 40 seconds. replace timer bottle so that actuation occurs at rated time stamped on the bottle (with an allowance of +20%/-0% of stamped time). With a requirement of a 30 second delay, the bottle should actuate between 30 and 30 seconds.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 23 December 2021
Resolution: Time delay functioned properly
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 November 2021 Resolved
Approved portable and semi-portable extinguishers must be installed in accordance with table 76.50-10(a). Service or replace two fire extinguishers in the engine room and the one extinguisher in the passenger space.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 23 December 2021
Resolution: Extinguishers replaced
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 15 November 2021 Resolved
Each machinery space must be ventilated to ensure that, when machinery is running at full power, an adequate supply of air is maintained for operation of machinery and comfort of crew. Motor is inoperable for main supply ventilation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2021
Resolved 23 December 2021
Resolution: Vent fan repaired
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 15 November 2021 Resolved
Gears, couplings, and all machinery capable of injuring personnel shall be provided with adequate covers or guards. Shaft of the potable water pump must be fully guarded from accidental contact with personnel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2021
Resolved 23 December 2021
Resolution: Guard repaired
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 November 2021 Resolved
Each switchboard must meet the requirements of IEEE code 45-2002. Switchboard rear access is not locked. Provide lock for access.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2021
Resolved 23 December 2021
Resolution: Access has been locked
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 November 2021 Resolved
The material, design, workmanship, and arrangement must be equivalent to ABS standards for engineering systems. The dump valve on the port main engine starter leaks excessive air when engine is started. Repair dump valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2021
Resolved 23 December 2021
Resolution: Dump valve repaired
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 15 November 2021 Resolved
Fire pumps shall be fitted with a pressure gauge on the discharge side of the pumps. The installed pressure gauge was not working. Repair/replace gauge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2021
Resolved 23 December 2021
Resolution: Gauge replaced
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 15 November 2021 Resolved
Emergency lighting must be provided to allow crew to find their way to survival craft and embarkation stations. Emergency lights on forward starboard vehicle deck and inside the CO2 room were not operating. Repair emergency lights.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2021
Resolved 23 December 2021
Resolution: Emergency lighting repaired
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 November 2021 Resolved
Electric installations on vessels must ensure maintenance of services necessary for safety under all conditions. Water was discovered filling the battery box aft of the wheelhouse. Remove water and ensure safe installation of electrical equipment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2021
Resolved 23 December 2021
Resolution: Water removed from battery box
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 May 2021 Resolved
The material, design, construction, workmanship, and arrangement of main propulsion machinery and of each auxiliary, directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS Steel Vessel Rules. While transiting ICW vessel experienced vibrations. Upon third party diver inspection, damage to both propellers was identified. Conduct appropriate permanent repairs and operational testing to the satisfaction of the attending Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 26 October 2021
Resolution: The shaft was replaced with a new shaft. Witnessed satisfactory installation of the new shaft.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Ship's occupational safety and health policies and programmes
Issued 24 March 2021 Resolved
46 CFR 16.401 The employer shall provide an Employee Assistance Program (EAP) for all crew members [name withheld] must include an education program. The EAP education program is not displayed and distributed in accordance with 46 CFR 16.401(a). Implement an EAP education program in accordance with 46 CFR 16.401(a).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2021
Resolved 13 April 2021
Resolution: EAP information was posted in crew area as well as on the bridge.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 24 March 2021 Resolved
46 CFR 78.37-5 The master or person in charge of a vessel that is not required by 46 U.S.C 11301 to have an official logbook, shall maintain, on board, an unofficial logbook or record in any form desired for the purposes of making entries therein as required by law or regulation in this subchapter. Watertight door operation, loudspeaker system, steering gear, whistle, and means of communication, emergency lighting and power systems are not being logged in accordance with 78.37-5. The Department of Transportation for the State of Louisiana must develop a corrective action plan for maintaining required log entries.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2021
Resolved 13 April 2021
Resolution: Port Engineer provided masters a comprehensive list of things to be recorded and a record to document the items.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 24 March 2021 Resolved
46 CFR 112.15-5(a) The emergency lighting power loads listed in paragraphs (b)-(l) shall be arranged so that they can be energized from the final source. All emergency lighting in the steering compartment, shaft alley, and all lights in the engine room except for one, did not illuminate when the power from the generator was secured. Repair all engine room emergency lighting to the satisfaction of the Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2021
Resolved 13 April 2021
Resolution: All E lights were tested satisfactorily
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 March 2021 Resolved
46 CFR 111.15-25(a) An overload protective device shall be placed in each battery conductor, except that engine cranking batteries need not be protected against overload. Both 12 volt battery banks located port and starboard aft corners of the engine room have several conductors attached with no overload protection. Provide fuses for all wires that are not for engine cranking to the satisfaction of the Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2021
Resolved 15 November 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 March 2021 Resolved
