RUBY PRINCESS

RUBY PRINCESS is a 2008 passenger vessel (inspected). The Coast Guard has recorded 130 inspections since 2016, most recently in May 2026, along with 40 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 7 May 2026.

Built
2008
Last inspected
7 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 May 2026
…with no type recorded48
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9378462
982126
Flag
BERMUDA
Maury page id
psix-982126

Documentation record

Tonnage as PSIX records it8623 - Dead Weight, Ton
113561 - Convention (Subpart B), Gross Ton
83606 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 3

Inspection history · 130

7 May 2026 Type not recorded
No type recorded · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 8371142
16 February 2026 PSC A · COC-CVE Quarterly
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8309802
11 December 2025 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8285681
1 December 2025 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8278316
13 September 2025 Bulk Liquid Transfer Monitor
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8235060
9 September 2025 Type not recorded
No type recorded · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 8233472
22 August 2025 Bulk Liquid Transfer Monitor
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8227362
17 August 2025 PSC A · Deficiency Check · COC-CVE Annual
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8207678
16 July 2025 MARPOL Annex I Examination · In-Service Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 8188181
8 July 2025 In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8179861
5 February 2025 COC-CVE Quarterly · PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8072976
27 November 2024 In-Service Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8040563
22 August 2024 PSC A · COC-CVE Annual
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7984914
10 May 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7937920
9 May 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7929759
23 April 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7917956
9 March 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7889976
28 February 2024 COC-CVE Quarterly · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7870079
28 February 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7879797
20 February 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7867849
8 February 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7873997
20 December 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7872369
1 October 2023 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7802849
30 September 2023 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7806336
25 August 2023 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7776886
31 July 2023 COC-CVE Annual · Ballast Water Examination · ISPS Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7757332
6 July 2023 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7735250
6 July 2023 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7735323
10 June 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7762630
9 June 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7785712
1 June 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7755095
1 June 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7755101
22 May 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7745256
22 May 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7745260
11 May 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7734363
11 May 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7734370
3 May 2023 COC-CVE Quarterly · PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7674690
30 April 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7726536
28 February 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7643547
4 January 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7616438
30 November 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7602150
15 October 2022 PSC A · COC-CVE Annual
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7576812
13 October 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7577053
24 August 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7542931
9 August 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7529422
23 June 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7519710
21 June 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7483461
15 June 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7478319
9 June 2022 Bulk Liquid Transfer Monitor
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7510896
26 May 2022 In-Service Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7459886
30 April 2022 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7442446
20 April 2022 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7435316
19 April 2022 COC-CVE Quarterly · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7433497
11 April 2022 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7429751
21 March 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7415847
9 March 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7409137
1 March 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7404145
23 February 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7400866
7 November 2021 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7346813
2 November 2021 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7352852
31 October 2021 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7344032
22 October 2021 PSC B · COC-CVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7331915
25 September 2021 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7371309
25 September 2021 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7371593
16 January 2021 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7128203
17 March 2020 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6928035
13 December 2019 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6873475
13 November 2019 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6855213
13 November 2019 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6855243
8 October 2019 Administrative Inspection
Administrative · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 6830917
25 September 2019 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6821025
17 September 2019 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6814037
6 September 2019 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6805707
30 August 2019 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6799259
30 August 2019 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6799266
24 August 2019 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6830108
12 August 2019 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6781244
12 August 2019 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6781254
5 August 2019 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6792851
4 August 2019 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6773796
1 August 2019 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6769976
25 July 2019 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6784596
13 July 2019 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6749558
8 July 2019 Administrative Inspection · In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6759807
27 June 2019 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6727573
16 June 2019 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6715402
13 June 2019 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6732774
27 May 2019 ISPS III Exam · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6673759
23 May 2019 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6692026
20 May 2019 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6690911
