Records from 2010 to 2026. Most recent: inspection, 23 July 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 9 July 2026
Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. FCC Emergency Broadcasting placard in the operating station was deteriorated. 46 CFR 184.506/ 16C.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2026
Resolved 10 July 2026
Resolution: A new placard installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 July 2026
Resolved
Each nozzle must be of corrosion-resistant material and be capable of being changed between a solid stream and a spray pattern. The nozzle was fixed of a solid steam, not capable of spray pattern. 46 CFR 181.320 (d)/ 16C
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2026
Resolved 13 July 2026
Resolution: An approved nozzle capbale for making spray and stream was installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 9 July 2026
Resolved
Watertight doors and watertight hatches must be marked on both sides in clearly legible letters at least 1 inch high: “WATERTIGHT HATCH—KEEP CLOSED”. Forward collision bulkhead watertight hatch does not have required markings.46 CFR 185.610/ 16C.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2026
Resolved 15 July 2026
Resolution: Markings installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 9 July 2026
Resolved
Each hatch exposed to the weather must be watertight. Forward collision bulkhead hatch was found leaking profusely, and it was adjusted. However, minimal leak is still present due to faulty rubber gasket. 46 CFR 174.220 (a)/ Code 17/re-classified as 16C.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2026
Resolved 13 July 2026
Resolution: New gasket installed and not leaking.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 July 2026
Resolved
The owner of a vessel must designate a name for the vessel on the Application for Initial Issue, Exchange, or Replacement of Certificate of Documentation; or Redocumentation (form CG-1258) submitted to the Director, National Vessel Documentation Center when the owner elects to change the name of the vessel. The vessel name in the Certificate of Documentation is "LADECIMA" (one word, no space), and the vessel name both in Certificate of Inspection and in the transom is "La Decima" (two words, with space in between). Either correct the vessel name with the NVDC, or correct the vessel name in the transom, and notify USCG Sector San Juan within 14 days of the decision and action taken. 46 CFR 67.111 (a)/ 16C.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2026
Resolved 23 July 2026
Resolution: NVDC processed the vessel name change and now reflects the correct name in two words according with the COI issued in YR2025.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 6 June 2025
Resolved
Each hatch exposed to the weather must be watertight. Hatch cover located in the forward collision bulkhead was found leaking water profusely to the compartment upon testing. 46 CFR 174.220(a) Code 17C.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2025
Resolution: Corrected by adjusting the hatch to make watertight seal.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 June 2025
Resolved
Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crewmember assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. The EAP Placard was not available. 46 CFR 16.401(a). Code 16C.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2025
Resolved 20 June 2025
Resolution: An EAP Placard was installed.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 6 June 2025
Resolved
The name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel. Vessel name is not displayed in port and starboard sides, not in the stern of the vessel. Also, the hailing port is not displayed. 46 CFR 67.123 Code 16C.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2025
Resolved 3 July 2025
Resolution: Corrected
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; Minimize accidental personnel contact with energized parts; and Prevent electrical ignition of flammable vapors. Multiple dead-end wires Engine Room # 2 MDE and underneath the operating station console cabinet. 46 CFR 183.200 Code 16C.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2025
Resolved 20 June 2025
Resolution: Dead-end wires were fixed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 June 2025
Resolved
A self priming, power driven fire pump must be installed on each vessel the fire pump must be capable of both remote operation from the operating station and local operations at the pump. Local controls to start the fire pump located in the steering compartment was found inoperable, and unable to energize the electric fire pump. 46 CFR 181.300 Code 16C.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2025
Resolved 20 June 2025
Resolution: Tested and found fully operational.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 June 2025
Resolved
All observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Two through hole penetrations in the engine room which is a CO2 protected space were found underneath the operating station through cables runs between the deck and the CO2 activation pull cables. 46 CFR 176.830 Code 16C.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2025
Resolved 20 June 2025
Resolution: Sealed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 20 June 2018
Resolved
The shafts, bearings and propellors were pulled.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2022
Resolution: Vessel missed dry dock and annual exams, COI has been deactivated and vessel is not operating. Vessel needs to undergo dry dock and COI exams prior returning for passenger service.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 20 June 2018
Resolved
Certificate of Documentation is expired.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2022
Resolution: Vessel missed dry dock and annual exams, COI has been deactivated and vessel is not operating. Vessel needs to undergo dry dock and COI exams prior returning for passenger service.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 June 2018
Resolved
Radio Certificates (Radio telephony etc.) were expired.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 4 January 2022
Resolution: Vessel missed dry dock and annual exams, COI has been deactivated and vessel is not operating. Vessel needs to undergo dry dock and COI exams prior returning for passenger service.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 June 2018
Resolved
Fire fighting was last inspected in 2016.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2022
Resolution: Vessel missed dry dock and annual exams, COI has been deactivated and vessel is not operating. Vessel needs to undergo dry dock and COI exams prior returning for passenger service.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 June 2018
Resolved
Install metal clamps on the over head wires in the engine room.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 4 January 2022
Resolution: Vessel missed dry dock and annual exams, COI has been deactivated and vessel is not operating. Vessel needs to undergo dry dock and COI exams prior returning for passenger service.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 June 2018
Resolved
Perform battery maintenance (corrosion)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2022
Resolution: Vessel missed dry dock and annual exams, COI has been deactivated and vessel is not operating. Vessel needs to undergo dry dock and COI exams prior returning for passenger service.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 June 2018
Resolved
Update expired medicine in first aid kit.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2022
Resolution: Vessel missed dry dock and annual exams, COI has been deactivated and vessel is not operating. Vessel needs to undergo dry dock and COI exams prior returning for passenger service.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 5 August 2016
Resolved
Replace corroded exhaust riser elbows connected to the turbochargers for both port & stbdside MDEs.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2022
Resolution: Vessel have missed both COI and dry dock exams and is out of service.
Engineering › Bilge Water Management System › Pump
Issued 5 August 2016
Resolved
Prove proper operation of both bilge alarms and bilge pumps.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2022
Resolution: Vessel have missed both COI and dry dock exams and is out of service.
Accommodation/Occupational Safety › Other Accommodation Spaces › Insect Screen
Issued 5 August 2016
Resolved
Clean and sanitize rodent feces found at operating station.
Action required: 705 - Other - as specified
Due 12 August 2016
Resolved 4 January 2022
Resolution: Vessel have missed both COI and dry dock exams and is out of service.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 1 May 2016
Resolved
Vessel must undergo and complete a drydock inspection prior returning for passenger for hire service after missing drydock inspection due on 30APRIL2016.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2016
Resolution: Vessel completed dry dock credit on 31JUL2016.