Records from 2008 to 2026. Most recent: inspection, 10 March 2026.
Inspection history · 23
10 March 2026
Drydock Exam · Annual Inspection · Vessel Attendance · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8318668
5 March 2025
Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8085019
28 February 2024
Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7860842
19 October 2023
Administrative Inspection · Inclining Experiment
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7807331
21 February 2023
Deficiency Check · Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7680217
2 March 2022
Hull Examination · COI Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7407349
24 February 2021
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7145495
10 September 2020
Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7055789
11 May 2020
Deficiency Check · Administrative Inspection · Construction Oversight
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7063586
25 February 2020
Annual Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6916690
25 February 2019
Hull Examination · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6637847
7 September 2018
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6535125
15 July 2018
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6480856
15 July 2018
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6481238
5 March 2018
Deficiency Check · COI Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6370410
7 March 2017
Hull Examination · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6100147
21 October 2016
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6027261
21 October 2016
Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6027285
29 February 2016
Hull Examination · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5836087
10 March 2010
Administrative Inspection · Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3698151
3 March 2010
Hull Examination · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3689329
16 March 2009
In-Service Inspection · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3434232
13 November 2008
Initial Certification · Inclining Experiment · Construction Oversight · Internal Structural Exam · Hull Examination · Welding Related Inspections Qualification Testing
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3309567
Electrical › Electric Generation Source (service) › Power Requirement
Issued 21 October 2016
Resolved
Prove proper operation of power source.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 October 2016
Resolution: Operator proved proper operation of new alternator.
Construction/Loadline › Hull › Hull Plating
Issued 29 February 2016
Resolved
Vessel was found to have wasted area in vicinity of the stbd side engine compartment vent. Issued CG-835 to crop to good metal and renew.
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 1 March 2016
Resolution: Wasted area was cropped out to good metal, renewed with new steel and painted. Approximate area replaced was 3 inches by 8 inches.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 13 November 2008
Resolved
Properly mark vessel's name on hull.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 January 2009
Resolved 30 March 2009
Resolution: Corrected
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 13 November 2008
Resolved
Place onboard required number of adult and childs type I PFDs.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 January 2009
Resolved 30 March 2009
Resolution: Corrected
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 13 November 2008
Resolved
Properly mark vessels name on life rings and all type I PFDs.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 January 2009
Resolved 30 March 2009
Resolution: Corrected
Personnel › Training › Familiarization Training
Issued 13 November 2008
Resolved
Conduct required drills and vessel familiarization with master and crew members.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 January 2009
Resolved 30 March 2009
Resolution: Corrected