Records from 2014 to 2026. Most recent: inspection, 11 March 2026.
Inspection history · 79
11 March 2026
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8324873
8 December 2025
Periodic Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8280172
20 November 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8271571
23 October 2025
Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8258036
28 August 2025
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8215069
17 April 2025
Periodic Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8112184
17 April 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8113314
20 March 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8097269
16 January 2025
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8064845
31 October 2024
COI Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8026118
2 July 2024
Administrative Inspection · Vessel Attendance · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7947433
8 May 2024
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7909374
22 January 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7852998
11 January 2024
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7847942
21 November 2023
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8070622
13 November 2023
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7823785
12 November 2023
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7832432
2 November 2023
Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7821140
26 September 2023
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7798435
27 July 2023
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7768127
13 July 2023
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7745243
15 June 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7741115
31 March 2023
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7661479
9 March 2023
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7648559
12 January 2023
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7622009
20 October 2022
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7581749
15 September 2022
MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7559964
19 August 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7538459
16 August 2022
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7536533
18 May 2022
Drydock Exam · Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7454747
19 April 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7434227
19 January 2022
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7382723
24 November 2021
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7357323
28 October 2021
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7323014
22 September 2021
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7318583
16 September 2021
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7323134
2 September 2021
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7303722
2 August 2021
Periodic Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7275154
20 May 2021
MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7205555
24 March 2021
Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7161426
26 January 2021
Examination of Repairs · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7131357
5 November 2020
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7088529
30 September 2020
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7068998
31 August 2020
MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7047016
29 April 2020
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6945817
17 March 2020
Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6927983
3 March 2020
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6913133
26 February 2020
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6916421
11 December 2019
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6872220
9 December 2019
Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6870245
24 October 2019
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6842009
3 September 2019
Administrative Inspection · Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6802891
29 July 2019
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6766793
8 July 2019
In-Service Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6741596
14 June 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6713815
8 April 2019
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6658464
14 March 2019
MTSA Verification · Re-Inspection · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6636866
3 December 2018
Examination of Repairs · Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6629583
21 November 2018
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6655529
30 October 2018
MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6579275
9 August 2018
In-Service Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6506354
30 July 2018
Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6496016
10 July 2018
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6604341
4 April 2018
Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6436723
4 January 2018
MTSA Verification · Administrative Inspection · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6331701
14 July 2017
Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6209259
15 June 2017
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6178647
30 April 2017
Security Breach, Potential
Type not classified · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6137118
1 April 2017
Security Breach, Potential
Type not classified · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6117551
13 March 2017
Security Breach, Potential
Type not classified · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6117437
8 March 2017
MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6100332
15 December 2016
COI Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6054070
2 November 2016
MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6034016
15 July 2016
MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5945398
21 June 2016
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5914882
13 May 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5908699
5 April 2016
MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5847951
14 March 2016
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5837810
28 January 2016
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5805217
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 12 March 2026
No resolution recorded
Cylinders must always be secured and when not in use, they must be stowed in a rack in an upright position, with the valve protection cap in place. MI discovered 7 cylinders not properly stowed in the #1 engine room.
46 CFR 147.60 b 1 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2026 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 12 March 2026
No resolution recorded
Gears, couplings, flywheel and all machinery capable of injuring personnel shall be provided with adequate covers or guards. The number 2 engine room has a long section of exposed high speed shaft, running directly next to the MDE.
46 CFR 58.01-20 50C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2026 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 March 2026
No resolution recorded
All electrical appliances shall be suitably installed for the location and service. MI found 1 extension cord being used as a permanent installation of a treadmill and another extension cord running below the deck plates in the number 2 engine room. 46 CFR 111.77-3 50C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2026 — due date passed with no resolution recorded
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 20 November 2025
Resolved
Each self-propelled vessel, except as provided in paragraph (d) of this section, must have an electric or mechanical engine order telegraph system from the navigating bridge to the engineroom. Vessel's engine order telegraph is misreading current status of engines to the pilothouse. Vessel to repair engine order telegraph to accurately display status of engines.
