Records from 2008 to 2025. Most recent: inspection, 30 December 2025.
Inspection history · 47
30 December 2025
Periodic Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8288514
5 December 2025
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8278963
16 May 2025
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8137870
5 May 2025
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8129417
1 March 2025
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8095675
15 October 2024
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8019753
26 July 2024
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7967438
15 March 2024
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7884531
20 February 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7867640
26 January 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7856133
6 January 2024
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7846682
25 October 2023
MTSA Verification · MARPOL Annex II Examination · Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7791589
4 November 2022
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7589360
28 January 2022
Periodic Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7386819
12 November 2021
Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7351184
5 October 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7326999
23 February 2021
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7144893
11 January 2021
Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7122804
23 December 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7115704
6 March 2020
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6921785
10 February 2020
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6904973
7 January 2020
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6884245
5 November 2019
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6850426
15 October 2018
COI Inspection · Cargo Tank Internal · Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6561330
30 November 2017
Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6315370
22 November 2017
Plan Review (Other than "T") · Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6311483
20 May 2017
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6151452
27 February 2017
Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6099704
7 December 2016
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6056955
28 March 2016
Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5842626
5 January 2016
MARPOL Annex II Examination · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5790997
29 June 2015
In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5167888
20 June 2015
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5164123
13 January 2015
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5050571
30 December 2014
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4776551
21 January 2014
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4786853
23 September 2013
Drydock Exam · COI Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4728154
1 May 2012
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4299701
23 January 2012
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4229752
18 January 2012
Periodic Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4226600
26 April 2010
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3724580
14 January 2010
Annual Inspection
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3664421
31 July 2009
Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3551707
13 January 2009
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3403776
11 January 2009
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3392354
20 November 2008
Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3366538
20 August 2008
Initial Certification
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3303898
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 December 2025
No resolution recorded
Where required by the standard that is applicable to the listed or certified electrical equipment, seal fittings, termination fittings, or glands must be listed or certified by an independent laboratory for use in hazardous locations.
Cable penetration in FWD Port side of the N2 room is compiled of mixed components from different manufacturers. Repair at next Drydock
Condition: Improper Installation
Action required: 705 - Other - as specified
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 20 February 2024
Resolved
The master, owner, operator, agent, or person in charge of a vessel equipped with ballast tanks that operates in the waters of the United States must employ one of the authorized ballast water management methods listed in 33 CFR 151.2025(a). Vessel’s ballast water management system is inoperable. Vessel must comply with one of the methods listed in 33 CFR 151.2025(a) until system is repaired.
33 CFR 151.2025(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2024
Resolved 15 May 2024
Resolution: ACS (ABS) issued a finding report on 14 MAY 2024 (WO# 6407412) verifying the correction of the BWTS deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 January 2022
Resolved
Each cable installation must meet Sections 25, except 25.11, of IEEE 45-2002. Metal braid on several cargo deck cable installations is brittle and wasted. Replace corroded metal braid as needed by next dry dock.
46 CFR 111.60-5(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2023
Resolved 18 December 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 January 2022
Resolved
Each cable entrance into explosionproof or flameproof equipment must be made with approved seal fittings, termination fittings, or glands that meet the requirements of 111.105-9. Cable terminations into closed-gauging equipment were sealed with silicon. Reseal cable terminations using an approved method for hazardous locations to the satisfaction of the Coast Guard.
46 CFR 111.105-17(c)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2022
Resolved 4 February 2022
Resolution: Silicon was discovered to be covering approved glands. Vessel personnel removed silicon, reassembled glands and added denso tape as an additional protective barrier.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 13 January 2021
Resolved
Manned tank barges and tankships authorized to carry Grade A, B, C, or D liquids at any temperature, or Grade E liquids at elevated temperatures shall be provided with a combustible gas indicator suitable for determining the presence of explosive concetrations of the cargo carried. Vessel's fixed gas sampling system just received, and installed, a new sensor causing the system to give a constant alarm and not function as designed. Vessel's fixed gas sampling system must be tested to the satisfaction of the USCG and operate as designed. Vessel shall not carry flammable cargoes.
46 CFR 35.30-15(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 14 January 2021
Resolution: Witnessed calibration of gas sampling equipment and proper operation. Tested low flow fault indicator, all sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Dangerous Chemicals in Bulk (ICoF/IBC Code)
Issued 13 January 2021
Resolved
Non-self propelled ships must meet the requirements of this part (46 CFR 153) when the Officer In-Charge, Marine Inspection, issues a United States ship an IMO certificate endorsed to allow the carriage of hazardous material or NLS cargo in Table 1 of this part (46 CFR part 150, Table 1) in accordance with MSC. 460(101) updates to IBC all cargoes listed on the vessel's Cargo Authority Attachment and International Certificate of Fitness for Carraige of Dangerous Chemicals in Bulk may only be carried proved the vessel meets the requirements of MSC. 460(101), MEPC 318(74), and MEPC 315(74). Vessel's owner is required to contact Marine Safety Center to update Cargo Authority Attachment and request issuance of a new International Certificate of Fitness for the Carriage of Dangerous Chemicals in Bulk.
