MAURY USCG vessel records
← All vessels

PETROCHEM SUPPLIER

PETROCHEM SUPPLIER is a 2009 tank barge. The Coast Guard has recorded 32 inspections since 2009, most recently in July 2025, along with 19 deficiencies, 1 operational control and 2 casualty investigations between 2010 and 2013.

Records from 2009 to 2025. Most recent: inspection, 7 July 2025.

Built
2009
Last inspected
7 July 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

8745747
943851
Flag
UNITED STATES
Maury page id
psix-943851

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspections, by type

…with no type recorded2
Years with a record 16 calendar years (2009–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)491.8 ft × 72.0 ft × 41.0 ft
Registered tonnagegross 9,726 / net 9,726
ITC dimensions (L × B × D)491.8 ft × 72.0 ft × 41.0 ft
ITC tonnagegross 10,884 / net 6,139
BuilderBAY SHIPBUILDING CORP · STURGEON BAY, WI, UNITED STATES · built 2009
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portWILMINGTON, DE
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 17 October 2025 · expires 30 November 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it6139 - Convention (Subpart B), Net Ton
9726 - Regulatory (Subpart C or D), Net Ton
10884 - Convention (Subpart B), Gross Ton
9726 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CORPUS CHRISTI Towing Vessel · MISLE 921408 · 20 July 2014 · activity 4959410CORPUS CHRISTI Towing Vessel · MISLE 921408 · 2 April 2010 · activity 3715066

Inspection history · 32

7 July 2025 Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8178438
30 July 2024 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7970771
20 May 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7915679
29 April 2024 COI Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7899480
25 June 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7723499
27 July 2022 Administrative Inspection · Internal Structural Exam · Periodic Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7517641
2 April 2022 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7423428
28 February 2022 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7403077
18 October 2021 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7333679
18 October 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7335262
22 January 2021 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7129466
11 September 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7057451
17 February 2020 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6914537
13 June 2019 Drydock Exam · Cargo Tank Internal · COI Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6745660
23 April 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6673363
23 August 2018 Deficiency Check · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6521426
21 August 2017 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6242351
11 August 2017 Periodic Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6236612
16 May 2017 Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6148956
29 August 2016 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5986884
24 June 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5980684
8 September 2015 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5238684
28 August 2015 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5722504
20 July 2014 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4959410
3 June 2014 MARPOL Annex VI Survey · Welding Related Inspections Qualification Testing · Administrative Inspection · COI Inspection · MTSA/ISPS Verification · Internal Structural Exam · MARPOL Annex II Examination · Plan Review (Other than "T") · MARPOL Annex I Examination · MARPOL Annex IV Survey · Hull Examination · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4878050
10 July 2013 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4649688
7 October 2012 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4459286
9 August 2012 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4411573
23 July 2012 MTSA Verification · Internal Structural Exam · Periodic Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4383218
19 August 2010 MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3832169
2 April 2010 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3715066
21 January 2009 Construction Oversight · Internal Structural Exam · Initial Certification · Hull Examination · MTSA/ISPS Verification · MARPOL Annex VI Survey · Cargo Tank Internal
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3541660