19 May 2019 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6755236
18 May 2019 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6690890
8 April 2019 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6658587
26 March 2019 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6649103
19 January 2019 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6613717
22 December 2018 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6604366
17 November 2018 ISPS II Exam · Ballast Water Examination · Deficiency Check · Administrative Inspection · COC-CVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6579994
6 November 2018 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6576549
26 August 2018 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6574854
16 August 2018 Type not recorded
No type recorded · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6561606
4 August 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6500558
15 July 2018 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6521090
27 June 2018 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6507166
21 May 2018 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6421737
7 May 2018 Ballast Water Examination · ISPS III Exam · COC-CVE Quarterly
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6408106
3 May 2018 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6409204
28 April 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6401307
15 March 2018 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6372657
13 March 2018 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6398424
29 November 2017 COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6313642
20 September 2017 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6279985
20 September 2017 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6280563
18 September 2017 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6269837
21 August 2017 In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6243736
8 June 2017 Ballast Water Examination · PII Safety Exam · COC-CVE Quarterly · ISPS II Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6169764
3 June 2017 Bulk Liquid Transfer Monitor
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6165504
24 May 2017 Type not recorded
No type recorded · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6170104
6 May 2017 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6140577
22 December 2016 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6061540
19 November 2016 ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6044344
26 August 2016 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6030426
6 July 2016 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5932104
27 June 2016 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6318131
26 June 2016 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5920010
23 May 2016 COC-CVE Quarterly · PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5884436
8 May 2016 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5871920
17 April 2016 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6314318
12 April 2016 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5852672
29 March 2016 Administrative Inspection · ISPS III Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5842239
14 February 2016 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5825051

Deficiency record · 40

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 August 2025 Resolved
Oil fuel Pipes....If such an additional valve is fitted in the machinery space, it shall be operated from a position outside the space. Quick closing inlet valves on #4 and #5 generator did not close upon activation. 74SOLAS II-2/4.2.2.3.4
Action required: 17 - Rectify deficiencies prior to departure
Due 17 August 2025
Resolved 17 August 2025
Resolution: Valves repaired to satisfaction of attending Marine Inspector
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 17 August 2025 Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. PSCO observed stairwell guides at midship deck 7 were unfamiliar with the duties of their position. SOLAS 20 III/19.2.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 August 2025
Resolved 17 August 2025
Resolution: Training provided to stairwell guides prior to vessel departure.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 February 2025 Resolved
Doors and door frames in "B" class divisions and means of securing them shall provide a method of closure which shall lhave resistance to fire equivalent to that of the divisions. B Class door for crew entry on Deck 11 Zone 3 does not close properly. 74 SOLAS 20 II-2/9.4.1.2.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 5 February 2025
Resolution: Ships crew adjusted door to close correctly.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 February 2025 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, a door designed to re-open upon contacting an object in itss path shall reopen not more than 1m from the point of contact. Sliding FSD 09.7.03 had a crash bar that malfurnctioned and would not reset. 74 SOLAS 20 II-2/9.4.1.1.5.11
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 5 February 2025
Resolution: Adjusted crash bar to reset properly.
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 27 November 2024 Resolved
Following installation, the master, owner, operator, agent, or person in charge of the vessel must properly maintain the BWMS in accordance with all manufacturer specifications. Vessel's ballast water management system is inoperable. Vessel shall not discharge ballast water into U.S. waters. 33 CFR 151.2025(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 December 2024
Resolved 8 December 2024
Resolution: Received technician report attesting to the proper function of the ships BWTS. All SAT.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 August 2024 Resolved
Waste receptacles shall be constructed of non-combustible materials with no openings in the side or bottom. PSCO observed plastic garbage cans or bags containing combustible materials in the main laundry space and the manager office main deck 6 aft. Additionally on the horizon court . PSCO observed garbage stowed on top of the designated container. 74SOLAS20 II-2/4.4.2
Action required: 10 - Deficiency Rectified
Resolved 22 August 2024
Resolution: Plastic garbage cans and bags of garbage and garbage stowed on top of cans removed.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 August 2024 Resolved
Fire doors in main vertical zones bulkhead galley boundries and stairway enclosures shall be self closing. PSCO observed fire screen door 15.1.04, 2.5.03 and 6.1.05 unable to close. 74SOLAS20 II-2/9.4.1.1.5.1
Action required: 10 - Deficiency Rectified
Resolved 22 August 2024
Resolution: All doors were adjusted to self close.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 22 August 2024 Resolved
Manually operated call point complying with the FSS code...shall be readily accessible. PSCO observed manually operated call point 72 by the salty dog grill inoperable. 74SOLAS20 II-2/7.7
Action required: 10 - Deficiency Rectified
Resolved 22 August 2024
Resolution: Call point was repaired and tested.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 August 2024 Resolved
Fire extinguishers shall be situated...that their servicablity is not impaired by the weather vibrations or other external factors. PSCO observed a fire extinguisher by the deck safety work shop stowed without a bracket. 74 SOLAS20 II-2/10.3.2.4
Action required: 10 - Deficiency Rectified
Resolved 22 August 2024
Resolution: The fire extinguisher was properly mounted with bracket.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 22 August 2024 Resolved
Fire protection systems and fire fighting systems and appliances shall be maintained ready for use. PSCO observed a blocked fire extinguisher in store 17207.
