Records from 2009 to 2025. Most recent: inspection, 2 October 2025.
Inspection history · 26
2 October 2025
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8245024
26 January 2025
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8070027
26 January 2025
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8071236
14 October 2024
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8019478
16 September 2024
COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7995063
29 April 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7901571
4 December 2023
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7833587
2 March 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7644485
2 March 2023
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7644613
12 January 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7620277
1 January 2023
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7614665
30 December 2022
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7614495
28 September 2022
Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7567831
2 November 2021
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7344324
18 December 2020
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7113616
24 November 2019
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6863285
2 October 2019
COI Inspection · Administrative Inspection · Deficiency Check · Initial Certification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6826833
2 October 2019
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6835720
22 August 2018
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6522669
13 July 2018
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6502110
10 April 2018
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6391906
25 July 2016
Industry Initiated Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5953522
17 July 2013
Industry Initiated Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4656000
23 March 2010
Industry Initiated Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3724934
2 February 2010
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3676205
24 August 2009
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3576296
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 October 2025
Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. Engine P200 panel in aft engine room not adequately labeled. 46 CFR 143.400 (d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2025
Resolved 15 October 2025
Resolution: Received picture of updated labeling.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 October 2025
Resolved
Electrical systems and equipment… minimize… shock hazards. Electrical panel in aft z-drive room missing closure devices, allowing for exposed electrical equipment. 46 CFR 143.400 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2025
Resolved 15 October 2025
Resolution: Received picture of new closure devices for panel.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 October 2025
Resolved
Electrical systems and equipment… minimize… shock hazards. Dead end wires on battery charger next to centerline generator not properly secured. 46 CFR 143.400 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2025
Resolved 15 October 2025
Resolution: Received picture of properly terminated wires.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 2 October 2025
Resolved
Each liferaft must be stowed to permit manual release from its securing arrangements. Pins used to secure and release life raft launching appliance found seized; implement periodic inspections on system to ensure readiness.
46 CFR 199.130 (c)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2025
Resolved 15 October 2025
Resolution: Received updated monthly safety equipment inspection form with launching appliance added to it.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 October 2025
Resolved
The transfer procedures required by § 155.720 must be: Permanently posted or available at a place where the procedures can be easily seen and used by members of the crew when engaged in transfer operations. Fuel transfer procedures not posted or available in the E/R or near the fuel transfer manifold. 33 CFR 155.740 (c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2025
Resolved 15 October 2025
Resolution: Received picture of fuel transfer procedure at fueling station.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 January 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessel experienced partial loss of power on their starboard engine. Starboard engine RPM's drop to idle, vessel needed to de-clutch then clutch back in to regain engine RPM's. Conduct repairs, provide tech report, and conduct sea trials to the satisfaction of the MI.
46 CFR 143.205(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 January 2025
Resolution: Operator provided technician report and conducted satisfactory sea trials.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 16 September 2024
Resolved
Each survival craft must be stowed— So as not to require lifting from its stowed position in order to launch, except that— A survival craft that weights 185 kilograms (407.8 pounds) or less may be lifted not more than 300 millimeters (1 foot) in order to launch. In addition to the requirements of paragraph (a) of this section, each liferaft must be stowed as follows: Each liferaft must be arranged to permit it to drop into the water from the deck on which it is stowed. A liferaft stowage arrangements meets this requirement if it— (i) Is outboard of the rail or bulwark;(ii) Is on stanchions or on a platform adjacent to the rail or bulwark; or (iii) Has a gate or other suitable opening large enough to allow the liferaft to be pushed directly overboard and, if the liferaft is intended to be available for use on either side of the vessel, such gate or opening is provided on each side of the vessel. Vessel's liferaft was located so that it must be lifted more than 1 foot to launch. In addition, vessel's liferaft was not stowed to permit it to drop into the water from the deck on which it is stowed. Modify liferaft stowage to the satisfaction of the MI.
46 CFR 141.310
46 CFR 199.130 (a)(7)(ii) & (c)(3)
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2024
Resolved 17 October 2024
Resolution: Attended vessel to verify satisfactory arrangement of liferaft stowage.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 16 September 2024
Resolved
Every towing vessel equipped with an inflatable survival craft must have, in conspicuous places near each inflatable survival craft, approved placards or other posted instructions for launching and inflating inflatable survival craft. The vessel's liferaft did not have launching instructions posted near the liferaft. Add instructions in conspicuous location to the satisfaction of the MI.