46 CFR 111.15-25(a)An overload protective device shall be placed in each battery conductor, except that engine cranking batteries need not be protected against overload. Both generator starting battery banks have auxiliary wires attached other than cranking leads that do not have overload protection. Provide fuses for all wires that are not for engine cranking to the satisfaction of the Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2021
Resolved 15 November 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 March 2021 Resolved
46 CFR 111.30-159b)(7)Adequate means for ground detection shall be provided on the ship service generator and distribution switchboard for ship’s main power system. The center bulb for 240 volt ground detection is burned out. Replace bulb in kind.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2021
Resolved 13 April 2021
Resolution: Ground detection system repaired
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 March 2021 Resolved
46 CFR 78.47-30(a)Each hand portable fire extinguisher shall be marked with a number and the location where stowed shall be marked with a corresponding number at least 1 /2 inch high. Four extinguishers outside of the superstructure and all of the engine room fire extinguishers were not numbered to their corresponding location. Mark portable extinguishers to their corresponding location to the satisfaction of the attending CG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2021
Resolved 13 April 2021
Resolution: All extinguishers were properly marked with the corresponding station number.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 24 March 2021 Resolved
46 CFR 112.15-5(a)46 CFR 112.15-1(h)Emergency lighting power loads shall be arranged so that they can be energized by the final source. The starboard aft and aft door “Exit” signs on the main deck superstructure leading to the open deck did not illuminate during the emergency power test. Repair or replace “Exit” signs to illuminate on emergency power to the satisfaction of the attending CG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2021
Resolved 13 April 2021
Resolution: All illuminated exit signs were tested satisfactorily.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 24 March 2021 Resolved
46 CFR 112.15-5(a) 46 CFR 112.15-1(h)Emergency lighting power loads shall be arranged so that they can be energized by the final source. The port forward and starboard aft exterior emergency lighting did not energize during the emergency power test. Repair or replace the emergency lighting to the satisfaction of the attending CG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2021
Resolved 13 April 2021
Resolution: Emergency lighting systems tested satisfactorily
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 24 March 2021 Resolved
46 CFR 112.05-10(d)Emergency lights shall be marked with a letter “E” of at least a ½ inch in height. The port forward exterior emergency light was not marked with an “E” and lighting in the E/R is marked with an "E" that is not emergency lighting or is not near a light fixture. Ensure all emergency lights are marked with a letter “E” and remove unnecessary "E" designations to the satisfaction of the attending CG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2021
Resolved 13 April 2021
Resolution: All E lights were properly marked.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 February 2021 Resolved
In addition to the emergency power sources required under part 112 of this chapter, each self-propelled vessel and each mobile offshore drilling unit must have at least two electric generating sources. Port generator is inoperable. Repair generator to the satisfaction of the Marine Inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 February 2021
Resolution: Electrician replaced voltage regulator on port generator.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 January 2021 Resolved
Each lifejacket must be marked with Type I retro-reflective material approved under approval series 164.018. The arrangement of the retro-reflective material must meet IMO Resolution A.658(16). 29 of the 156 lifejackets on board retro-reflective tape was found worn and lifejackets need to be replaced. Vessel will reduce the amount of passengers allowed on board to 125 until lifejackets are replaced to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 January 2021
Resolved 9 February 2021
Resolution: Lifejackets were replaced.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 4 January 2021 Resolved
All general alarm bells shall be identified by red lettering at least 1/2 inch high: “GENERAL ALARM—WHEN BELL RINGS GO TO YOUR STATION.”. The general alarm located forward of the bridge near the main deck is not marked with the required red lettering.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 January 2021
Resolved 14 January 2021
Resolution: General alarm bell was properly marked.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 January 2021 Resolved
Each hand portable fire extinguisher shall be marked with a number and the location where stowed shall be marked with a corresponding number at least 1/2 inch high. portable fire extinguishers in the E/R were found mislabeled. Vessel will correctly label the fire extinguishers IAW their fire control plan to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 January 2021
Resolved 14 January 2021
Resolution: All portable fire extinguishers and the respective locations were properly marked.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 January 2021 Resolved
The inspector shall examine all accessible parts of the vessel's hull, machinery, and equipment to be assured that it is in a satisfactory condition. Vessels visual and audible alarm for the steering gear space emergency escape hatch was found inoperable. Vessel will fix to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 January 2021
Resolved 9 February 2021
Resolution: Alarm operated properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 December 2020 Resolved
An inspection either general or partial depending upon the circumstances shall be made whenever any important repairs or alterations are undertaken. The second ship service generator starter has failed rendering the generator inoperable. Upon completion of repairs (installation of new starter) an inspection and testing of the generator shall be done to the satisfaction of a Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2021
Resolution: Witnessed satisfactory test of new generator starter.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 December 2020 Resolved
An inspection either general or partial depending upon the circumstances shall be made whenever any important repairs or alterations are undertaken. The second ship service generator starter has failed rendering the generator inoperable. Upon completion of repairs (installation of new starter) an inspection and testing of the generator shall be done to the satisfaction of a Coast Guard Marine Inspector.
