Records from 1994 to 2025. Most recent: inspection, 11 July 2025.
Inspection history · 28
11 July 2025
Annual Inspection · MTSA Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8185532
16 May 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7913455
22 March 2024
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7884522
14 June 2023
Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7714833
12 July 2022
Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7504409
9 June 2022
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7472762
6 June 2022
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7503381
1 July 2021
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7240953
21 January 2021
Deficiency Check · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7128369
26 August 2020
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7043038
30 April 2020
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6945000
16 May 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6688313
11 April 2019
Initial Certification · Administrative Inspection · MTSA Verification · DAPI Audit · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6657856
16 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6514008
24 July 2017
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6222403
13 March 2017
Administration
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6173950
6 December 2010
Inclining Experiment
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3905534
16 December 2009
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3651262
6 July 2009
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3618125
20 February 2004
Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2016980
20 July 2002
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1649294
12 June 2002
Type not recorded
No type recorded · USCGC PADRE (WPB 1328) · USCG Southeast District (CGD-SE) · Activity 1643450
4 July 1998
Permit to Proceed
Administrative · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 795340
10 September 1996
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 441841
8 June 1996
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 131345
7 October 1994
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 644493
4 October 1994
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 480428
4 October 1994
Uninspected Towing Vessel
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1398140
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 July 2025
Resolved
Prior to Commercial Operation nothing in this subpart limits the marine inspector from conducting any tests or inspections he or she deems necessary to be assured of the vessel's seaworthiness or fitness for its route and service. Vessel unable to conduct steering test, operate main engines and conduct drills. Attending MI must observe steering test, main engines operating properly, and conduct drills prior to operation. - 46 CFR 137.200(d) - 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 August 2025
Resolution: Conducted satisfactory fire and man overboard drills.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 14 July 2025
Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. Gasket was found to be worn, compromising watertight integrity. Replace gasket of watertight hatch located near service winch. - 46 CFR 140.610(b) - 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 August 2025
Resolution: Verified renewed gasket.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 14 July 2025
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following. All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Inspector observed excessive accumulation of oil and oily water in the bilge. Remove oily water from the bilge. - 46 CFR 142.220(a) - 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 August 2025
Resolution: verified all Machinery space bilges were free of oil and the oil/water observed during initial inspection was offloaded by regulated facility.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 July 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. The Aft generator starting battery was observed to be unmounted and unsecured. Secure. - 46 CFR 143.205(a) - 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 August 2025
Resolution: verified battery mount installed properly.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 July 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Main Engine air filters found to be heavily soiled. Replace. - 46 CFR 143.205(a) - 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 August 2025
Resolution: Verified engine air filters were replaced.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 14 July 2025
Resolved
Towing vessels must be equipped with the following equipment, as applicable to the area of operation. Illuminated magnetic compass or an illuminated swing-meter. The compass or swing-meter must be readable from each operating station. The vessel compass is not illuminated, replace.
46 CFR 140.725(d) - 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 August 2025
Resolution: verified operational capability of the magnetic compass light.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 July 2025
Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. Each towing vessel operating on oceans, coastwise, or Great Lakes routes must have a means to take blood pressure readings, splint broken bones, and apply large bandages for serious wounds. Vessel first aid kit was found to be incomplete and not compliant with regulations. Replace. - 46 CFR 140.435 - 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 August 2025
Resolution: verified additional equipment for Oceans/LBS route in First Aid Kit was onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 14 July 2025
Resolved
Each vessel must carry a certificate with a valid endorsement while subject to the Bridge-to-Bridge Act. Bridge to Bridge certificate was found expired. - 47 CFR 80.1005 - 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 August 2025
Resolution: Verified new Bridge to bridge certificate was onboard and uploaded in to certificates.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 14 July 2025
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford protection against hazards to life, property, and the enviroment. Aft flood light for working aft tow station was extinguished. replace. 46 CFR 140.205(a) 10c
Action required: 10 - Deficiency Rectified
Resolved 14 July 2025
Resolution: def rectified on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 11 April 2024
Resolved
Pressure vessels over 5 cubic feet in volume and over 15 pounds per square inch maximum allowable working pressure (MAWP) must be equipped with an indicating pressure gauge (in a readily visible location) and with one or more spring-loaded relief valves. The total relieving capacity of such relief valves must prevent pressure from exceeding the MAWP, as established by the manufacturer, by more than 10 percent. Provide pressure gauges that read above the 200 MAWP capacity of both air service tanks and control air service tanks.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2024
Resolved 23 April 2024
Resolution: Attending MI received photo evidence of the correction of deficiency
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 April 2024
Resolved
Electrical components that pose an electrical hazard must be in an enclosure. Remove dead end wire hanging over the port MDE.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2024
Resolved 23 April 2024
Resolution: Attending MI received photo evidence of the correction of deficiency
