MAURY USCG vessel records
← All vessels

PM IMPERIAL

PM IMPERIAL is a 2007 tank ship. The Coast Guard has recorded 9 inspections since 2016, most recently in April 2025, along with 9 deficiencies — 1 with no resolution recorded — and 2 operational controls.

Records from 2016 to 2025. Most recent: operational control imposed, 5 April 2025.

Built
2007
Last inspected
5 April 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 April 2025
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9324306
9V2881
949655
Flag
SINGAPORE
Maury page id
psix-949655

Documentation record

Tonnage as PSIX records it43797 - Convention (Subpart B), Gross Ton
21967 - Convention (Subpart B), Net Ton
89786 - Displacement, Ton
74991 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

JUNO Towing Vessel · MISLE 151506 · 4 April 2019 · activity 6656201TED C. LITTON Towing Vessel · MISLE 1536720 · 4 April 2019 · activity 6656201

Inspection history · 9

5 April 2025 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8105668
24 March 2025 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8098647
12 March 2025 Deficiency Check · PSC B · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8092048
12 March 2025 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8092240
4 April 2019 Deficiency Check · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6655613
4 April 2019 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6656201
31 March 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6652943
29 December 2018 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6603107
6 July 2016 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5929220

Deficiency record · 9

07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 12 March 2025 Resolved
After any survey of the ship under regulations 7, 8, 9 or 10 has been completed, no change should be made to the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the administration. PSCO observed the gas temperature sensor on the inert gas line in the IG space requires removal from a modified ball valve to test, creating an unsafe atmosphere. 74SOLAS(20)I/11(b)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2025
Resolution: Spare sensor pocket put in place and existing sensore installed to the satisfaction of class/CG.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 March 2025 Resolved
Vent outlets for cargo loading, discharging and ballasting required by regulation 11.6.1.2 shall permit the free flow of vapor mixtures. PSCO observed all flame screens on P/V valves 1 through 6 on port and starboard tanks, as well as P/V breaker painted over restricting flow. 74SOLAS(04)II-2/4.5.3.4.1.1.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2025
Resolution: Crew cleared the P/V vent screens of any paint over-spray, debris etc.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 March 2025 Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect including those on board tankers, unless the equipment is appropriately certified for safe usage in the dusts, vapors or gases likely to be encountered. Bonding wires were found to be deteriorated or missing from piping in cargo pump room, on inter gas piping and cargo piping on deck. 74SOLAS(04)II-1/45.10.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2025
Resolution: Bonding wires that are damaged and/or missing renewed by crew.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 12 March 2025 No resolution recorded
The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the company. The technical and operational nature of the deficiencies noted provide objective evidence of a lack of effectiveness of the implementation of the ISM code. An internal audit is required within 03 months. 74SOLAS(20)IX/3.1 ISM PART A/10.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 4 April 2019 Resolved
A ship which is designed, constructed and maintained in compliance with the appropriate requirements of an organization including a classification society, which is recognized by the Administration or with applicable national standards of the Administration in accordance with the provisions of regulation 2-1, may be considered to provide an acceptable level of strength. The above provisions shall apply to all structures, equipment, and fittings covered by this annex for which standards for strength and construction are not expressly provided. On 04 APR 2019 at approximately 0558 while mooring at Buckeye Dock 3, the vessel allided with the dolphin pier tie off, forward starboard side way of number one ballast tank. Puncture approximately 1 foot by 3 inch approximate 8 feet above the water line. Vessel restricted in movement to inner harbor until classification survey is complete. ICLL (88) Annex B/Reg 1.2
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 April 2019
Resolution: Received class report attesting to the permenant repair of the puncture on the stbd side shell plating.
Lifesaving › Lifeboat › Fire Protection (water spray system)
Issued 6 July 2016 Resolved
0610- Lifeboats- A lifeboat which has a water spray fire-protection system shall comply with the following: the system shall be arranged for flushing with fresh water and allowing complete drainage. Crew was unable to provide means to flush with fresh water. SOLAS 74/78 III/34, LSA Code 4.9.2.3
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 12 July 2016
Resolution: Received class report from DNV stating deficiency has been cleared.
Construction/Loadline › Markings › Load Line Mark
Issued 6 July 2016 Resolved
1220- Freeboard Marks- The ring lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. PSCO observed freeboard lines on the port side were not appropriatly painted. ICLL 66 as modified Annex I/8 Rectify prior to next U.S. Port after sailing foreign.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 31 March 2019
Resolution: Vessel provided documentation that the deficiency had been cleared by Sector New Orleans via their CG-5437B from 29DEC2018. This document is attached to this activity for reference.
Operations/Management › Drills/Instruction › Not Conducted
Issued 6 July 2016 Resolved
2099- Other SOlas Operational Def.- Crew members with enclosed space entry or rescue responsibilities shall participate in an enclosed space entry and rescue drill to be held on board the ship at least every two months. The crew has not completed an enclosed space rescue drill withinn two months (April 25, 2016) SOLAS 74/78 III/19.3.3
Condition: Improper/Lack of Maintenance
Due 6 July 2016
Resolved 6 July 2016
Resolution: PSCO witnessed satisfactory Enclosed Space Entry and Rescue Drill during examination.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 6 July 2016 Resolved
1899- Other (tankers)- Each cargo tank of a tank ship must be equipped with an intrinsically safe high level alarm and overfill alarm. PSCO observed audible alarm for overfill not sounding on deck. Crew cleaned air line and tested alarms satisfactorily. 46 CFR 39.2007
Due 6 July 2016
Resolved 6 July 2016
Resolution: Crew cleaned air line and tested alarms to PSCO satisfaction.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.