Records from 2008 to 2025. Most recent: inspection, 9 June 2025.
Inspection history · 29
9 June 2025
PSC B · Deficiency Check · COC-CHEM & TVE Renew
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8150246
23 June 2021
PSC B · Administrative Inspection · COC-CHEM & TVE Renew
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7233513
28 March 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7164023
8 January 2021
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7121648
1 August 2020
PSC B · COC-CHEM & TVE Annual
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7020739
17 May 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6954590
10 April 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6937783
1 July 2019
COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6732495
29 March 2019
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6652198
26 March 2019
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6649659
27 June 2018
COC-CHEM Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6457753
1 May 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6403917
22 January 2018
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6341582
6 September 2017
COE-Offshore
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6260657
29 August 2017
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6254679
9 June 2017
Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6164850
7 December 2016
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6054111
1 December 2016
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6051925
29 November 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6049008
20 April 2016
Deficiency Check · ISPS II Exam · COE-Offshore · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 5858251
15 April 2016
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5855308
10 December 2011
Ballast Water Examination · COC-CHEM Annual · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4201807
9 December 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4201821
7 December 2011
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4203957
11 July 2011
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4077993
9 November 2010
COC-CHEM Renew · Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3887205
11 February 2010
COC-CHEM Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3678640
10 February 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3679031
19 September 2008
MARPOL Annex V Examination · COC-CHEM Renew · Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3326926
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 9 June 2025
Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations. Lifeboat weekly checks per vessels SMS included checks for proper cooling of the engine. PSCO observed both lifeboats with empty coolant reservoirs (see def#3). Weekly check last completed was signed "Found Satisfactory" by engineers(ETO). SOLAS 74 (2020) IX/3.1 ISM Code 10.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2025
Resolution: Vessel provided proof of training conducted 10JUN2025 for proper weekly lifeboat inspection procedures.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 9 June 2025
Resolved
If there is a valid international load line certificate on board the ship, such control shall be limited to the purpose of determining that: the position of the load line of the ship corresponds with the certificate. PSCO observed a different load line on hull. Vessel's master confirmed operation under a load line certificate that included TF, F, and W load lines. Only S and T were observed on the hull. ICLL 66, Article 21
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 June 2025
Resolution: Vessel updated the permanent marking on the hull to match the correct load line certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 9 June 2025
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Cooling reservoirs on both starboard and portside lifeboats were empty. Coolant was found in bilges of both lifeboats. J/W pump on STBD lifeboat damaged. 74 SOLAS(2020) III/20.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2025
Resolution: Vessel crew replaced damaged equipment and refilled cooling reservoirs. Vessel ran STBD Lifeboat for 5 mins with PSCOs in attendance with no issues.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo ship safety equipment (including exemption)
Issued 9 June 2025
Resolved
The certificates referred to in this regulation shall be issued or endorsed either by the administration or by any person or organization authorized by it. Cargo ship safety equipment and cargo ship safety construction certificates were not properly endorsed. Place and signature fields were empty. 74 SOLAS (2020) I/12(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2025
Resolved 13 June 2025
Resolution: Vessel sent copies of properly endorsed certificates, to include place and signature fields filled out.
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 9 June 2025
Resolved
Such certificate (IOPP) shall be endorsed as appropriate by organization only authorized by it. IOPP was not properly endorsed. Place and signature fields were empty. MARPOL I/7
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2025
Resolved 13 June 2025
Resolution: Vessel sent copies of properly endorsed certificates, to include place and signature fields filled out.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 2 July 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform to the provisions of the present
regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Crew witnessed leak in main hydraulic line and reported same to the Coast Guard. Complete repairs to hydraulic line prior to commencing cargo discharge operations. SOLAS 74 (2004 Cons) I/ 11
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 2 July 2021
Resolved 3 July 2021
Resolution: Repaired temporarily to the satisfaction of class.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 23 June 2021
Resolved
The inert gas system shall be capable of inerting, purging and gas-freeing empty tanks and maintaining the atmosphere in cargo tanks with the required oxygen content. There is a crack in the jacket water cooling for the IGG burner, making the system inoperable. Repairs must be completed prior to conducting cargo operations.
Condition: Design Flaw
Action required: 60 - Rectify deficiencies prior to movement
Resolved 30 June 2021
10 - Safety of Navigation › N/A - No Subsystem › Pilot ladders and hoist/pilot transfer arrangements
Issued 8 January 2021
Resolved
Arrangements shall be provided to enable the pilot to embark and disembark safely on either side of the ship. Vessel was observed with a pilot arrangement that was not assembeled as constructed and which may have been a danger to those embarking or disembarking. 74 SOLAS (2004) V/23.3.1
Action required: 60 - Rectify deficiencies prior to movement
Due 10 January 2021
Resolved 10 January 2021
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 1 July 2019
Resolved
After any survey of the ship under regulations 7, 8, 9, or 10, has been completed, no change shall be made in the structural arrangements, machinery equipment and other items covered by the survey, without the sanction of the administration. During inspection, PSCO identified a space behind the engine control room not listed on the fire control plan.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 August 2019
Resolution: Recieved class report
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 1 July 2019
Resolved
The ring, lines, and letters shall be painted in white or yellow on a dark ground or in black on a ligh groun. The shall also be permanently marked on the sides of the ships to the satisfaction of the administration. PSCO's found current load line to no be properly painted.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 August 2019
Resolution: recieved class report
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 20 April 2016
Resolved
Vsl must complete hydrostatic test of cargo lines at 150% MAWP annually or as part of biennial insp.Vsl has not conducted test since Aug13 at last drydock.Vsl is restricted to 8bar discharge pressure during offload of cargo in COTP DelBay.Required test must be completed prior to conducting cargo ops in U.S. after sailing frgn 33CFR156.170 40c
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 November 2016
Resolution: Received reports attesting to the proper testing of the cargo and slop lines.