Documentation record
Registered dimensions (L × B × D)56.0 ft × 22.0 ft × 8.6 ft
Registered tonnagegross 106 / net 72
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderVINTON SHIPBUILDING & REPAIR INC · VINTON, LA, UNITED STATES · built 1982
Hull materialSteel
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHOUMA, LA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 19 May 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it106 - Regulatory (Subpart C or D), Gross Ton
72 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 40 inspections, each with its date, unit and type; 17 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 19 other vessels inspected with it; 3 other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 40
2 June 2025
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8150415
13 June 2024
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7934187
23 February 2024
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7869348
16 February 2024
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7900702
2 May 2023
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7679316
15 November 2022
COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7594682
19 July 2022
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7512854
27 April 2022
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7439195
29 March 2022
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7420977
8 March 2022
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7407931
26 September 2018
Type not recorded
No type recorded · Station Port OConnor · USCG Heartland District (CGD-H) · Activity 6550316
17 October 2012
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4470496
6 April 2011
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3980287
4 November 2010
Industry Initiated Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3885393
10 February 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3679031
14 September 2009
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3595482
13 August 2009
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3565149
15 January 2009
Administration
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3394863
20 December 2007
Deficiency Check · MTSA Verification · Uninspected Other
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3118686
18 December 2007
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3118170
3 December 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3108768
15 March 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2888744
14 July 2006
MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2712346
23 March 2006
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2608026
13 January 2006
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2572349
6 January 2004
Security Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1976881
17 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1966217
21 September 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 50735
13 February 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 287435
13 February 2001
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 1522364
8 January 2001
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 1522330
10 October 2000
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 50056
24 August 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 394710
9 June 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 151499
3 October 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 80188
22 September 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 166249
25 January 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 125938
5 August 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 57184
4 July 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 81274
2 April 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 138290
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 June 2025
Resolved
There was a leak in the packing of the tail shaft.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 June 2025
Resolved 16 July 2025
Resolution: Tail shaft was tightened so that there is not so much leaaking.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 June 2025
Resolved
There was excessive oily water in the bilge.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 26 June 2025
Resolved 16 June 2025
Resolution: The bilge was cleaned out.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 June 2025
Resolved
Vessel missed their 90 day window for their annual.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 5 June 2025
Resolved 5 June 2025
Resolution: Vessel applied to recieve a new COI.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 February 2024
Resolved
46 CFR 137.200 A towing vessel subject to this subchapter and choosing the Coast Guard inspection option, or required to have the Coast Guard inspection option, must undergo an annual inspection within 3 months before or after the COI anniversary date.
-Vessel has not undergo an annual inspection with in 3 months of anniversary date. (16NOV22).
Action required: 60 - Rectify deficiencies prior to movement
Due 23 March 2024
Resolved 27 February 2024
Resolution: Vsl complete COI. COI issued with new anniversary date 26FEB24.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 15 November 2022
Resolved
A fire pump must be capable of: (1) Delivering water simultaneously from the two highest hydrants, or from both branches of the fitting if the highest hydrant has a Siamese fitting, at a pitot-tube pressure of at least 344 kilopascals (kPa) (50 pounds per square inch (psi)), and a flow rate of at least 300 liters per minute (lpm) (80 gallons per minute (gpm)). Fire pump was at 40 psi, repair as original.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 November 2022
Resolved 6 December 2022
Resolution: Replaced the fire pump and performed an op test. Pump operated at 70 psi.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 15 November 2022
Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. Vessel master did not have a medical certificate upon inspection. Provide proof of medical record.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 30 November 2022
Resolved 6 December 2022
Resolution: Master provided proof of medical record upon reinspection of their credential.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 November 2022
Resolved
Each lifejacket must be marked:
With Type I retro-reflective material approved under approval series 164.018. The arrangement of the retro-reflective material must meet IMO Resolution A.658(16) (incorporated by reference, see § 136.112 of this subchapter). Reflective tape was painted over on one vest.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 November 2022
Resolved 6 December 2022
Resolution: Reflective tape was replaced on the lifejacket.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 15 November 2022
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. Engine room vents did not have covers to stop/close system.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 30 November 2022
Resolved 6 December 2022
Resolution: Vent covers were fabricated and placed on all vents in the vessel. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 November 2022
Resolved
Carriage requirement. A towing vessel must carry a combination of day and night visual distress signals indicated in Table 141.370 of § 141.370 for specified areas where the vessel operates. 02 flares require replacement.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 November 2022
Resolved 6 December 2022
Resolution: Added the 02 flares that were missing to the vessel. All required distress signals sat.
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 15 November 2022
Resolved
Towing vessels must be equipped with the following equipment, as applicable to the area of operation:
(a) Fathometer (except Western Rivers). Vessel did not have a fathometer installed on board.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 30 November 2022
Resolved 6 December 2022
Resolution: Vessel installed a new fathometer and performed a function test. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 15 November 2022
Resolved
Each liferaft or group of liferafts must be arranged for float-free launching. A hydrostatic release unit used in a float-free arrangement must be approved under approval series 160.162. No hydrostatic release was attached, add as required.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 30 November 2022
Resolved 6 December 2022
Resolution: Hydrostatic release/weak link was attached to the life raft. All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 July 2022
Resolved
All owners and operators of an existing towing vessel must have onboard a valid COI prior to the specified phase-in period. This vessel has not scheduled an inspection or obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection immediately and the vessel may no longer be permitted to operate.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 19 July 2022
Resolved 2 May 2023
Resolution: COI issued to the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 March 2022
Resolved
Replaced batthery charger wiring and test battery charger upon completion.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2022
Resolved 8 March 2022
Resolution: Replaced cable and tested batthery charger to ensure operation.
Lifesaving › Buoyant Apparatus › Marking
Issued 20 December 2007
Resolved
Vessel must stencil all life rings with vessel name.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 December 2007
Resolved 21 December 2007
Resolution: life ring stenciled
Navigation › Collision/Grounding Avoidance › Radar
Issued 18 December 2007
Resolved
Vessel must have radar repaired by certified technician and repair report faxed to MSU Galveston.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2007
Resolution: Received fax of technicians report stating that the antenna motor assist was damaged and replaced it with new working assist. Radar has been tests and works satisfactorily.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 18 December 2007
Resolved
Vessel D.A.P.I representative must provide copies of drug and alcohol testing of crew members on board and verification of company employee screenings in accordance with 46 CFR 16.230 and 46 CFR 16.260 for 1 year. Documentation must be faxed or mailed to Marine Safety Unit Galveston - no later than close of business Friday 21 Dec 2007.
Action required: 705 - Other - as specified
Due 21 December 2007
Resolved 21 December 2007
Resolution: Received statement on DAPI.
Fire Fighting › Remote Fuel Shutoff › General
Issued 18 December 2007
Resolved
Vessel must stencil fuel shut-off and fire pumps on main deck external bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 December 2007
Resolved 21 December 2007
Resolution: stenciled shut offs