Action required: 10 - Deficiency Rectified
Resolved 22 August 2024
Resolution: Obstruction removed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 28 February 2024 Resolved
The following functional requirements shall be met escape routes shall be maintained in a safe condition, clear of obstacles. PSCOs observed deck 5, crew training room emergency exit door failed to open. 74 SOLAS (20) II-2/13.1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2024
Resolution: Received class report and video attesting to the repair of the emergency exit door.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 28 February 2024 Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. PSCOs observed crew members failed to properly start port side rescue boat and were unfamiliar with starting arrangements. 74 SOLAS 20 III/19.2.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2024
Resolution: Crew members were provided training on proper operation of the rescue boat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 28 February 2024 Resolved
The load line ring, lines and letters shall be painted white or yellow on a dark ground or in black on a light ground. They shall also be permanently marked. PSCOs observed STBD side deck line and load line mark were not contrasting color to the hull. ILLC Article 8
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 February 2024
Resolution: STBD side deck line and load line mark were painted in contrasting colors to the hull.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 20 February 2024 Resolved
The administration shall satisfy itself what the general structure strength of the hull is sufficient for the drought corresponding to the free-board assigned. PSCOs were notified by a company representative that on 18Feb2024 the vessel made contact with pier 21 at Port Everglades causing a 5-10cm indentation along with some frame damage on the forward starboard side of the vessel bringing into question if the general structure strength of the hull is sufficient. ICLL 66/88 Annex I / Reg. 1(1)
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 April 2024
Resolution: Received class survery report to attest to the temporary repair of hull.
01 - Certificates & Documentation › 011 - Ships Certificates › International Anti-fouling-System Certificate
Issued 29 August 2023 Resolved
Every crew member with assigned duties shall be familiar with these duties before the voyage begins. Secodn in command for lifeboat # 12 could not demonstrate engaging the engine ahead or astern. Code 17A -> 10C SOLAS 111/19.2.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 August 2023
Resolved 29 August 2023
Resolution: Crewmember was trained
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 August 2023 Resolved
Spaces are classified according to their fire risk shown in catagories (1) to (14). Life machinery space on deck 16, aft is a catagory (10) space where the storage of combustibles is prohibited. PSCO observed the storage of several combustibles. Code 16a, SOLAS 11-2/9.2.2.3.2.2
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2023
Resolved 14 September 2023
Resolution: Class attended and cleared
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 August 2023 Resolved
Safe escape routes shall be provided. In the bell box office, the audible alarm for the room-in-room arrangement did not give an immediate notification in the event of a fire. Code 16a, SOLAS II-2/13.1.1
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2023
Resolved 14 September 2023
Resolution: Class attended and cleared
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 29 August 2023 Resolved
Escape route signs... shall be of photoluminesent material or marked by lighting. In the crew training room, deck 5, zone 7, there were no exit signs for either means of escape. Code 16a, SOLAS II-2/13.3.2.5.1
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2023
Resolved 14 September 2023
Resolution: Class attended and cleared
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 August 2023 Resolved
A fixed fire-fighting system, required by this chapter shall comply with the provisions of the Fire Safety Systems Code. Each section of sprinklers shall include means for giving audible and visual alarm signal automatically at one or more indicating units whenever any spinkler comes into action. When testing section valves 36 & 54, flow switches did not activate on the bridge. FSS Code 8.2.5.2.1. Code 16a, SOLAS II-2/10.4.1.1
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2023
Resolved 14 September 2023
Resolution: Class attended and cleared
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 29 August 2023 Resolved
