Records from 1984 to 2009. Most recent: inspection, 22 April 2009.
Inspection history · 73
22 April 2009
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3458194
22 April 2009
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3458206
23 July 2008
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3276807
11 June 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2958513
3 April 2007
Internal Structural Exam · Hull Examination · Annual Inspection · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2900986
20 October 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2804640
25 May 2006
MARPOL Annex I Examination · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2653279
27 September 2005
SIP Initial Entry
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2580960
14 September 2005
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2492273
29 March 2005
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2322575
16 December 2004
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2260406
16 December 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2263065
10 November 2004
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2239121
9 September 2004
MTSA/ISPS Verification · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2190663
3 September 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2233716
3 March 2004
Internal Structural Exam · Cargo Tank Internal · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2026829
29 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1970955
2 September 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1894346
26 May 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1819046
27 October 2002
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1714310
27 August 2002
Annual Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1667125
11 July 2002
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1644449
7 June 2002
Hull Examination · COI Inspection · Construction Oversight
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1627833
22 April 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1607748
26 July 2001
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461429
10 May 2001
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1064294
10 February 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1046220
6 August 1999
Type not recorded
No type recorded · CGC POINT SAL · USCG Heartland District (CGD-H) · Activity 1509500
29 April 1999
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1127043
7 April 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 787628
9 March 1999
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1415140
13 February 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1111800
11 February 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1111105
4 January 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 784041
14 April 1997
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1096694
18 March 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1418100
13 February 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1097565
27 August 1996
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1416361
15 July 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 34014
12 July 1996
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1413015
18 June 1996
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1090232
9 June 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 151499
9 June 1996
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1189025
13 February 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1451042
19 September 1995
Damage Survey · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 875222
18 September 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 39011
14 March 1995
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1390010
13 July 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 159769
13 July 1994
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1176943
14 February 1994
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1373984
19 September 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 73016
27 April 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 680003
19 March 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 115575
26 February 1993
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1362706
27 March 1992
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1262309
4 February 1992
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1268729
23 January 1992
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 961126
26 August 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 937814
31 July 1991
Hull Examination · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1247558
14 February 1991
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1227073
10 May 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1227001
29 March 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1230920
30 January 1990
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1236882
17 February 1989
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1044669
31 January 1989
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1350967
4 February 1988
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1329485
7 August 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1337655
20 February 1987
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1009783
22 December 1986
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1027237
5 August 1986
Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1315007
6 February 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 993727
27 February 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1286472
17 February 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1279119
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 16 December 2004
Resolved
Proceed directly to Quality Ship Yard Houma, LA. to make permanent repairs to side shell port side and port side bow bull works. Make repairs to life raft launching brackets and life ring launching device. Renew one smoke canister and float light.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 January 2005
Resolved 21 December 2004
Resolution: Made permanent repairs.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 9 September 2004
Resolved
Provide updated Fire Control Plan and Safety Equipment Plans for review and approval by attending C.G. Marine Inspector, IAW 46 CFR 127.110(a)(3).
Action required: 705 - Other - as specified
Due 10 November 2004
Resolved 10 November 2004
Resolution: Ship checked new Fire Control and Safety Plan, all sat.
Engineering › Diesel Engine (auxiliary)
Issued 2 September 2003
Resolved
Provide proof of over speed device operation for both generators. LEGACY COMPONENT DESC: Over speed Device
Action required: 705 - Other - as specified
Due 2 October 2003
Resolved 24 September 2003
Engineering › Diesel Engine (auxiliary) › Governor
Issued 2 September 2003
Resolved
Provide proof of port liquid mud prime mover emergency shutdown operation.