Action required: 10 - Deficiency Rectified
Resolved 25 December 2020
Resolution: Port Engineer installed new pully on both SSGs and tested satisfactorily
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 September 2020 Resolved
Each pump shall be capable of delivering water simultaneously from the two highest outlets at a Pitot tube pressure of approximately 50 p. s. i. Both fire pumps are only producing 20 PSI. Repair pumps to produce 50 PSI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 September 2020
Resolution: Witnessed proper operation of both fire pumps.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 August 2020 Resolved
Distribution panels of the switchboard type shall be completely enclosed or otherwise protected against accidental contact and unauthorized operation. The 120V distribution panel in the aft of pilothouse has broken enclosure locking mechanism and the front of the panel is missing all but 2 securing screws. Repair distribution panel cover and locking door mechanism.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2020
Resolved 11 September 2020
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 5 August 2020 Resolved
Each item of lifesaving equipment carried on board the vessel in addition to those required by this part must be accepted by the cognizant OCMI for use on the vessel. All three blades of the rescue boat propeller are damaged with chunks of leading edge missing. Replace rescue boat propeller.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2020
Resolved 11 September 2020
08 - Alarms › N/A - No Subsystem › General alarm
Issued 5 August 2020 Resolved
Each general emergency alarm signal must be marked ‘‘GENERAL ALARM—WHEN EMERGENCY ALARM SIGNAL RINGS GO TO YOUR STATION’’ in red letters at least 1/2 inch high. The general alarm bells on the main deck exterior were not marked. Mark as appropriate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2020
Resolved 11 September 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 August 2020 Resolved
Each lifejacket must be marked in block capital letters with the name of the vessel. Two lifejackets were found to be marked with a different vessel name. Properly mark the lifejackets with the appropriate vessel name.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2020
Resolved 11 September 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 August 2020 Resolved
Each lifebuoy stowage position must be marked with either the words ‘‘LIFEBUOY’’ or ‘‘LIFE BUOY’’, or with the appropriate symbol from IMO Resolution A.760(18). The stowage location for lifebuoys stowed on the main deck were not legible. Mark lifebuoy stowage locations appropriately.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2020
Resolved 11 September 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 August 2020 Resolved
46 CFR 199.70(a) requires that each vessel carry lifebuoys approved under approval series 160.150. Amount of retro-reflective material on each lifebuoy was not of sufficient quantity or sufficient condition. Replace retro-reflective material to ensure a sufficient width (approx. 5cm) is applied around or on both sides of the body at four evenly spaced points.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2020
Resolved 11 September 2020
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 5 August 2020 Resolved
Liferaft Hydrostatic Release: Each liferaft or group of liferafts must be arranged for float-free launching. The arrangement must ensure that the liferaft or liferafts, when released and inflated, are not dragged under by the sinking vessel. A hydrostatic release unit (HRU) used in a float-free arrangement must be approved under approval series 160.162. The manufacturer's instruction on the installed disposable HRU for the vessel's survival craft requires an expiration date of two years after installation date. The expiration date required to be marked on the HRU was not marked and the vessel rep had no objective evidence of when it was installed. Install a new HRU and mark the expiration date in accordance with the manufacturer's instructions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2020
Resolved 11 September 2020
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 5 August 2020 Resolved
An emergency means of communication required by this subpart must— (1) Be comprised of either fixed or portable equipment; and (2) Provide common talking means of two-way voice communication and calling among the navigating bridge, emergency control stations, muster stations, embarkation stations, and other strategic positions listed in § 113.30–5. The crew does not carry a portable means of two way communication and the call button on the comms boxes located on main deck (exterior) do not operate to call the bridge. Prover proper operation of all call boxes onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2020
Resolved 11 September 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 July 2020 Resolved
The vessel is restricted to Bollinger shipyard and is not allowed to get underway until a complete root cause analysis is conducted o nthe entire steering system. This analysis is to include all mechanical, Hyd. And electrical components of the entire system. With all parameters tested, measured, observed, in the aforementioned sections of the steering system. A detailed report of the condition of the system and its serviceability for the future.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 July 2020
Resolution: Gap analysis recieved in form of steering technician report. Deficiency cleared. [name withheld].
