Records from 2012 to 2023. Most recent: inspection, 17 August 2023.
Inspection history · 81
17 August 2023
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7770725
11 May 2023
Re-Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7686302
10 May 2023
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7685313
15 April 2023
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7669316
14 April 2023
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7668782
14 April 2023
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7674884
12 April 2023
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7667357
28 March 2023
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7659052
13 March 2023
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7650333
11 March 2023
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7649999
2 February 2023
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7631240
27 January 2023
Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7628157
1 December 2022
Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7602897
1 December 2022
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7603024
3 November 2022
Re-Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7588768
11 October 2022
Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7574791
11 October 2022
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7576904
15 September 2022
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7559678
29 July 2022
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7519608
27 July 2022
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7517728
19 May 2022
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7458816
24 February 2022
MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7402081
6 January 2022
In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7377782
9 December 2021
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7374141
12 August 2021
In-Service Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7284805
21 July 2021
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7263407
10 June 2021
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7221464
11 February 2021
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7139391
23 October 2020
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7082785
13 August 2020
MTSA Verification · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7029830
4 June 2020
Re-Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6968218
15 April 2020
Damage Survey · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6939378
7 April 2020
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6936852
12 December 2019
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6872680
3 December 2019
In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6866338
19 August 2019
MTSA Verification · COI Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6788082
19 June 2019
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6719120
15 June 2019
Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6714625
15 June 2019
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6784178
25 May 2019
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6781552
23 May 2019
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6691631
1 March 2019
Administrative Inspection · Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6635073
7 February 2019
Re-Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6621863
24 November 2018
Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6587396
1 September 2018
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6529783
30 August 2018
MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6526390
11 April 2018
Administrative Inspection · Construction Oversight
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6389941
7 March 2018
Re-Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6367797
1 March 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6364066
5 January 2018
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6333175
30 September 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6563738
13 September 2017
Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6266648
7 September 2017
MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6261551
10 July 2017
Construction Oversight · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6204433
26 June 2017
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6187067
11 June 2017
Damage Survey · In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6173242
6 June 2017
Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6167532
3 June 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6180721
18 May 2017
MTSA Verification · Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6148719
10 May 2017
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6143312
2 May 2017
Deficiency Check · Damage Survey · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6137409
21 April 2017
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6129993
7 April 2017
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6119871
17 March 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6106749
2 March 2017
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6097958
17 January 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6071779
15 November 2016
Internal Structural Exam · Examination of Repairs · Drydock Exam · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6043000
28 October 2016
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6031291
14 September 2016
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6002396
9 September 2016
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5995752
4 August 2016
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5966754
4 August 2016
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5970253
1 August 2016
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5959312
13 July 2016
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5943851
24 June 2016
Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5917868
9 June 2016
Re-Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5902295
12 May 2016
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5875306
8 May 2016
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5872317
5 May 2016
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5870007
14 March 2016
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5832582
28 January 2016
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5805766
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 2 February 2023
Resolved