Due 4 December 2025
Resolved 8 December 2025
Resolution: Equipment all satisfactory on quarterly inspection.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 March 2025
Resolved
Carbon dioxide cylinders forming part of a fixed fire extinguishing system must be retested at least every 12 years. Vessels cylinders were due in January 2025. Cylinders must be retested per regulatory cite.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2025
Resolved 24 March 2025
Resolution: New cylinders and flexable hoses purchased and placed into service.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 November 2024
No resolution recorded
In the event of alternations involving the safety of the vessel, the applicable plans shall be submitted for approval. Plan review serial number E2-2403278 shall be re-submitted to MSC after rectifying the general comments number 1-6 as described in response letter dated 6SEP2024.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2024 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 November 2023
Resolved
No repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment shall be made without the knowledge of the OCMI. Vessel reported their #3 SSDG was inoperable due to a failed mounting bolt for their speed sensor. Make permanent repairs w/in 7 days.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 November 2023
Resolved 2 November 2023
Resolution: Received report from the operator that the sensor was correctly mounted and load tested. All sat.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 15 June 2023
Resolved
PA system speakers notably quiet on the main car deck.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2023
Resolved 20 July 2023
Resolution: Port Engineer arranged for technician to attend the vessel to adjust volume of pre-recorded safety announcement and conduct further sound checks on PA system. MIs verified the announcement was reasonably audible throughout the vessel during qtrly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 March 2023
Resolved
Vessel control systems and other miscellaneous systems and equipment must be suitable for the purposes intended. Vessel reports #1 turbocharger condemned and in need of replacement. Replace turbocharger and return system to full operation and conduct testing to assess functionality, submit proof to the CG.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2023
Resolved 10 March 2023
Resolution: Submitted Chief Engineer report via email. See documents.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 24 February 2022
Resolved
Crew not able to change vessel's navigational status in AIS.
33 CFR 164.46(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2022
Resolved 24 February 2022
Resolution: Crew demonstrated correct way to change vessel's navigation status in AIS.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 22 September 2021
Resolved
#1 steering hatch is inoperable, dog is broken and hatch is stuck in the closed position. Welder to come after the 23SEP21 ferry runs. Notify this office if unable to repair hatch before the morning run on 24SEP21.
46 CFR 170.270
Action required: 705 - Other - as specified
Due 24 September 2021
Resolved 24 September 2021
Resolution: Cause of the failure was determined to have been a bolt had backed out of the hatch hand wheel causing the quick acting mechanism to be stuck in the closed position. WSF drilled the hatch disengaging the quick acting mechanism and opened the hatch. The
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 24 March 2021
Resolved
Vessel is required to maintain the plans found in 46CFR91.55-5. The fire control plan located on the bridge was Revision E and the Fire Control Plan located in the ECR is Revision D. Vessel needs to post the most current Revision throughout vessel. 46CFR91.55-1(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2021
Resolved 26 March 2021
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 March 2021
Resolved
The integrity of any deck in way of a stairway opening, other than a stair-tower, shall be maintained by means of "A"or"B" class bulkheads and doors at one level. The integrity of the stair-tower shall be maintained by "A" Class self-closing door. 02 of the FSD did not properly close. 46CFR92.07-10(d)4
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2021
Resolved 26 March 2021
10 - Safety of Navigation › N/A - No Subsystem › Compass correction log
Issued 24 March 2021
Resolved
Each vessel must have a current magnetic compass deviation table or graph or compass comparison record for the steering compass, in the wheelhouse. The vessel's deviation table has not been updated in over 5 years. 33CFR164.35(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2021
Resolved 4 May 2021
Resolution: Vessel had a vendor conduct magnetic compass adjustment.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 5 November 2020
Resolved
While conducting the weight test of the #1 rescue boat, the crew was unable to operate the winch due to activation of the slewing limit switch. The crew was unfamiliar and unable to operate the davit. The master directed the mate to go below and assist the crew, along with an Eagle Harbor tech, which they then manually slewed out the rescue boat in order to re-energize the davit. Update the FAST Manual (Unit 4.3 KDT/Olympics) to reflect proper operations of the davit and how to troubleshoot if this situation recurs. An option would be to create a video that illustrates the nuances of the davit, winch, falls, and limit switches (there was discussion on board to mark slewing limit switch range).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2020
Resolved 2 August 2021
Resolution: FAST manual states operation, SMS states how to submit repair order and notify Port Engineer to complete proper notifications.
