JAMES BRENNAN is a 1967 towing vessel. The Coast Guard has recorded 19 inspections since 1997, most recently in August 2026, along with 13 deficiencies and 1 casualty investigation in 2010.
Records from 1997 to 2026. Most recent: inspection, 6 August 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)61.5 ft × 25.0 ft × 6.2 ft
Registered tonnagegross 122 / net 83
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJ F BRENNAN CO INC · LA CROSSE, WI, UNITED STATES · built 1967
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLA CROSSE, WI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 July 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it122 - Regulatory (Subpart C or D), Gross Ton 83 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1980 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 10 June 2025Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. Remote means to activate valve failed.
*****Corrected on same date******
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 June 2025
Resolution: Cable repaired and performed satisfactorily.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 June 2025Resolved
A towing vessel must carry a combination of day and night visual distress signals. All approved distress signals on board were expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2025
Resolved 18 June 2025
Resolution: New approved flares placed on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 June 2025Resolved
Each towing vessel must carry at least one approved appropriately-sized lifejacket for each person on board. COI authorized 15 persons on board, only 14 lifejackts (approved PFDs) on board.
Code 705: Vessel restricted in authorized persons allowed to be carried on board from 15 to 14.
Action required: 705 - Other - as specified
Resolved 18 June 2025
Resolution: One additional appropriately rated PFD placed on board.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 June 2025Resolved
All portable fire extinguishers must be inspected or tested at least once every 12 months Annual servicing of the extinguisher located near the flammable/combustible products storage cabinet was overdue.
********Corrected*********
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2025
Resolution: Fire extinguisher replaced with one which had been serviced.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 10 June 2025Resolved
All lifesaving equipment must be tested and maintained in accordance with the minimum requirements of § 199.190 of this chapter which states, "Each battery clearly marked with an expiration date and used in an item of survival equipment must be replaced during the annual inspection if the expiration date has passed." The waterlight's battery was expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2025
Resolved 18 June 2025
Resolution: New waterlights for ring buoys installed on vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 June 2025Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Cover plate was missing for outlet under helm console and attached to port bulkhead.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2025
Resolved 18 June 2025
Resolution: Outlet cover installed on outlet.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 14 May 2024Resolved
Electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on-board under normal and emergency conditions. Water is coming in from the top of the pilot house from the starboard search light onto the console and from the exhaust stacks onto the electrical components in the engine room on the main engines. Seal opening to prevent water from coming into vessel.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2024
Resolved 28 May 2024
Lifesaving
Issued 2 October 1997Resolved
Replace ring buoys.
Condition: Unknown
Due 20 October 1997
Resolved 20 October 1997
Accommodation/Occupational Safety
Issued 2 October 1997Resolved
Remove bunks 2nd deck storage space location.
Condition: Unknown
Due 20 October 1997
Resolved 20 October 1997
Engineering
Issued 2 October 1997Resolved
Repair/replace flame screens on all fuel vent goosenecks.
Condition: Unknown
Due 20 October 1997
Resolved 20 October 1997
Electrical
Issued 2 October 1997Resolved
Replace wire connection nuts from 12VDC Nav Light system
Condition: Unknown
Due 20 October 1997
Resolved 20 October 1997
Documentation
Issued 2 October 1997Resolved
Provide vessel log for bridge watch.
Condition: Unknown
Due 20 October 1997
Resolved 20 October 1997
Navigation
Issued 2 October 1997Resolved
Update Rules of Road manual with current addition.
Condition: Unknown
Due 20 October 1997
Resolved 20 October 1997
17 September 2010Routine · role: Involved in a Marine Investigation (non-casualty) · activity 3853464
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.