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 July 2020 Resolved
When alteration or repair of machinery becomes necessary, the work shall be done under the cognizance of the Officer in Charge Marine Inspection. The port shaft cooper bearing failed rendering the port main engine inoperable. Repair to the satisfaction of attending USCG Marine Inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2020
Resolved 24 July 2020
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 7 May 2020 Resolved
Onboard training, musters, and drills must be in accordance with Subchapter W (Lifesaving Appliances and Arrangements) of this chapter. Drills were not witnessed during COI due to availability of personnel during COVID-19. Drills to be conducted at permanent operating location prior to carriage of Passengers to satisfaction of CG Marine Inspector. 46CFR78.17-50 701 c
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 May 2020 Resolved
All lifesaving appliances and arrangements on passenger vessels must be in accordance with Subchapter W. Observed 16 adult and 4 child lifejackets missing. Place on board in proper location prior to carriage of Passengers to satisfaction of CG Marine Inspector. 46CFR70.28-1 701 c
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2020
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 7 May 2020 Resolved
Observed several emergency lights inoperable. Repair as designed prior to carriage of Passengers to satisfaction of CG Marine Inspectors. 46CFR78.71-45 701 c
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 June 2019 Resolved
Several original documents not available for posting/review during COI due to COVID-19 travel ban. Documentation to be verified at permanent op location prior to carriage of passengers to satisfaction of CG. 701 c
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2020
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 22 March 2018 Resolved
Provide onboard valid Radio Safety Certificate IAW 47 CFR 80.1001(a)&(b).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2018
Resolution: Valid copy provided onboard.
Lifesaving › Inflatable Buoyant Apparatus › Weak Link
Issued 22 March 2018 Resolved
Install valid Hydrostatic release for port IBA IAW 46 CFR 199.130(c)(7).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2018
Resolution: Installed new hydro-release.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 22 March 2018 Resolved
Provide extension handle for hand brake on anchor winch. IAW 46 CFR 77.07-10.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2018
Resolution: Extension piece added to handle.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 22 March 2018 Resolved
Perform Annual maintenance for all on-board fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2018
Resolution: Annaul service performed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 March 2018 Resolved
Provide on-board approved first aid kit IAW 46 CFR 160.041 (b).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2018
Resolution: New approved first-aid kits onboard.
Electrical › Electric Supply System (service) › Cable
Issued 22 March 2018 Resolved
Repair or renew power wire for Rescue Boat winch motor IAW 46 CFR 111.60-5.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2018
Resolution: New wire conductor installed.
Pollution Prevention/Response › Prevention Equipment › Means of Removal from within Coaming
Issued 22 March 2018 Resolved
Remove all excess oil & water from under all machinery in engine room IAW 46 CFR 78.17-25.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2018
Resolution: Oily water removed from engineroom bilges.
Documentation › Markings/Placards › Garbage Placard
Issued 22 March 2018 Resolved
Update posted MARPOL placard with the latest edition.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2018
Resolution: Latest edition posted.
Construction/Loadline › Hull › Longitudinal Frame
Issued 22 March 2018 Resolved
Make permanent repairs to the fractured side shell longitudinal stbd side steering compartment. Location was pointed out to the master on-board at time of inspection IAW 46 CFR 72.01-15.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2018
Resolution: Satisfactory repairs made to the damaged frames.