Deficiency record · 19

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 18 October 2021 Resolved
The pressure used for the test required by 33 CFR156.170 must not be marked on the hose and must be recorded elsewhere at the facility. Cargo transfer hoses were found to be improperly marked with the hose test pressure.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 18 October 2021
Resolution: Vessel operator removed the test pressure from all onboard cargo transfer hoses.
09 - Working and Living Conditions › 092 - Working Conditions › Entry dangerous spaces
Issued 11 September 2020 Resolved
It was found that the emergency escape trunk/hatch within the Nitrogen Gas Generator (Inert Gas) space could not be opened. The opening/closing mechanism was seized and could not be actuated. 46 CFR 31.30-1
Action required: 10 - Deficiency Rectified
Due 11 September 2020
Resolved 11 September 2020
Resolution: Engineering crew assigned to the barge conducted maitenance; opening/closing mechanism was lubiricated and actuated.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 September 2020 Resolved
Two fire extinguishers within the Thermal Fluid Heater space were found to be held in place (attached to bulkhead) by improper mounting/retaining brackets. 46 CFR 34.50-20
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2020
Resolved 15 September 2020
Resolution: Proper brackets were installed on bulkhead and portable fire extinguishers securely held in place.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 11 September 2020 Resolved
The Class A fire boundary (bulkhead) separating the ship service generator space and the thermal fluid heater space was found to have open penetrations that may allow the passage of heat/smoke/flame. 46 CFR 32.57-10
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2020
Resolved 15 September 2020
Resolution: Penetrations in Class A Boundary were filled by installing steel bolts with retaining nuts into the holes.
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 30 July 2019 Resolved
Prior to leaving Veracruz, MX provide class report from ABS illustrating that all alarms associated with the commissioning of the Ecochlor system have been performed satisfactory.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 July 2019
Resolution: Received report form ABS stated alarms have been performed satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 30 July 2019 Resolved
Prior to departing Veracruz, MX Ecochlor's commissioning document must be completed, signed, and verified by all parties involved.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 July 2019
Resolution: Recieved signed commissioning document from vessel.
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 30 July 2019 Resolved
Prior to conducting ballast operations in the US, the ballast water treatment system must be verified fully operational, to include samples taken of ballast water.
Action required: 15 - Rectify deficiencies by next port
Resolved 2 August 2019
Resolution: Attended vessel and verified samples taken from ballast tanks are tested and water is able to be discharged.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 30 July 2019 Resolved
Prior to issuance of new SOVC ballast water management certificate, an updated and approved ballast water management plan must be onboard.
Action required: 705 - Other - as specified
Resolved 31 July 2019
Resolution: Recieved ABS approved updated ballast water management plan.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 23 August 2018 Resolved
Each vessel vapor connection flange must have a permanent stud projecting outward that has a .5inch diameter and is at 1 inch long. The VCS flange stud on the forward Starboard manifold was broken off. Provide proof of repair to the flange stud prior to conducting cargo operations requiring VCS use.
Action required: 705 - Other - as specified
Resolved 27 August 2018
Resolution: removed the reducer and installed a different reducer in its' Vessel crew removed the broken reducer and installed a different reducer in its place. Repairs made to original Flange stud on the reducer and kept as spare parts.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 August 2017 Resolved
Noted several wire nuts installed in various locations, replace the wire nuts with crimp on type connectors; noted three in the Skarpenord cabinet in the control room and three in the housing associated with the flame sensor for the thermal fluid heater.
Action required: 705 - Other - as specified
Due 10 September 2017
Resolved 21 August 2017
Resolution: Verified wire crimps have been installed in all locations where wire nuts wee listed.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 11 August 2017 Resolved
Lagging has been removed from the J/W piping on the inboard generator, replace lagging where missing.
Action required: 705 - Other - as specified
Due 10 September 2017
Resolved 21 August 2017
Resolution: Verified new lagging has been installed on the J/W piping of the inboard generator.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 11 August 2017 Resolved
Service records indicate that the portable fire extinguishers in the machinery space have not been serviced since June; conduct monthly maintenance and document accordingly.
Action required: 705 - Other - as specified
Due 10 September 2017
Resolved 21 August 2017
Resolution: Verified monthly maintainence of fire extinguishers has been conducted and logged correctly.
Documentation › Certificates/Documents › Certificate of Fitness (BCH Code)
Issued 28 August 2015 Resolved
Provide original certificate of fitness onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 September 2015
Resolved 18 September 2015
Resolution: Sector Mobile re-issued Certificate of fitness
Pollution Prevention/Response › Prevention Equipment › Means of Removal from within Coaming
Issued 23 July 2012 Resolved
Replace Spill pump hoses to Slop tank. Hoses are rotted and cracked.
Action required: 705 - Other - as specified
Due 23 August 2012
Resolved 9 August 2012
Resolution: Noted three new hoses installed.
Engineering › Diesel Engine (auxiliary) › Block
Issued 23 July 2012 Resolved
Replace hotel services generator radiator, radiator leaking coolant.
Action required: 705 - Other - as specified
Due 1 October 2012
Resolved 7 October 2012
Resolution: Ran generator, verified not leaks from radiator and all connections.
Electrical › Electric Generation Source (service) › Switch
Issued 23 July 2012 Resolved
Test reverse power relays, crew could not demonstrate proper operation of the reverse power relays.
Action required: 705 - Other - as specified
Due 23 August 2012
Resolved 9 August 2012
Resolution: Observed satisfactory operation of the both reverse power relays.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 23 July 2012 Resolved
Make repairs to IG s/w suction line in #5P ballast tank by next drydock. Line has been temporarily repaired.
Action required: 705 - Other - as specified
Due 31 July 2014
Resolved 24 October 2012
Resolution: Verified approx. 80ft of piping replaced satisfactorily.
Construction/Loadline › Markings › Load Line Mark
Issued 23 July 2012 Resolved
Repaint all load line and draft marks.
Action required: 705 - Other - as specified
Due 1 October 2012
Resolved 7 October 2012
Resolution: Verified draft marks and load line were painted.
Documentation › Logs/Records › Operational Procedures for Engines or Equipment
Issued 23 July 2012 Resolved
Provide TFH automatic control and safety test procedures for all required items IAW 61.30-20
Action required: 705 - Other - as specified
Due 1 November 2012
Resolved 9 August 2012
Resolution: Observed proper test procedures performed on the Thermal Fluid Heater as per requirement. (Def cleared by [name withheld] at MSU Savannah)

Casualty record · 2

2 April 2010Routine · role: Involved in a Marine Casualty · activity 3715066
6 February 2013Routine · role: Involved in a Marine Casualty · activity 4574280
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.