BUFFALO 409 is a 2008 tank barge. The Coast Guard has recorded 27 inspections since 2008, most recently in September 2025, along with 5 deficiencies and 1 casualty investigation in 2008.
Records from 2008 to 2025. Most recent: inspection, 9 September 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS INC · ASHLAND CITY, TN, UNITED STATES · built 2008
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portHOUSTON, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 17 February 2026 · expires 28 February 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton 1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 5 December 2019Resolved
Thermal fluid heater not installed as per approved plans from MSC, serial number E1-1902172. Company representative stated updated plans have been sent to MSC for approval. Proof of submittal must be provided to the Coast Guard of the thermal fluid heater must be installed in accordance with approved plans.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 December 2019
Resolution: Received photos of the BUFFALO 409, thermal fluid heater fuel bypass installed IAW 46 CFR 63.15-5 and approved plans from MSC.
EPA's VGP eNOI system does not show 2017 and 2018 annual reports. Provide documentation that the annual report for discharges have been completed and filed with the EPA.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2019
Resolved 5 June 2019
Resolution: Received copies of the annual report and verified it was submitted electronically to the EPA
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 24 May 2019Resolved
The thermal fluid heater test procedures have not been approved by the Marine Safety Center. Submit procedures meeting 46 CFR 63.15 63.25-5, and 61.30 in accordance with 63.10-1. Provide an approved copy to attending inspector within 90 days.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 December 2019
Resolved 6 August 2020
Resolution: Attached test procedures in documents (activity number 7012274) and documents submitted from MSC for test procedure approval and plan approval.
16 December 2008Routine · role: Involved in a Marine Casualty · activity 3385008
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.