The emergency power source must meet table 112.05-5(a). The type of emergency power source must be an automatically started generator. Upon arrival, MI's observed the the emergency generator was not in the automatic start mode prohibiting the emergency generator from automatically starting. Ensure procedures are in place prior to getting underway to verify e-gen is in automatic mode and that the master is notified of this status. Provide USCG with proof of this procedure.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2023
Resolved 3 February 2023
Resolution: Recieved documentation attesting to procedures being in place.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 2 February 2023
Resolved
It shall be the duty of the owner, master, or persons in charge to see that the vessels firefighting equipment is at all times ready for use. MI's requested op test of the emergency fire pump activated from the pilothouse. The pump did not start due to open breakers within the electrical system rendering the pump inoperable. Chief engineer identified breakers and corrected the issue and conducted sat test of the fire pump. Ensure procedures are in place prior to getting underway to verify emergency fire pump is operational and that the master is notified of this status. Provide USCG with proof of
this procedure.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2023
Resolved 3 February 2023
Resolution: Recieved documentation attesting to procedures being in place.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 February 2023
Resolved
All portable fire extinguishers must be maintained in accordance with NFPA 10, Chapter 7. MI's observed 03 CO2 extinguishers with a previous service date of June 2021. Service or replace extinguishers maintained IAW NFPA 10. Provide evidence to USCG.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2023
Resolved 3 February 2023
Resolution: Recieved documentation attesting to equipment being maintained.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 February 2023
Resolved
The size of fire hoses and length of hose required, must be as specified in table 76.10-5(a). MI observed a 25' section of hose installed on the A end salon deck. Replace fire hose with 50' length of appropriate size. Provide evidence to USCG.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2023
Resolved 3 February 2023
Resolution: Recieved documentation attesting to equipment being maintained.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 February 2023
Resolved
Non-metallic flexible hose must be in accordance with SAE J-1942. MI observed deterioration of 2 jacket water hoses, one on each main engine on the top of the engine, MI made chief engineer aware of hoses. Replace hoses to the satisfaction of the USCG.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 February 2023
Resolved 14 February 2023
Resolution: @ jacket water hoses replace with new.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 2 February 2023
Resolved
Sufficient illumination must be provided by the emergency lighting source under emergency conditions to effect damage control procedures and to provide for safe egress from each space. Vessel is to install at next dry dock, additional emergency lighting in the B end emergency egress route in the oil tank compartment. Install at next drydock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 March 2023
Resolved 17 August 2023
Resolution: Vessel is in dry dock reconfiguring egress and emergency lighting. Sector houston notified this office that this deficiency will be rectified during dry dock.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 27 January 2023
Resolved
The installation of all lifesaving appliances and arrangements must be in accordance with the requirements of subchapter W of this chapter.
Vessel reported damages to the "A" end rescue boat. Replace with an approved rescue boat within 14 days to the satisfaction of a Coast Guard Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2023
Resolved 7 February 2023
Resolution: Replaced the existing rescue boat with one from the Ray Stoker Jr.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 2 December 2022
Resolved
Electrical installations on vessels must ensure maintenance of services necessary for safety under normal and emergency conditions.
Breaker #20 is tripping when shifting from shore power to ship power, and does not provide clear visually indication of a trip fault as it only jumps approximately 1/8 of an inch. This has resulted in the vessel running on battery power to the point where the vessel goes dead ship while conducting ferry operations across the Houston Ship Channel. Breaker #20 is to be replaced with a new breaker to the satisfaction of the [name withheld] and corrective actions to prevent recurrence shall be developed, carried out and provided to the satisfaction of the MI.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 December 2022
Resolved 10 January 2023
Resolution: Breaker was replaced. Low voltage alarms were also installed yo monitor AC voltage.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 October 2022
Resolved
The material, design, construction, workmanship, and arrangement of main propulsion machinery and of each auxiliary, directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS Steel Vessel Rules (incorporated by reference, see 46 CFR 58.03-1), except as otherwise provided by this subchapter. MI's observed missing and sheared engine mount bolts. Renew and replace missing/sheered engine mount bolts to the satisfaction of MI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2022
Resolution: New bolt was installed.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 12 August 2022
Resolved
46CFR76.15-10(e)
Where provisions are made for the simultaneous release of a given amount of fire suppressant by operation of a remote control, provisions shall also be made for manual control at the cylinders. MIs witnessed a temporary fix on a handle that was satisfactorily tested, replace the temporary handle with new handle to the satisfaction of MIs.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 August 2022
Resolution: Handle was replaced by certified tech.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 August 2022
Resolved
46CFR78.17-45
It shall be the duty of the master to see that the emergency lighting and power systems are operated and inspected at least once in each week that the vessel is navigated to be assured that the system is in proper operating condition.
MIs discovered inoperable emergency lighting in the shaft alley space. Repair lighting to provide ample lighting in the spaces for and aft of frames 46 A/B.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 August 2022
Resolution: Lighting was fixed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 August 2021
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician. If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate. Attending USCG Marine Inspectors found the vessel's Safety Radiotelephony Certificate had expired on 08/10/2021.