Escape doors from public spaces that are normally latched shall be fitted with a means of quick release. Such means shall consist of a door-latching mechanism incorporating a device that releases the latch upon the application of a force in the direction of escape flow. Primary means of escape from the gym was unable to be unlocked in the direction of escape IVO MCP 48. Cobe 16a, SOLAS II-2/13.3.2.6.2
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2023
Resolved 14 September 2023
Resolution: Class attended and cleared
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 August 2023 Resolved
For determining the appropriate fire integrity standards to be applied to boundaries between adjacent spaces, such spaces are classified according to their fire risk as shown in the catagories (1) to (14) below. NFPA Code 30 flammable liquid lockers were being used in the salon "chemical locker" and in the Horizon, stbd dishwashing area. The above mentioned lockers should only be used in catagory 11,12, or 14 spaces unless approved to EN11470-1 Type 60 or Type 90. Code 16a, SOLAS II-2/9.2.2.3.2.2.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2023
Resolved 14 September 2023
Resolution: Class attended and cleared
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 29 August 2023 Resolved
Fire-fighting Systems and appliances shall be kept in good working order and readily available for immediate use. A fire station was blocked in club Fusion, deck 6, zone 7 and aft dining room deck 7, zone 7. In addition, in the Hearts and Minds chapel, chairs were blocking a fire hose station. Code 10c, SOLAS II-2/14.2.1.2
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 29 August 2023
Resolved 29 August 2023
Resolution: Items were moved while PSCOs were onboard.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 25 August 2023 Resolved
WHENEVER AN ACCIDENT OCCURS TO A SHIP OR A DEFECT IS DISCOVERED, EITHER OF WHICH AFFECTS THE SAFETY OF THE SHIP, THE MASTER OR OWNER OF THE SHIP SHALL REPORT AT THE EARLIEST OPPORTUNITY TO THE ADMIN, THE NOMINATED SURVEYOR OR RECOGNIZED ORGANIZATION RESPONSIBLE FOR ISSUING THE RELEVANT CERTIFICATE. IF THE SHIP IS IN A PORT OF ANOTHER CONTRACTING GOVERNMENT, THE MASTER SHALL ALSO REPORT IMMEDIATELY TO THE APPROPRIATE AUTHORITIES OF THE PORT STATE. VESSEL HAS EXPERIENCED AN ELECTRICAL FIRE ON LIFTING CRANE ABOVE #5 GENERATOR. VESSEL REP TO PROVIDE REPORT CONTAINING ROOT CAUSE OF SUCH FIRE, AND TO ENSURE PREVENTION OF SUCH FIRE IN ALL OTHER LIFTING CRANE INSTALLATIONS ABOVE OTHER SUCH GENERATORS. 74 SOLAS (20) I/11.C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 September 2023
Resolved 30 August 2023
Resolution: Received cause analysis report from the vessel.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 31 July 2023 Resolved
The following functional requirements shall be met: escape routes shall be maintained in a safe condition, clear of obstacles. A laundry cart and a shelf of coveralls were observed IVO FSD 2.4.06 impeding the means of escape. In addition, IVO FSD 16.7.01, several pantry items were being stowed impeding the means of escape. Futhermore, on deck 4 amidships, IVO embarkation deck, plastic hotel service carts were being stowed in the passenger stair tower. CODE 10c, SOLAS II-2/13/1/2
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 29 August 2023
Resolved 29 August 2023
Resolution: PSCOs observed items removed.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 6 July 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed large inset and penetration of the hull on the port quarter. Damage is located above the waterline and is the result of the ship's allision with Piear 27 during mooring operations. 74 SOLAS (20) I/11(a) Code 60ac 02106
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 July 2023
Resolution: Class and USCG team visually inspected repairs and were found satisfactory. Final class survey report will be attached once received.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 15 October 2022 Resolved
The emergency source of electrical power shall be capable, for a period of 36 hours: emergency lighting in alleyways, stairways, and exits. Emergency light located near the exit of the Skywalker Room was inoperable. 74 SOLAS 04 II-1/42.2.1.3
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 15 October 2022
Resolved 15 October 2022
Resolution: Crew replaced light prior to the end of the exam.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 April 2022 Resolved
Openings in bulkheads and decks in passenger ships shall have means of securing them and shall provide a method of closure which shall have resistance to fire equivalent to that of the divisions. PSCO discovered a B-15 fire door in crew laundry on deck 04 next to cabin P04101 and B-15 fire door on deck 03 of crew laundry did not properly close. 74 SOLAS 20 II-2/9.4
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 April 2022
Resolution: Vessel corrected doors before team departed (10c).