46 CFR 153.12(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 16 January 2021
Resolution: MSC completed updated CAA and P&A approval; new documents uploaded into MISLE. Issued amended COI and COF to vessel accordingly.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 February 2020
Resolved
Vessel must comply with hazardous location requirements. The Halogen light and housing located on top of the nitrogen generator house is not explosion proof or intrinsically safe.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2020
Resolved 6 March 2020
Resolution: Light was replaced with a Class I Division I LED light.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 February 2020
Resolved
The explosion proof light fixture located on top of the machinery room on the starboard side by the slop tank P/V was found with a cracked housing and is no longer explosion proof. Repair or Replace.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2020
Resolved 6 March 2020
Resolution: Lights were replaced and relocated.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 10 February 2020
Resolved
Anchor was found to have fractures on the inside of the links. Barges equipped with anchors are to comply with standards issued by a recognized class society. Vessel to provide class inspection report.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2020
Resolved 6 March 2020
Resolution: Class and servicing report was provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 February 2020
Resolved
The semiportable fire extinguisher was found to have the bottle neck highly corroded. Portable and semiportable extinguishers must be maintained in accordance with NFPA 10.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2020
Resolved 6 March 2020
Resolution: Fire extinguisher was taken out of service and replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 February 2020
Resolved
Hazardous location drawing had incorrect distances and must be updated to reflect the actual hazardous location.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2020
Resolved 6 March 2020
Resolution: Vessel Rep provided approved hazardous location drawing.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 5 November 2019
Resolved
ABS Surveyor discovered ODME system is not operable. Vessel must hold slops and discharge to shore until ABS clears the deficiency.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 January 2020
Resolved 7 January 2020
Electrical › Electrical Distribution System (service) › Panelboard
Issued 7 December 2016
Resolved
Seal holes at top of distribution panel (cargo control room, lower level).
Action required: 705 - Other - as specified
Due 7 January 2017
Resolved 6 January 2017
Electrical › Electrical Distribution System (service) › Cable
Issued 7 December 2016
Resolved
Repair fire block for cableway near cargo control room door.
Action required: 705 - Other - as specified
Due 7 January 2017
Resolved 6 January 2017
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 7 December 2016
Resolved
Show compliance with section 7 of CG-CVC Policy Letter 16-04.
Action required: 705 - Other - as specified
Due 1 March 2017
Resolved 6 March 2017
Resolution: Witnessed new arrangements o/b vessel.
Deck/Cargo › Vapor Control Systems › Inerting System
Issued 23 September 2013
Resolved
The fixed gas detection system was inop. System could not be calibrated.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 November 2013
Resolved 23 September 2013
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 23 September 2013
Resolved
Provide corrective action plan attesting to the proper training and record keeping of all required gas detection meters located on the barge. The crew did not have procedures for the calibration of the oxygen CO2 alarm for the NGG space.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 23 October 2013
Resolution: Vessel management provided procedure for proper training and record keeping of gas detection meters on the barge as well as procedures for calibration of the oxygen CO2 alarm for the NGG space and crew training.
Documentation › Certificates/Documents › International Air Pollution Prevention Certificate
Issued 20 January 2012
Resolved
Vessel has SOVC issued by ABS. Vessel needs valid IAPP cert. by 08Jan12 to operate on international routes. Restricted vessel to domestic voyages only.
Action required: 705 - Other - as specified
Resolved 1 May 2012
Resolution: Received copy of IAPP Certificate issued by ABS.
Construction/Loadline › Hull › Double Hull
Issued 18 January 2012
Resolved
Complete ISE prior to operating.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 January 2012
Resolution: Completed successful ISE checking all ballast tanks and voids.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 18 January 2012
Resolved
Vessel is required a hydrostatic twice in any five year period, not to exceed 3 years, due to the inability of a satisfactory internal examination.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 January 2012
Resolution: Witnessed hydrostatic test of both air receivers to 250 psi, all sat.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 January 2010
Resolved
Repair the port running light and the forward anchor light; insure the aft anchor light is working properly. A temporary port running light shall be rigged for night time operations until repairs have been affected.
Action required: 705 - Other - as specified
Due 19 February 2010
Resolved 16 February 2010
Electrical › Electrical Distribution System (service) › Switch
Issued 14 January 2010
Resolved
Repair the E-stop switch box for the #1 residue pump on deck; there are two broken screws on the cover plate.
Action required: 705 - Other - as specified
Due 1 February 2010
Resolved 12 February 2010
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 31 July 2009
Resolved
IAW 46 CFR 153.236(b) replace any brass fittings from the VCS piping to sat of attending MI.
Action required: 705 - Other - as specified
Due 30 September 2009
Resolved 30 September 2009
Resolution: Received statement and pictures from the Port [name withheld] attesting the replacement of all brass fittings in the barge.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 31 July 2009
Resolved
Update Cargo Authority Attachment (CAA) & amend COI to reflect latest approved CAA & to meet same reqmnts as the sister ship PETROCHEM SUPPLIER (ON 1211793). Contact cognizant OCMI to obtain amended COI, CAA & Cert. of Fitness and attachment NLT 30SEP09.
Action required: 705 - Other - as specified
Due 30 September 2009
Resolved 30 September 2009
Resolution: Sector New York was contacted on 29 Sep 09. Unit will issue new certificates.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pressure/Vacuum Relief Valve
Issued 31 July 2009
Resolved
P/V valve for cargo pump #2P is to be moved a min distance of 15 meters from any opening or air intake to accommodation & service spaces. Repair plan to be submitted w/ completion of approved repairs to be NLT 30SEP09. Certain cargoes (see scanned 835) are not to be carried in cargo tank #2P w/o prior approval from cognizant OCMI & use of add. monitoring during cargo ops.
Action required: 705 - Other - as specified
Due 30 September 2009
Resolved 30 September 2009
Resolution: Received statement and pictures from the Port [name withheld] attesting the relocation of P/V valve on deck.