Construction/Loadline › Hull › Weld
Issued 22 March 2018 Resolved
Clean and preserve weld seem fwd of stbd rudder assembly Location was pointed out to the master on-board at time of inspection, IAW 46 CFR 72.01-15
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2018
Resolution: Welds cleaned re-capped and preserved against further wastage.
Electrical › Electric Supply System (service) › Cable
Issued 22 March 2018 Resolved
Power wire for stbd rudder angle indicator has pulled out from the stuffing tube. Clean up wire and re-install into stuffing tube housing. IAW 46 CFR 111.60-5.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2018
Resolution: Wired cleaned up and installed properly.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 22 March 2018 Resolved
Straighten 4th up from the bottom ladder step on stbd E/R ladder. Location was pointed out to the master on-board at time of inspection. IAW 46 CFR 72.05-20(n).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2018
Resolution: Step removed and straightened.
Construction/Loadline › Hull › Weld
Issued 22 March 2018 Resolved
Clean and preserve spots in the fwd ballast tank. Location was pointed out to the master on-board at time of inspection. IAW 46 CFR 72.01-15.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2018
Resolution: All identified welds cleaned and preserved.
Lifesaving › Inflatable Buoyant Apparatus › Capacity
Issued 22 March 2018 Resolved
Provide onboard primary lifesaving for 147 total persons. Vessel has onboard one 100 person IBA, vessel is restricted to 96 passengers and 4 crew until additional IBA is installed. IAW 46 CFR 199.201(b)(1).
Action required: 705 - Other - as specified
Resolved 18 September 2018
Resolution: Vessel survival craft capacity reduced to reflect alternative standard outlined in 46 CFR 199.630(a) and (g).
Operations/Management › Vessel Activity › Underway
Issued 11 January 2018 Resolved
Vessel is restricted from carrying passengers for hire until the problem with the Port MDE engine throttle control is corrected and tested in the presence of the local attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2018
Construction/Loadline › Hull › Hull Plating
Issued 11 January 2018 Resolved
Make permanent repairs to the approx 2"-3" hole in the Port bow half round rub bar and test in the presence of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 February 2018
Resolution: Cropped and renwed approx 1' x 2' section of bow knuckle. Air tested satisfactory.
Electrical › Electric Supply System (service) › Battery Installation
Issued 11 January 2018 Resolved
Tighten negative battery terminals on both batteries for the Port MDE and repair wire insulation on attached wires IAW 46 CFR 111.
Action required: 705 - Other - as specified
Resolved 22 May 2018
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 11 January 2018 Resolved
Clean surrounding area of all Dirt, Grease, Oil and Water in the aft steering compartment.
Action required: 705 - Other - as specified
Resolved 22 May 2018
Engineering › Steering Gear System › Ram Seal
Issued 29 June 2017 Resolved
Repair or Replace port steering ram due to excessive leaking hydraulic fluid, and then prove the proper operation to the attending marine inspector, IAW 46 CFR 58.25-20.
Action required: 705 - Other - as specified
Due 14 July 2017
Resolved 14 July 2017
Resolution: Steering ram replaced with re-built one, all tested satisfactory.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 3 January 2017 Resolved
Vessel may only carry 65 adults and 12 children until 147 adult, 20 child life jackets are onboard to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 January 2017
Resolution: Verified 147 adult and 20 child lifejackets are onboard and in servicable condition.
Lifesaving › Launching Appliances › Falls
Issued 21 September 2016 Resolved
Renew rescue boat davit cable wire and provide a quick-disconnect for detaching the lifting bridal. Exsiting cable is crushed and fraying and the quick-disconnect is missing.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 September 2016
Resolved 30 September 2016
Resolution: Fall was renewed with new Amsteel Blue synthetic rope.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 21 September 2016 Resolved
Provide cover for 120 VAC outlet in crew space, IAW 46 CFR 111.81-1(c).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 September 2016
Resolved 30 September 2016
Resolution: New outlet cover installed.
Engineering › Lubricating Oil Service System › Piping
Issued 23 March 2016 Resolved
Provide safety guard for L/O tank sight glass.
Condition: Improper/Lack of Maintenance
Due 15 April 2016
Resolved 22 April 2016
Resolution: Guard installed
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 23 March 2016 Resolved
Prove proper operation of the STBD R/G lube oil pressure alarm.
Condition: Improper/Lack of Maintenance
Due 15 April 2016
Resolved 22 April 2016
Resolution: Witness alarm at 28 PSI