Action required: 705 - Other - as specified
Due 25 August 2021
Resolved 23 August 2021
Resolution: TXDOT provided copy of current issued certificate.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 August 2021
Resolved
Each vessel must carry a certificate with a valid endorsement while subject to the Bridge-to-Bridge Act. Attending USCG Marine Inspectors found the vessel's Bridge-to-Bridge certificate had expired on 08/10/2021.
Action required: 705 - Other - as specified
Due 25 August 2021
Resolved 23 August 2021
Resolution: TXDOT provided copy of current issued certificate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 August 2021
Resolved
All pressure vessels other than unfired steam boilers shall be protected by pressure-relieving devices that will prevent the pressure from rising more than 10 percent above the maximum allowable working pressure. Vessel crew was unable to demonstrate proper operation of the safety relief valve on the #1 air receiver when asked by the attending USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2021
Resolved 31 August 2021
Resolution: Witnessed SAT lifting of both 1 and 2 receiver safety relief valves at 250 psi.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 August 2021
Resolved
The applicable tests and inspections relating to annual inspection as set forth in subpart 71.25 shall be made at this time. For inspection procedures of marine engineering equipment and systems, see subchapter F (Marine Engineering) of this chapter. Vessel crew was unable to demonstrate proper operation of the installed bilge system when asked by the attending USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2021
Resolved 31 August 2021
Resolution: Witnessed SAT operation of the bilge system.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 August 2021
Resolved
All alarms must audibly annunciate until manually acknowledged. USCG Marine Inspectors found vessel with inoperable audible bilge alarms at the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2021
Resolved 31 August 2021
Resolution: Witnessed SAT test of audible/visual bilge alarms in both pilothouses.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 August 2020
Resolved
Repair keel cooler pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2020
Resolved 28 January 2021
Resolution: Pump replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 August 2020
Resolved
Repair "B" end E/R supply fan at next drydock.
Action required: 705 - Other - as specified
Due 27 August 2020
Resolved 28 January 2021
Resolution: Fan replaced
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 August 2020
Resolved
Complete Engine Order Telegraph (EOT) alarms test.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2020
Resolved 28 January 2021
Resolution: EOT repaired by third party.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 April 2020
Resolved
Electric installations on a vessel must ensure maintenance of services necessary for safety under normal and emergency conditions.
Vessel suffered loss of electrical power causing a loss of propulsion. The cause of the casualty should be determined and any repairs made to the satisfaction of the Coast Guard prior to departure.
46 CFR 77.05-1
46 CFR 111.01-1
17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 April 2020
Resolution: Repaired by ship's engineers. See statement in documents section.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 15 June 2019
Resolved
Vessel's rudder angle indicator is required to indicate the position of the rudder at the principal operating station. While conducting an operational test of the vessel's propulsion and steering systems following a grounding, Marine Inspectors discovered the indicator on the "A" end of the vessel did not match the actual position of the "A" end rudder. Prove to the satisfaction of the attending marine inspector the rudder angle indicator on the "A" end of the vessel is reading the true position of the "A" end rudder.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 June 2019
Resolution: Conducted sea trials and tested steering and rudder angle indicators all sat. MISLE 6719120
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 May 2019
Resolved
Replace after cooling return hose. Hose has 2 holes int it.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2019
Resolution: After cooling hose has been replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 February 2019
Resolved
Vessel did not complete Drydock and ISE by 22JAN2019 per COI exceeding five year period. Vessel will complete drydock and ISE no later than 28FEB2019.
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 February 2019
Resolved 23 May 2019
Resolution: Vessel was given credit drydock/ISE by Houston/Galveston.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 February 2019
Resolved
46CFR71.25-20(a)(1) - All portable fire extinguishers and semi-portable fire extinguishing systems must be maintained in accordance with NFPA 10, chapter 7.
02 portable fire extinguishers past hydro date. Corrected on the spot with new fire extinguishers.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 7 February 2019
Resolved 7 February 2019
Resolution: Put 02 new fire extinguishers onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 November 2018
Resolved
Steering failed to respond to commands from bridge. Master had to restart pumps from bridge before regaining control of steering in follow up mode.