05 - Radio Communications › N/A - No Subsystem › Radio log (diary)
Issued 5 November 2020
Resolved
Digital Selective Calling (DSC) is required to be tested weekly and written in the station log. Upon closer inspection, there was some confusion with which radio on each bridge was the designated DSC radio. Clearly identify which radio is the DSC capable radio and ensure all bridge personnel are aware and properly trained with the function/operation of the DSC test. Make weekly DSC entries in the station log.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2020
Resolved 11 February 2021
Resolution: [name withheld] provided photo of January 2021 radio log.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 November 2020
Resolved
The life jacket stowage positions must be marked with the words "life jackets" or "child life jackets" as appropriate or with the appropriate symbol from IMO Resolution A.760(18). The adult and child life jackets located in the life jacket lockers on the Texas Deck were missing this signage.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2020
Resolved 11 February 2021
Resolution: [name withheld] provided photo of sign on life jacket locker.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 November 2020
Resolved
All magnetically controlled fire doors shall be operated locally and by the remote control... FSD 082, 059, 054, and 031 did not operate or close.
Action required: 10 - Deficiency Rectified
Resolved 5 November 2020
11 - Life Saving Appliances › N/A - No Subsystem › Marine Evacuation System
Issued 29 April 2020
Resolved
46 CFR 199.190(k)/705c - 120 DAY EXTENSION FOR SHIP-SIDE DEPLOYMENT OF A MARINE EVACUATION SYSTEM GRANTED, IN ACCORDANCE WITH MSIB 09-20 AND IN CONSIDERATION OF THE DISTRICT 13 EXEMPTION GRANTED BY OCMI LETTER DATED 30 SEPTEMBER 2019. 120 DAY EXTENSION GRANTED BASED ON PREVIOUS DUE DATE OF 2 JUNE 2020. A SHIP-SIDE DEPLOYMENT OF A MARINE EVACUATION SYSTEM MUST OCCUR ON OR BEFORE 30 SEPTEMBER 2020.
Action required: 705 - Other - as specified
Due 30 September 2020
Resolved 30 September 2020
Resolution: Shipboard deployment of MES on 30Sep2020 observed by CG MIs.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 March 2020
Resolved
Required alarms in high ambient noise areas must be supplemented by a visual means. Alarm light for EDG overcrank alarm did not activate locally with alarm.
46 CFR 62.25-20(d)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 November 2020
Resolution: verified alarm activates locally.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 March 2020
Resolved
Test procedure documents must be in a step-by-step or checkoff list format and specify the procedure to be followed. The test procedure for EDG overcrank alarm did not reflect crew practices.
46 CFR 61.40-10
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 November 2020
Resolution: New procedure implemented and being followed.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 3 March 2020
Resolved
Each general emergency alarm signal must be marked. Visual alarm signal in EDG Room not marked.
46 CFR 113.25-20(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 March 2020
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 March 2020
Resolved
Each fire hydrant shall be identified in red letters & figures at least 2 inches high. Fire station no. 4 was not labeled.