46 CFR 141.320
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2024
Resolved 22 October 2024
Resolution: Received pictures of posted instructions.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 December 2023
Resolved
Each towing vessel must have either a self-priming, power-driven, fixed fire pump, a fire main, and hoses and nozzles; or a portable pump, and hoses and nozzles. Vessel's fixed fire pump was leaking from the shaft seal at approximately 2 cups per minute. Portable fire pump placed onboard.
46 CFR 142.325
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 December 2023
Resolved 16 January 2024
Resolution: Repairs and verified on site.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 4 December 2023
Resolved
Each towing vessel operating in oceans and coastwise service must have a line throwing appliance approved under approval series 160.040. Four rocket projectiles, each complete with bridle and leader of fire-resistant materials. Vessel only have two rocket projectiles onboard.
46 CFR 141.385
46 CFR 160.040-4(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 December 2023
Resolved 19 December 2023
Resolution: Verified installation of all line throwing devices onboard.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 March 2023
Resolved
A vessel must be operated in accordance with applicable laws and regulations in such a manner as to afford protection against hazards to life, property, and the environment. Vessel experienced a fire in the stbd exhaust stack during operations. Determine cause of the fire and make repairs to the satisfaction of the attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 22 March 2023
Resolution: Sea trial conducted. Lagging reduced to visually identify repair.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 January 2023
Resolved
A vessel that is exposed to salt water more than 6 months in any 12 month period since the last examination or initial certification must undergo a drydock and internal structural examination at least twice every 5 years, with not more than 36 months between examinations. Vessel has not conducted required drydock examination.
46 CFR 137.700(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2023
Resolution: Drydock exam was completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 December 2022
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. The vessel's starboard generator was inoperable. All repairs to be conducted to the satisfaction of the OCMI.
46 CFR 143.400(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 30 December 2022
Resolution: Rectified on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 30 December 2022
Resolved
Each towing vessel operating in regions north of lat. 32° N. must carry at least one approropriate-size immersion suit, approved under approval series 160.171, for each person onboard. The vessel was missing one immersion suit and one was not properly serviced. The vessel is limited to carry 6 total persons onboard.
46 CFR 141.350(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 January 2023
Resolved 2 February 2023
Resolution: Verified in person.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 December 2022
Resolved
Fixed fire-extinguishing systems must be inspected and tested, as required by table 142.240 of this section, in addition to the tests required by 147.60 and 147.65 of subchapter N of this chapter. Owner/operator to provide evidence of satisfactory servicing of the fixed fire-extinguishing system to the cognizant OCMI.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 January 2023
Resolved 3 February 2023
Resolution: Received renewed fire certification for the vessel's fixed fire extinguishing system.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 30 December 2022
Resolved
When operating a vessel on a body of water where the discharge of untreated sewage is prohibited by the EPA, the operator must secure each Type III device in a manner which prevents discharge of sewage. Securing device was not found for the vessel's marine sanitation device.
33 CFR 159.7(c)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 January 2023
Resolved 2 February 2023
Resolution: Verified in person.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 30 December 2022
Resolved
Each towing vessel operating in oceans and coastwise service must have a line throwing appliance approved under the approval series 160.040. The vessel's line throwing device has been expired, and is restricted to limited coastwise operations.
46 CFR 141.385
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 January 2023
Resolved 2 February 2023
Resolution: Verified in person.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 December 2022
Resolved
Verify that the vessel's crew conducted abandon ship and man overboard drills under simulated emergency conditions. Underway portion of exam was not conducted.
46 CFR 137.220(g)(9)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 January 2023
Resolved 2 February 2023
Resolution: U/w portion of inspection conducted.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 December 2021
Resolved
Emergency lighting sources must provide for sufficient illumination under emergency conditions and must be automatic, battery-operated with a duration of no less than 2 hours. Emergency lighting not operable for three locations in galley/crew accommodations and one location below deck in crew vestibule. 46 CFR 143.410(b)(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2022
Resolution: Verified emergency egress lighting is operational for entire vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 4 November 2021
Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. Vessel liferaft discovered past due for required annual servicing. 46 CFR 141.230
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 December 2021
Resolution: Verified liferaft properly serviced.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 4 November 2021
Resolved
Each towing vessel operating north of lat. 32deg N must carry the number of immersion suits as prescribed in this paragraph. Vessel identified only 6 immersion suits on board, whereas COI requires 8 immersion suits for route.
46 CFR 141.350(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 December 2021
Resolution: Verified all required immersion suits on board and in satisfactory condition.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 4 November 2021
Resolved
Propulsion machinery, including main engines must be maintained to ensure proper operation. Discovered exhaust leaks IVO turbochargers for all main engines and generators.