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 22 October 2021 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Multiple installed ampules for hi-fog heads in spa treatment rooms had depleted fluid levels. 74 SOLAS (20) II-2/14.2.1.2
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 October 2021
Resolution: Vessel replaced defective sprinklers.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 October 2021 Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirement shall be met: means shall be provided to control leaks of flammable liquids. #4 lube oil purifier had excessive leaks. 74 SOLAS (04) II-2/4.1.1
Action required: 10 - Deficiency Rectified
Resolved 22 October 2021
Resolution: Repaired on-site.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 27 May 2019 Resolved
Emergency lighting for mustering and abandonment shall be tested at each abandon ship drill. The emergency lighting was not energized for the abandon ship drill. - 74 SOLAS (14) III/19.3.4.8
Action required: 10 - Deficiency Rectified
Resolved 27 May 2019
Resolution: At the prompting of the CG examiner, e-lighting was energized toward conclusion of abandon ship drill.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 27 May 2019 Resolved
The Company should establish programs for drills and exercises to prepare for emergency actions. The company's procedures for abandon ship drills do not include energizing the emergency lighting. - 74 SOLAS (14) IX/3.1, ISM 8.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 June 2019
Resolved 16 June 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 27 May 2019 Resolved
During preparation and launching, the survival craft, launching appliance, and the area into which it is to be launched shall be adequately illuminated by lighting supplied from the emergency source of electrical power. 11 emergency lights are burnt out. - 74 SOLAS (04) III/16.7
Action required: 10 - Deficiency Rectified
Resolved 27 May 2019
Resolution: All lights restored to functional condition.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 27 May 2019 Resolved
Above the bulkhead deck there shall be at least two means of escape from each restricted space or group of spaces. Bosun locker has been subdivided with a locked gate dividing the primary and secondary escape routes. - 74 SOLAS (04) II-2/13.3.2.2
Action required: 10 - Deficiency Rectified
Resolved 27 May 2019
Resolution: Locked removed pending revision of escape/evacuation plan.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 27 May 2019 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including fire resistant divisions and protection of openings and penetrations in these division. Power-operated sliding fire door at starboard side deck 7 theater fails to open under power. - 74 SOLAS (14) II-2/14.2.1.1.1
Action required: 10 - Deficiency Rectified
Resolved 27 May 2019
Resolution: Door repaired and re-tested in presence of CGMIs.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 17 November 2018 Resolved
74SOLAS(14) III/21.1.3 All survival craft required to provide for abandonment by the total number of persons on-board shall be capable of being launched with their full compement of persons and equipment within a period of 30 min from the time the abandon ship signal is given after all persons have been assembled, with life jackets donned. PSCOs unable to witness lowering and maneuvering of lifeboats due to bunkering operations. Lifeboat drills are to be conducted in next U.S. Port.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 17 November 2018
Resolved 29 November 2018
Resolution: Vessel submitted video recording attesting to the lowering of starboard side lifeboats. all satisfactory.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 17 November 2018 Resolved
74SOLAS(04) II-1/45.1.3 All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCOs found two dead end wires in the deck 16 starbaord forward sanctuary.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 17 November 2018
Resolved 17 November 2018
Resolution: Deficiency rectified to the satisfaction of the attending PSCO.
Personnel › Training › Proficiency in Survival Craft
Issued 7 May 2018 Resolved
01 - 2025 - Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Three lifeboat crews and rescue boat crew were not familiar with assigned duties/resposibilities on their respective survival craft. - 74 SOLAS (2014) III/19.2.1 - 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2018
Resolved 21 May 2018
Resolution: Returned to vessel and quizzed crews. All sat.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 7 May 2018 Resolved
02 - 0915 - In addition to the emergency lighting required by regulations II-1/41 and III/11.5, the means of escape, indlucing stairways and exits, shall be marked by lighting or photoluminescent strip indicators placed not more than 300 mm above the deck at all points of the escape route, including angles and intersections. Main escape route through deck 4, zone 6 is misssing low location lighting. - 74 SOLAS (2009)II-2/13.3.2.5.1 - 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 21 May 2018
Resolution: Low-location lighting (PL system) installed.
Engineering › Electric Propulsion System › Conductor
Issued 15 March 2018 Resolved
[name withheld] reports vessel has lost 01 of 04 converters on the stbd prop shaft reducing shaft speed to 70%.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 April 2018
Resolved 3 April 2018
Resolution: Fault on power converter rectified. Class issued documentation deleting their previous condition of class.
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 21 August 2017 Resolved
The ship's side shall not have any openings between the embarkation station of the marine evacuation system and the waterline in the lightest seagoing condition and means shall be be provided to protect the system from any projections. MES installations on the port and starboard side are located above side shell openings and the vessel has no flag exemption or equivalency to permit the installatio
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 September 2017
Resolved 18 September 2017
Resolution: Equivalency permitting arrangement received from Flag and conditions examined by CG marine inspector found satisfactory.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.