Action required: 705 - Other - as specified
Due 2 October 2003
Resolved 24 September 2003
Engineering › Fuel Oil Service System
Issued 2 September 2003
Resolved
Provide steel plugs for all Raycor fuel filters. LEGACY COMPONENT DESC: Filter
Action required: 705 - Other - as specified
Due 2 October 2003
Resolved 2 September 2003
Lifesaving › Embarkation Appliances/Stations
Issued 2 September 2003
Resolved
Provide stokes litter. LEGACY COMPONENT DESC: Stokes Litter
Action required: 17 - Rectify deficiencies prior to departure
Due 2 October 2003
Resolved 2 September 2003
Fire Fighting › Portable Foam Applicators
Issued 2 September 2003
Resolved
Provide portable foam applicator for the carriage of Marine Portable Tanks. LEGACY COMPONENT DESC: Foam Applicator
Action required: 705 - Other - as specified
Due 2 October 2003
Resolved 2 September 2003
Documentation › Markings/Placards
Issued 2 September 2003
Resolved
Provide SOLAS markings for EEBD's and Fireman's Outfits. LEGACY COMPONENT DESC: SOLAS Markings
Action required: 705 - Other - as specified
Due 2 October 2003
Resolved 2 September 2003
Operations/Management › Drills/Instruction › Safety Orientation
Issued 2 September 2003
Resolved
Provide proper donning placards for all staterooms.
Action required: 705 - Other - as specified
Due 2 October 2003
Resolved 2 September 2003
Fire Fighting › Firemans Outfit
Issued 2 September 2003
Resolved
Provide flashlight for 01-deck firemen's outfit. LEGACY COMPONENT DESC: Flashlight
Action required: 705 - Other - as specified
Due 2 October 2003
Resolved 2 September 2003
Engineering › Steering Gear System
Issued 7 June 2002
Resolved
Provide operational rudder angle indicator in port Z-drive space and demonstrate to the satisfaction of teh attending marine inspector. LEGACY COMPONENT DESC: Rudder Angle Indicator
Action required: 705 - Other - as specified
Due 21 June 2002
Resolved 11 July 2002
Resolution: Cleared item 2 issued 14 June 02 by MSFO. Received service report indicating the starboard rudder angle indicator had been repaired by properly seating the servo motor in the housing and eliminating interferance of the disc with the housing cover.
Operations/Management › Vessel Safety Management
Issued 7 June 2002
Resolved
Provide automation test procedures for approval. LEGACY COMPONENT DESC: Maintenance of Ship/Equipment
Due 30 September 2002
Resolved 16 December 2002
Resolution: Reviewed & approved per approval letter of Dec16, 2002.
Lifesaving
Issued 7 April 1999
Resolved
DEMONSTRATE COMPLIANCE WITH 8TH COAST GUARD DISTRICT'S POLICY LETTER "RESCUE BOAT REQUIREMENTS ON OFFSHORE SUPPLY VESSELS" DATED 12NOV98 TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 7 May 1999
Resolved 3 May 1999
Lifesaving
Issued 9 March 1999
Resolved
INSTALL SUITABLE RESCUE BOAT OR EQUIVILANT IAW EIGHTH DISTRICT POLICY LETTER DATED 12 NOV 99.
Condition: Unknown
Due 7 May 1999
Resolved 7 April 1999
Lifesaving
Issued 18 March 1997
Resolved
INSTALL LIFERAFT LAUNCHING AIDS TO THE SATISFACTION OF THE ATTENDING MARINEINSPECTOR.
Condition: Unknown
Due 18 March 1997
Resolved 18 March 1997
Construction/Loadline
Issued 12 July 1996
Resolved
PROCEED DIRECTLY TO ENSCO DOCK IN BERWICK, LA TO ARRIVE NLT 13JUL96. CONTACT MSO MORGAN CITY ON 15JUL96 AND AFFECT REPAIRS TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR. VESSEL'S DECK CARGO IS TO BE UNLOADEDPRIOR TO TRANSIT. NO M AND O WORK TO BE CONDUCTED. TRANSIT ICW ONLY.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Construction/Loadline
Issued 9 June 1996
Resolved
Proceed to Morgan City S/Y to make permanent repairs to stbd sideshell and chain locker internal framing. Notify USCG when vessel has entered shipyardfor repairs. 12JUN:Proceed to Allied S/Y in Larose to make the above listedrepairs due to unavailability of Morgan City S/Y.