Conduct diagnostic check of the electro-mechanical steering control systems and confirm all systems for steering are operating satisfactory.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2018
Resolved 25 November 2018
Resolution: Third party tech (Beier Radio) completed a diagnositc check of the steering system, completed adjustments and attested to the proper operation of the system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 September 2018
Resolved
#2 main generator on a diesel electric propulsion system inadvertently shut down. Vsl operator suspects a failed E-stop cause the shutdown. Third party to troubleshoot, class to attended and final sat repair report submitted prior to attending marine inspector carrying passengers.
Action required: 60 - Rectify deficiencies prior to movement
Due 2 September 2018
Resolved 4 September 2018
Resolution: Received tech report attesting to the proper operation.
Fire Fighting › Structural - A Class Divisions › Control Stations
Issued 7 March 2018
Resolved
The deck separating the pilot house from the emergency generator room does not meet A-60 structural fire protection as required by 46 CFR 72.05-10(g). Deck is missing insulation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 October 2018
Resolved 23 May 2019
Resolution: A-6- insulation was installed.
Engineering › Diesel Engine (propulsion-direct drive) › Emergency shutdown
Issued 13 September 2017
Resolved
Vessel's emergengy stop alarm activated causing the vessel to have reduction in propulsion.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 September 2017
Resolved 15 September 2017
Resolution: Received tech report and cleared vessel for operations.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 September 2017
Resolved
Three of four navigation light screens were not painted Matte Black. Repaint screens in matte black.
Action required: 705 - Other - as specified
Due 7 September 2017
Resolved 14 September 2017
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 7 September 2017
Resolved
Three Life ring had missing marking. Remark.
Action required: 705 - Other - as specified
Due 7 September 2017
Resolved 14 September 2017
Resolution: MI attended vsl and verified all life rings properly marked.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 12 June 2017
Resolved
Vessel reported that the generator "flickered"and half of the power to the vessels bus was dropped.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 12 June 2017
Resolved 12 June 2017
Resolution: MI's attended vessel and verified power loss never occurred only loss of radar due to UPS failure and engine room e-light failed due to faulty ballast. Both faulty items have been replaced. All Sat.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 6 June 2017
Resolved
Vessels rudder indicator and pump settings no longer function properly. Repair to satisfaction of Class and attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 June 2017
Resolution: Repairs made to satisfaction of attending mairne inspectors.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 18 May 2017
Resolved
Heat Detector in Battery Room "A" found taped up and assumed inoperable. Vessel must raplace/install properly and confirm operations to the attending marine inspector.
Action required: 705 - Other - as specified
Due 25 May 2017
Resolved 26 May 2017
Resolution: Received tech report attesting to the proper operation of the heat detectors.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 18 May 2017
Resolved
03 Lifejackets found not serviceable. Replace with new lifejackets on the "B" end.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 May 2017
Resolved 18 May 2017
Resolution: Corrected on the spot.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 21 April 2017
Resolved
Vessel experienced unusual shuddering...further damage investigation revealed damage to "A" end prop and rudder. Repair prop and rudder to the satisfaction of the class society and the attending Coast Guard marine inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2017
Resolution: Cleared 835 based on MI witnessing proper repairs to A end propeller and rudder shoes and receipt of ABS survey report.
Engineering › Fuel Oil Service System › Filter
Issued 2 March 2017
Resolved
Harbor/#2MDE F/O #1 filter is leaking F/O.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 March 2017
Resolved 3 March 2017
Resolution: Filter has been repaired.
Engineering › Fuel Oil Service System › Hose
Issued 2 March 2017
Resolved
Replace cracked and chaffed F/O supply hose and return hose for the harbor generator and return F/O hose on #1 MDE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 March 2017
Resolved 3 March 2017
Resolution: Hose has been replaced
Engineering › Lubricating Oil Service System › Piping
Issued 2 March 2017
Resolved
Add support bracket for L/O piping on outboard side of #1 MDE.
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 26 June 2017
Resolution: Add support bracket for L/O piping on outboard side of #1 MDE.
