Records from 1997 to 2026. Most recent: inspection, 6 August 2026.
Documentation record
Registered dimensions (L × B × D)61.5 ft × 25.0 ft × 6.2 ft
Registered tonnagegross 122 / net 83
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJ F BRENNAN CO INC · LA CROSSE, WI, UNITED STATES · built 1967
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLA CROSSE, WI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 July 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it122 - Regulatory (Subpart C or D), Gross Ton
83 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 19
6 August 2026
Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8461547
10 June 2025
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8149892
9 April 2025
Drydock Exam · Internal Structural Exam · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8110277
14 May 2024
Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7912244
12 July 2023
Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7739262
6 September 2022
Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7552728
28 December 2021
Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7373128
29 August 2021
Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7299647
18 May 2020
Initial Certification
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6969040
15 March 2019
Administrative Inspection
Administrative · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6663815
7 September 2017
Uninspected Other
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6261807
3 October 2011
Industry Initiated Exam · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4174584
4 November 2010
Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 3884848
17 September 2010
Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 3853464
8 January 2007
Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 2852103
14 September 1998
Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 420413
11 December 1997
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 644449
20 October 1997
Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 409112
2 October 1997
Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 408524
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 10 June 2025
Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. Remote means to activate valve failed.
*****Corrected on same date******
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 June 2025
Resolution: Cable repaired and performed satisfactorily.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 June 2025
Resolved
A towing vessel must carry a combination of day and night visual distress signals. All approved distress signals on board were expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2025
Resolved 18 June 2025
Resolution: New approved flares placed on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 June 2025
Resolved
Each towing vessel must carry at least one approved appropriately-sized lifejacket for each person on board. COI authorized 15 persons on board, only 14 lifejackts (approved PFDs) on board.
Code 705: Vessel restricted in authorized persons allowed to be carried on board from 15 to 14.
Action required: 705 - Other - as specified
Resolved 18 June 2025
Resolution: One additional appropriately rated PFD placed on board.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 June 2025
Resolved
All portable fire extinguishers must be inspected or tested at least once every 12 months Annual servicing of the extinguisher located near the flammable/combustible products storage cabinet was overdue.
********Corrected*********
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2025
Resolution: Fire extinguisher replaced with one which had been serviced.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 10 June 2025
Resolved
All lifesaving equipment must be tested and maintained in accordance with the minimum requirements of § 199.190 of this chapter which states, "Each battery clearly marked with an expiration date and used in an item of survival equipment must be replaced during the annual inspection if the expiration date has passed." The waterlight's battery was expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2025
Resolved 18 June 2025
Resolution: New waterlights for ring buoys installed on vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 June 2025
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Cover plate was missing for outlet under helm console and attached to port bulkhead.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2025
Resolved 18 June 2025
Resolution: Outlet cover installed on outlet.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 14 May 2024
Resolved
Electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on-board under normal and emergency conditions. Water is coming in from the top of the pilot house from the starboard search light onto the console and from the exhaust stacks onto the electrical components in the engine room on the main engines. Seal opening to prevent water from coming into vessel.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2024
Resolved 28 May 2024
Lifesaving
Issued 2 October 1997
Resolved
Replace ring buoys.
Condition: Unknown
Due 20 October 1997
Resolved 20 October 1997
Accommodation/Occupational Safety
Issued 2 October 1997
Resolved
Remove bunks 2nd deck storage space location.
Condition: Unknown
Due 20 October 1997
Resolved 20 October 1997
Engineering
Issued 2 October 1997
Resolved
Repair/replace flame screens on all fuel vent goosenecks.
Condition: Unknown
Due 20 October 1997
Resolved 20 October 1997
Electrical
Issued 2 October 1997
Resolved
Replace wire connection nuts from 12VDC Nav Light system
Condition: Unknown
Due 20 October 1997
Resolved 20 October 1997
Documentation
Issued 2 October 1997
Resolved
Provide vessel log for bridge watch.
Condition: Unknown
Due 20 October 1997
Resolved 20 October 1997
Navigation
Issued 2 October 1997
Resolved
Update Rules of Road manual with current addition.
Condition: Unknown
Due 20 October 1997
Resolved 20 October 1997