Condition: Unknown
Due 9 June 1996
Resolved 9 June 1996
Fire Fighting
Issued 23 January 1992
Resolved
PROVIDE PROPER SECURING DEVICES AT PORT ENGINE ROOM AND STARBOARD MAIN DECKFIRE STATIONS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 February 1992
Resolved 12 February 1992
Fire Fighting
Issued 23 January 1992
Resolved
PROVIDE SECURING CHAINS ON INSERTS OF FIRE NOZZLES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 February 1992
Resolved 12 February 1992
Accommodation/Occupational Safety
Issued 23 January 1992
Resolved
RENEW DEAD COVER TO PORT LIGHT IN PORT LOUNGE AREA._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 February 1992
Resolved 12 February 1992
Deck/Cargo
Issued 23 January 1992
Resolved
REPLACE MISSING PORT ANCHOR AND NECESSARY CHAIN._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 February 1992
Resolved 12 February 1992
Engineering
Issued 23 January 1992
Resolved
PROVIDE PROPER TUBES IN PORT AND STARBOARD ENGINE ROOM FUEL OIL SIGHT GLASSES._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 February 1992
Resolved 12 February 1992
Documentation
Issued 23 January 1992
Resolved
PROVIDE COAST GUARD APPROVED SAFETY EQUIPMENT PLAN._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1992
Resolved 23 January 1992
Navigation
Issued 23 January 1992
Resolved
PROVIDE CURRENT DEVIATION TABLE OR PROVE DEVIATION TABLE DATED 1989 IS ACCURATE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 February 1992
Resolved 12 February 1992
Deck/Cargo
Issued 14 February 1991
Resolved
CLEAN AND CERTIFY GAS FREE ALL DRY BULK (P-TANKS 1-4) RECEIVERS AS REQUIREDBY 46 CFR 54.01-16 AND CIDIG MEMO NO. 15 AT NEXT CREDIT DRYDOCK (DUE 31JAN92).
Condition: Unknown
Due 14 February 1991
Resolved 14 February 1991
Lifesaving
Issued 30 January 1990
Resolved
RING BOUY ON MAIN DECK REQUIRES A LIGHT. FOR A TOTAL OF THREE RING BOUYS WITH LIGHTS.
Condition: Unknown
Due 30 January 1990
Resolved 30 January 1990
Engineering
Issued 30 January 1990
Resolved
HYDRO TEST ALL FUEL TRANSFER HOSES AND STENCIL DATE AND TEST PSI ON HOSES
Condition: Unknown
Due 30 January 1990
Resolved 30 January 1990
Electrical
Issued 30 January 1990
Resolved
CIRCUIT BOX ON STARBOARD SIDE OF BRIDGE REQUIRE BLANKS.
Condition: Unknown
Due 30 January 1990
Resolved 30 January 1990
Fire Fighting
Issued 30 January 1990
Resolved
REPLACE FIRE HOSE IN COMPANION WAY, FOR A TOTAL OF FIVE GOOD FIRE HOSES.
Condition: Unknown
Due 30 January 1990
Resolved 30 January 1990
Documentation
Issued 30 January 1990
Resolved
PROVIDE AND HAVE ON BOARD 2 COPIES OF THE " THE LAWS GOVERNING MARINE INSPECTION".
Condition: Unknown
Due 30 January 1990
Resolved 30 January 1990
Documentation
Issued 30 January 1990
Resolved
PROVIDE AND HAVE ON BOARD AN ENDORSED LOAD LINE CERTIFIACTE.
Condition: Unknown
Due 30 January 1990
Resolved 30 January 1990