Engineering › Lubricating Oil Service System › Manifold
Issued 2 March 2017
Resolved
Repair L/O leak on #1 L/O heater
Action required: 705 - Other - as specified
Due 1 April 2017
Resolved 18 May 2017
Resolution: Verified by the attending Marine Inspector. All SAT.
Electrical › Electrical Distribution System (emergency) › Cable
Issued 2 March 2017
Resolved
In B end comp. #8 support call point wiring to overhead and remove sharp corners on overhead metal heading to the emergency exit.
Action required: 705 - Other - as specified
Due 1 April 2017
Resolved 18 May 2017
Resolution: Verified by the attending Marine Inspector. All SAT.
Engineering › Bilge Water Management System › Not Installed
Issued 2 March 2017
Resolved
Attach bilge alarm junction box to bulkhead in the A end Comp.#1
Action required: 705 - Other - as specified
Due 1 April 2017
Resolved 18 May 2017
Resolution: Verified by the attending Marine Inspector. All SAT.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 2 March 2017
Resolved
Adjust A end Comp. #1 emergency exit hatch
Action required: 705 - Other - as specified
Due 1 April 2017
Resolved 18 May 2017
Resolution: Verified by the attending Marine Inspector. All SAT.
Engineering › Freshwater System (intermediary cooling) › Piping
Issued 27 February 2017
Resolved
Vessel installed upgraded VFD cooling system (8 larger Alfa-Laval plate coolers) to help combat overhating issues within VFD system. Preliminary plans have been submitted to MSC but were returned for revision (MSC Letter E1-1700535). Obtain approved plans, and upon receipt of approved plans, make vsl available for inspection to satisfaction of attending Marine Inspector.
Action required: 705 - Other - as specified
Due 27 August 2017
Resolved 17 March 2017
Resolution: Received copy of MSC Approval Letter E1-1700762, which provided MSC plan approval for modifications to the VFD cooling system.
Accommodation/Occupational Safety › Washroom/Toilet › Location
Issued 27 February 2017
Resolved
Vessel installed new ADA restroom on deck and removed 2 emergency escape hatches during shipyard period. A preliminary updated general arrangement drawing has been submitted to MSC for review, but has not been approved at this time. Obtain approved general arrangement drawing, and upon receipt of approved plan, make vessel available for inspection to the satisfaction of attending Marine Inspector.
Action required: 705 - Other - as specified
Due 27 August 2017
Resolved 7 April 2017
Resolution: Received and reviewed MSC Approval Letter H2-170078, which approved updated general arrangement plans without any comments / requirements for local OCMI verification.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 27 February 2017
Resolved
A end pilothouse fire door leading to bridge walking deck has 2 cracks in glass window. Replace glass window to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 2 March 2017
Resolution: Windows were replaced. All SAT.
Engineering › Fuel Oil Service System › Filter
Issued 4 August 2016
Resolved
Wrote 835 to failed engine first.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2016
Resolution: MI witnessed satisfactory engine test and trial run.
Engineering › Diesel Engine (propulsion-electric) › Governor
Issued 13 July 2016
Resolved
Electronic control unit MA1 not communicating with engine.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2016
Resolution: Vessel conducted necessary repairs and sea trial. 835 cleared and OPCON removed.
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 24 June 2016
Resolved
Post allision accident caused vibrations during full speed trials.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2017
Resolution: Def should have been cleared earlier.
Electrical › Electrical Distribution System (service) › Switch
Issued 8 May 2016
Resolved
Transfer switch does not shift control from "A" end navigation bridge to "B" end. Prove proper operation of transfer switch to the satisfaction of the attending marine inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2016
Resolution: Crew proved satisfactory test of bridge transfer switch between A/B bridges to the satisfaction of the attending Marine Inspector.
Engineering › Steering Gear System › Rudder
Issued 28 January 2016
Resolved
VSL's steering circuit control card for the # 1 steering pump failed causing the rudder to
lock hard to starboard.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 January 2016
Resolved 29 January 2016
Resolution: MIs verified replacement of damaged circuit card and witnessed satisfactory operational test of the #1 steering system.