Records from 2008 to 2026. Most recent: operational control imposed, 26 July 2026.
Inspection history · 35
26 July 2026
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8446947
31 January 2026
COE-Administrative
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8304412
29 July 2025
COC-TVE Renew
Administrative · Activities Europe · Activity 8197181
14 January 2025
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8063670
16 September 2024
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8003551
14 August 2024
COC-TVE Annual
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7974771
29 November 2023
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7831094
30 August 2023
PSC B · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7781005
18 December 2022
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7610683
7 May 2022
PSC B · COC-TVE Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7433935
19 July 2021
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7262510
12 March 2021
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7156376
12 March 2021
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7156918
8 March 2021
PSC B · COC-TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7152456
27 April 2020
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6944517
5 April 2020
COC-TVE Renew · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6933591
7 November 2019
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6850749
23 February 2019
ISPS II Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6627591
2 October 2018
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6553217
1 March 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6363944
27 February 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6362339
21 February 2018
COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6357740
3 August 2017
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6229312
3 August 2017
In-Service Inspection · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6231196
26 March 2017
COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6113062
19 June 2016
ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5899900
29 March 2014
In-Service Inspection · Ballast Water Examination · COC-TVE Annual · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4821235
25 March 2014
ISPS II Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4822601
23 March 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4821336
23 March 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4822859
15 May 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3475922
19 January 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3396654
6 August 2008
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3289064
6 August 2008
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3291314
18 July 2008
Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3267509
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 January 2025
Resolved
The machinery shall be of a design and construction adequate for the service for which they are intended.
Vessel self reported a reduction of propulsion during outbound transit due to mechanical issues.
Cite: 74SOLAS(20)II-1/26.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 January 2025
Resolution: Crew of vessel removed and replaced the ME Unit #5 cracked cylinder head. Main engine operation test was carried out with no issues. Class attest to normal operations.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 14 August 2024
Resolved
In tankers, electrical equipment, cables and wiring shall not be installed in hazardous locations unless it conforms with standards not inferior to those acceptable to the organization. PSCO discovered 12 cracked explosion proof lights in the pump room, with the majority being on the lowest level. Cargo transfer is prohibited until lights are replaced, taken out of service with risk mitigation in place.
74SOLAS(04)II-I/45.11
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2024
Resolution: Received ABS class report attesting to the repair of all lights.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 8 March 2021
Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed a leak in the #1 cargo pump line inside of the pump room from a previous cargo. Cargo pump #1 shall not be used until deficiency is rectified.
74SOLAS(2014 amend)II-2/4.1.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 March 2021
Resolution: Vessel sent in a class surveyor's report stating the cargo pipe line was tightened and tested to 1.5 times MAWP with no leakage indicated.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 April 2020
Resolved
Unavailability of marine chemist due to COVID-19 travel restrictions. Cargo pump room was not inspected by USCG. At next U.S. port call a marine chemist must certify the space and USCG must attend to inspect the cargo pump room.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 6 April 2020
Resolved 27 April 2020
Resolution: There was no deficient item identified during the 05APR20 COC exam.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 2 October 2018
Resolved
Each emergency generating sets shall be capable of being readily started in their cold condition at a temperature of 0 degrees celsius. Vessel's emergency generator failed to start on primary and secondary means during annual classs survey on 1OCT18.
74 SOLAS 2004 Cons II-1/44.1
Action required: 10 - Deficiency Rectified
Due 3 October 2018
Resolved 3 October 2018
Resolution: reviewed class report and tested Emergency Generator with satisfactory results. C/E replaced the power module making the E-gen fully operational.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 21 February 2018
Resolved
1840 - Instrumentation - The electrical measuring system for the Residual Oil Tank is not functioning. Repair measuring system prior to leading cargo. SOLAS 74(a) 2014 cons. I/11)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 February 2018
Resolved 24 February 2018
Resolution: Received class report from ABS clearing this deficiency. Report stated that the Electronic Measuring system for the Residual Oil tank was replaced and is in satisfactorily normal working condition.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 29 March 2014
Resolved
1899-Tankers(Other)-The condition of the ship and its equipment shall be maintained to ensure ship will remain fit to proceed to sea w/o danger to the ship or persons onboard. During testing of Inert Gas analyzer, crew was unable to demonstrate proper test of high or low oxygen alarm. An analyzer failure alarm occurred each time the oxygen was beyond set points. Provide tech report.-SOLAS(09) I/11
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 29 March 2014
Resolved 5 April 2014
Resolution: Received class report from ABS attesting to the proper repairs.
Construction/Loadline › Hull › Hull Plating
Issued 23 March 2014
Resolved
0938 -Hull - Vsl reported a collision with 2 barges at MM 166 in the Mower Mississippi River whil trying to maneuver anchor position. Provide documentaiton from class attesting to the integrity of the ship's hull and adjacent spaces.
-SOLAS 74 am I/11
Action required: 705 - Other - as specified
Due 23 March 2014
Resolved 24 March 2014
Resolution: Received, reviewed and accepted class report from ABS stating there was no damage to the ship noted.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 18 July 2008
Resolved
Vessel unable to produce evidence that the inert gas system has final approval. Last report available on board, report number RO-775240 date 04DEC06, states the system is still pending final approval. Vessel is prohibited from conducting cargo ops until rectified.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 July 2008
Resolved 18 July 2008
Resolution: Received statutory survey report from class attesting to approval of the inert gas system.