46 CFR 143.205(c)(1)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 December 2021
Resolution: Verified no exhaust leaks for the main engines and generators.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 4 November 2021
Resolved
Pressure vessels must be equipped with one or more spring-loaded relief valves. The total relieving capacity of such relief valves must prevent pressure from exceeding the MAWP. Pressure vessel relief valves discovered rated at 275 psi whereas MAWP is stamped at 250 psi.
46 CFR 143.300(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 November 2021
Resolved 13 December 2021
Resolution: Verified port and stbd relief valves replaced with satisfactory operational tests conducted.
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 4 November 2021
Resolved
All seals must be properly maintained to prevent leaks of flammable or combustible liquid. Hydraulic leak discovered on port z-drive inboard rotation actuator.
46 CFR 143.220(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 November 2021
Resolved 13 December 2021
Resolution: Verified hydraulic leak no longer an issue for the port z-drive inboard rotation actuator.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 November 2021
Resolved
Each integral fuel tank must have a vent that is fitted with a 30x30 mesh corrosion-resistant flame screen. Vent pipe for 5S 6C f/o tanks missing mesh flame screen and vent pipe for 6S 7S 7C f/o tanks missing two screws to secure flame screen.
46 CFR 143.265(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 November 2021
Resolved 13 December 2021
Resolution: Verified two noted vent pipe screens fully replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 4 November 2021
Resolved
A record of the type, size, and service of each towline, face wire, and spring line, used to make the towing vessel fast to her tow, must be available to the Coast Guard for review. The following minimum information is required in the record: The dates when exams were performed, the identification of each item of towing gear examined, and the name(s) of the person(s) conducting the exams. Vessel unable to provide towing gear maintenance records/logs.
46 CFR 140.820(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 November 2021
Resolved 13 December 2021
Resolution: Verified required maintenance records/logs on board and available for towing gear.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 November 2021
Resolved
Machinery must be designed to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Crew unable to properly line up bilge suction line; require simple instructions posted in vicinity of system for easy access.
46 CFR 143.205(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 November 2021
Resolved 13 December 2021
Resolution: Verified bilge operating instructions posted for future bilge operations.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 4 November 2021
Resolved
Each towing vessel must carry on board and maintain the following: U.S. Coast Guard Light List, River-current tables, Tide tables, and U.S. Coast Pilot. Vessel unable to provide copies of Light List, Coast Pilot, or Tide/current tables.
46 CFR 140.705(a) and 33 CFR 164.72(b)(2)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2021
Resolved 13 December 2021
Resolution: Verified all required publications on board electronically.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 November 2021
Resolved
Each lifejacket must be marked in block capital letters with the name of the vessel and have a whistle secured by a cord to the lifejacket. Discovered three lifejackets missing whistles and four lifejackets missing stenciled name.
46 CFR 141.340(f)(1) and (g)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 November 2021
Resolved 4 November 2021
Resolution: Corrected on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 30 December 2020
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid into the machinery space. Discovered leak on the port engine access cover for front gear case due to bad gasket.
46 CFR 143.220(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 January 2021
Resolved 28 January 2021
Resolution: Received electronic documentation noting repaired leak with upgraded o-ring.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 30 December 2020
Resolved
Verify that all hazardous situations are corrected, with all protective devices in satisfactory condition. Discovered worn, loose, and missing lagging from chillwater system in the engine room.
46 CFR 137.220(l)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 January 2021
Resolved 28 January 2021
Resolution: Received photo documentation of repaired lagging.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 30 December 2020
Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b). Vessel was not performing required tests within the outlined frequencies (I.e.: Weekly, at least once every 3 months, etc.).
46 CFR 143.245(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 January 2021
Resolved 28 January 2021
Resolution: Received electronic documentation of upgraded checksheets for required weekly, monthly, annual testing.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 December 2020
Resolved
On the front compartment of each work vest there shall be stenciled in waterproof ink "WORK VEST ONLY." Discovered work vests not stenciled with required lettering.
46 CFR 140.430(a) and 46 CFR 160.053-5(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 January 2021
Resolved 28 January 2021
Resolution: Received photo documentation of properly stenciled work vests.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 2 October 2019
Resolved
Each EPIRB must be tested monthly. Vessel did not have records of monthly EPIRB tests. Test and record EPIRB on a monthly basis.
46 CFR 199.190
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2019
Resolved 4 November 2019
Resolution: EPIRB entry added to monthly testing log
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 2 October 2019
Resolved
Vessels on Oceans route are required to carry 6 day and 6 night visual distress signals. Vessel had onboard 4 hand flares, 2 parachute, and 2 smoke. Provide required number of visual distress signals onboard.
46 CFR 141.370
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2019
Resolved 4 November 2019
Resolution: Verified proper number of distress signals onboard