46 CFR 78.41-20
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 March 2020
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 9 December 2019
Resolved
Doors, other than those which are normally locked, such as from staterooms, fan rooms, lockers, etc., shall be of the self-closing type capable of closing against a 3 1/2 degree list. FSD 44 does not fully close when released. Keep door closed at all times until the door is repaired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2020
Resolved 11 December 2019
Resolution: Door was adjusted by ships crew
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 9 December 2019
Resolved
Doors, other than those which are normally locked, such as from staterooms, fan rooms, lockers, etc., shall be of the self-closing type capable of closing against a 3 1/2 degree list. FSD 76 does not latch closed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2019
Resolved 11 December 2019
Resolution: Door was adjusted by ships crew
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 9 December 2019
Resolved
Doors, other than those which are normally locked, such as from staterooms, fan rooms, lockers, etc., shall be of the self-closing type capable of closing against a 3 1/2 degree list. FSD 70 does not fully close and latch.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2019
Resolved 11 December 2019
Resolution: Door was adjusted by ships crew
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 September 2019
Resolved
Fire screen door 059 did not close automatically upon activation from pilothouse or local control. 46 CFR 72.05-25 (a)(8)(i)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 September 2019
Resolved 10 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 September 2019
Resolved
04 lifebuoys found in deteriorated condition. 46 CFR 199.190 (a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 September 2019
Resolved 10 September 2019
10 - Safety of Navigation › N/A - No Subsystem › Navigation records
Issued 10 September 2019
Resolved
Local notice to mariners found to not be the most current revision. 46 CFR 78.05-5 (e)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 10 September 2019
Resolved 10 September 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 September 2019
Resolved
Multiple exterior fire station placards found to be unreadable due to UV exposure. 46 CFR 78.47-20 (a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2019
Resolved 6 November 2019
Resolution: Placards replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 June 2019
Resolved
Boiler at #2 engine room was past due on their mounting inspectgion.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2019
Resolved 8 July 2019
Resolution: Completed in inspection activity 6741596.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 8 April 2019
Resolved
All vital systems are required to be operable from the emergency source of power (46 CFR 112.15-5(r)). The CPP and Auxiliary Cooling Pumps are vital systems and are not connected to the emergency bus. The emergency power system must be modified to meet 46 CFR 112.15-5(r) at the vessel's next drydock.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 June 2019
Resolved 29 July 2019
Resolution: Deficiency rescinded. Vital System loads are not required by 112.15-5(r), only vital system automation loads. CPP pumps are vital system loads.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 4 January 2018
Resolved
Replace inoperative emergency lighting bulb in #2 electronic distribution room on the #2 end.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 January 2018
Resolved 5 January 2018
Resolution: Light bulb replaced.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 4 January 2018
Resolved
Replace inoperative emergency lighting bulb in the head of the ships (mates) office.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 January 2018
Resolved 5 January 2018
Resolution: Emergency light bulb replaced.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 4 January 2018
Resolved
Replace inoperative emergency lighting bulb in #1 electronic distribution room on the #1 end.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 January 2018
Resolved 5 January 2018
Resolution: Emergency lightbulb replaced.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 4 January 2018
Resolved
Replace inoperative emergency lighting bulb in #2 end crew quarters toilet room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 January 2018
Resolved 5 January 2018
Resolution: Emergency light bulb replaced.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 4 January 2018
Resolved
Fire screen door #031 is inoperative. Repair door to full capability. Repair prior to carrying passengers or keep closed at all times.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 January 2018
Resolved 5 January 2018
Resolution: Fire screen door technician repaired door to full capability, notification received by Port Eng [name withheld].
Engineering › Steering Gear System › Pump
Issued 4 January 2018
Resolved
CPP service pumps do not alarm upon auto change over. Provide CPP pump auto change-over alarm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2018
Resolved 24 October 2019
Resolution: Witnessed installed CPP pump auto-change alarms, sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Automatic Heat Detectors
Issued 4 January 2018
Resolved
Emergency generator room CO2 heat actuation device not working. Restore system function.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2018
Resolved 5 January 2018
Resolution: HAD wasn't being tested with enough heat, upon recommendation from [name withheld] HAD is now fully functional.
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 15 December 2016
Resolved
Loss of fuel oil alarm on boiler not operational.
Action required: 705 - Other - as specified
Due 15 January 2017
Resolved 20 December 2016
Resolution: ASME CF-450 does not require low pressure alarms for burners where the pump is integral with the burner motor shaft. The unit is provided with an over pressurization shutdown which was tested satisfactorily. All sat.
Engineering › Fuel Oil Service System › Hose
Issued 15 December 2016
Resolved
Replace fuel hose on #2 generator due to water intrusion/rust from chaffing.
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 15 December 2016
Resolution: Crew replaced hose & added chaffing gear.
Stability › Watertight Integrity › General
Issued 15 December 2016
Resolved
Replace gasket on emergency hatch in #2 tank room.
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 15 December 2016
Resolution: Crew replaced gasket.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 21 June 2016
Resolved
Vessel had a failure of freeboard measuring device. Until sensor is replaced freebord measurements must be taken manually twice daily.
Action required: 705 - Other - as specified
Resolved 15 December 2016
Resolution: Tested sat during COI