Records from 2008 to 2026. Most recent: inspection, 30 March 2026.
Documentation record
Registered dimensions (L × B × D)93.0 ft × 40.0 ft × 22.2 ft
Registered tonnagegross 194 / net 132
ITC dimensions (L × B × D)93.0 ft × 40.0 ft × 22.2 ft
ITC tonnagegross 414 / net 124
BuilderNICHOLS BROS BOAT BUILDERS INC · FREELAND, WA, UNITED STATES · built 2007
Hull materialSteel
PropulsionDiesel
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 17 August 2026 · expires 31 August 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it132 - Regulatory (Subpart C or D), Net Ton
124 - Convention (Subpart B), Net Ton
194 - Regulatory (Subpart C or D), Gross Ton
414 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 17
30 March 2026
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8332604
15 May 2025
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8136575
1 April 2025
Drydock Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8098959
19 December 2024
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8049067
8 April 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7883199
9 November 2023
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7822931
6 July 2023
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7735323
11 May 2023
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7685637
16 March 2022
Internal Structural Exam · Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7408058
24 November 2019
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6863285
8 November 2014
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5022141
21 January 2014
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4789736
20 May 2013
Administration
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4596187
14 January 2012
Damage Survey
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 4224884
13 January 2012
Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 4234786
29 December 2009
MTSA Verification
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 3656546
21 October 2008
MTSA Verification
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 3349061
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 May 2025
Resolved
Each towing vessel must have a fire-detection system installed to detect engine room fires. The owner or managing operator must ensure the system is installed, tested, and maintained in accordance with the manufacturer's design manual. 02 heat detectors in the z drive room were found to not properly mounted. Correct to the satisfaction of MI.
46 CFR 142.330(a)(2)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2025
Resolved 2 June 2025
Resolution: Received satisfactory photo of corrected deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 May 2025
Resolved
A 40-B portable fire extinguisher must be located near the storage room or cabinet. This is in addition to the portable fire extinguishers required by tables 142.230(a) and 142.230(b) of this part. Missing portable fire extinguisher in the vicinity of the paint locker on board, correct to the satisfaction of MI.
46 CFR 142.225(d)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2025
Resolved 2 June 2025
Resolution: Received satisfactory photo of corrected deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 May 2025
Resolved
Each lifebuoy on a towing vessel must:Be marked in block capital letters with the name of the vessel. Life buoys on board found to have deteriorated markings or no markings on the life buoys, correct to the satisfaction of MI.
46 CFR 141.360(b)(4)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2025
Resolved 2 June 2025
Resolution: Received satisfactory photo of corrected deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 May 2025
Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. Wire nuts found on the STBD day tank sight glass sensor, correct to the satisfaction of MI.
46 CFR 143.400(e)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2025
Resolved 2 June 2025
Resolution: Received satisfactory photo of corrected deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 15 May 2025
Resolved
Essential systems or equipment must be regularly tested and examined. Tests and examinations must verify that the system or equipment functions as designed. If a component is found unsatisfactory, it must be repaired or replaced. Test and examination procedures must be in accordance with manufacturer's instructions. MI discovered pressure relief devices on both Port and STBD air receivers to be installed incorrectly as per instructions.
46 CFR 143.245(a)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2025
Resolved 2 June 2025
Resolution: Received satisfactory photo of corrected deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 December 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessel reported loss of propulsion on starboard engine. Provide root cause analysis of propulsion system issue, provide technician report for MI review, and conduct sea trial to MI satisfaction.
46 CFR 143.205(a)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2025
Resolution: Vessel ordered OEM Shaft. Tech Disassembled shaft and installed original Pinion Gear with new bearings on shaft. Installed Pinion Shaft in Upper Box and set backlash and pattern to factory specs. Conducted satisfactory sea trails.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 8 April 2024
Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. Crew member did not have medical certificate onboard vessel.
46 CFR 10.301(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2024
Resolved 13 August 2024
Resolution: Verified valid medical certificate
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 8 April 2024
Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Railing on top of pilot house was loose. Repair prior to next credit drydock.
46 CFR 144.800 (a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2025
Resolved 1 April 2025
Resolution: ABS verified completion of railing repairs during third party annual survey.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 11 May 2023
Resolved
Each towing vessel operating in oceans and coastwise services must have line throwing appliances approved under approval series 160.040. Four rocket projectiles, each complete with bridle and leader of fire-resistant materials. Vessel was missing three rocket projectiles.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2023
Resolved 16 June 2023
Resolution: Operator placed line throwing devices onboard.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 11 May 2023
Resolved
Each escape hatch and emergency exit used as means of escape must be marked on both sides in clearly legible letters "EMERGENCY EXIT, KEEP CLEAR". Forward emergency escape missing emergency exit label.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2023
Resolved 30 May 2023
Resolution: Operator labeled fwd escape hatch.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 March 2022
Resolved
All fixed fire-extinguishing systems, including machinery shutdowns on board vessel must be tested atleast once every 12 months. Vessels automatic shutdowns were not tested during annual CO2 fixed fire fighting inspection by Global Fire. Vessel shall obtain appropriate documentation from approved servicing company of successful operation of automatic shutdowns and forward report to OCMI for approval.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 April 2022
Resolution: Vessel obtained appropriate documentation from approved servicing company of successful operation of automatic shutdowns. Test SAT.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 March 2022
Resolved
A towing vessel that is certified for limited coastwise, coastwise, oceans route must be equipped with both an approved 160-B semi-portable fire extinguishing system
and a fixed fire extinguishing system installed to protect the engine room. Vessel is missing their Semi-portable fire extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 April 2022
Resolution: Semi-Portable Fire extinguisher replaced and serviced.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 16 March 2022
Resolved
The total relieving capacity of such relief valves must
prevent pressure from exceeding the MAWP. Relief valves
on air receivers did not relieve at or below the MAWP.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2022
Resolved 18 April 2022
Resolution: Replaced and test new relief valves. Test SAT
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 March 2022
Resolved
Each life ring must be marked with type I retro-
reflective material. STBD deck life ring was missing a piece of retro-reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2022
Resolved 12 April 2022
Resolution: Replaced retro.