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 April 2024
Resolved
Decks and bulkheads designed to be watertight or weathertight must be maintained in that condition. Plug unused wire runs in the fwd storage compartment coming from the crash bulkhead space bellow.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2024
Resolved 23 April 2024
Resolution: Attending MI received photo evidence of the correction of deficiency
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 April 2024
Resolved
At least one lifebuoy must have a lifeline, secured around the body of the lifebuoy. Each lifeline on a lifebuoy must: Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. Replace Port lifebuoy lifeline.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2024
Resolved 23 April 2024
Resolution: Attending MI received photo evidence of the correction of deficiency
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 July 2022
Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail. C-drive compartment, Install Shaft guards on Port and STBD shaft sections on bulkhead against E-room. 46CFR144.820
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 October 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 July 2022
Resolved
All towing vessels must be operated in a manner that minimizes the risk of down-flooding and progressive flooding. Repair mechanism on chain locker hatch so it closes and opens freely. 46CFR140.610 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 October 2022
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 July 2022
Resolved
Shipboard lighting. Emergency lighting must be provided for all internal crew working and living areas. Repair Emergency lighting in the following locations, 3 in Engine room 01 galley, 01 mess deck, and 01 STBD steering station. 46CFR143.410 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 October 2022
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 1 July 2021
Resolved
The owner, managing operator, or master of a towing vessel must ensure that the vessel’s fire suppression equipment complies with applicable requirements and is in good working order. Fire Extinguisher bracket on STBD side main deck cannot be opened completely.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2021
Resolved 15 July 2021
Resolution: Fire extinguisher and bracket moved on the bulkhead so it can properly open.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 July 2021
Resolved
Machinery systems including main engines must be maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. A hose on the port side main diesel engine was not securely connected and leaking oil. Requires replacement or maintenance to stop leaking.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2021
Resolved 15 July 2021
Resolution: Hose on Port side MDE replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 July 2021
Resolved
Machinery systems including main engines must be maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. A valve on the STBD side main diesel engine was leaking oil. Requires replacement or maintenance to stop leaking
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2021
Resolved 15 July 2021
Resolution: Valve on STBD MDE replaced
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 July 2021
Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. A light fixture in the forward engineer locker was found hanging from the ceiling and not properly installed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2021
Resolved 15 July 2021
Resolution: Light fixture and wiring removed
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 July 2021
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. A light was missing next to the STBD oil tank aft of the hydraulics in the engine compartment. Requires a new light bulb or closed circuit.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2021
Resolved 15 July 2021
Resolution: Light fixture and wiring removed entirely
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 21 January 2021
Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight function properly. Main deck port and stbd entrance doors to superstructure are extremely difficult to open and close and require adjustment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2021
Resolved 15 March 2021
Resolution: Doors are in operable condition.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 21 January 2021
Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight function properly. Gasket is wasted on 2nd deck access hatch to engine room storage locker located directly forward of superstructure.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2021
Resolved 15 March 2021
Resolution: Gasket was replaced.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 21 January 2021
Resolved
Rails of equivalent protection must be installed near the periphery of the deck that provides strength and support equivalent to fixed rails. Forward stbd bulwark damaged and separated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2021
Resolved 15 March 2021
Resolution: Bulwark repaired with weld patch.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 21 January 2021
Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight function properly. Forepeak access hatch hinge is loose and
requires adjustment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2021
Resolved 15 March 2021
Resolution: Hinge was tightened.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 30 April 2020
Resolved
A vessel must carry appropriate day shapes. The vessel was found to be missing three balls and one diamond.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2020
Resolved 1 June 2020
Resolution: Vessel operator provided proof of purchase of dayshapes.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 April 2020
Resolved
At least two lifebuoys must be fitted with a floating electric light. One of the lights was found to be inoperable.
Action required: 10 - Deficiency Rectified
Resolved 30 April 2020
Resolution: Battery replaced. Rectified on site.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 April 2019
Resolved
Conduct an annual hydrostatic test on your bunkering line at 150% of the supply pump's maximum working pressure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2019
Resolved 16 May 2019
Resolution: Company provided a record of proper hydro test on bunker line.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 April 2019
Resolved
Every towing vessel of 26 ft or more while navigating is required to comply with the Bridge-to-Bridge Act and have a Bridge-to-Bridge Radio Telephony Certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2019
Resolved 15 April 2019
Resolution: Received a copy of the certificate. Cleared deficiency.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 April 2019
Resolved
Electrical equipment installed on the vessel must be maintained to ensure proper operation. During the inspection it was noted that the electrical switchboard ground light was not operational when tested.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2019
Resolved 16 May 2019
Resolution: Main electrical swithccboard's ground detection light was tested and working properly.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 11 April 2019
Resolved
The owner of a towing vessel must have procedures for the recovery of persons in the water to include the use of retrieval equipment. While performing a man overboard drill the crew did not have proper procedures to retrieve a person out of the water. A crew member was holding a ladder over the bulwark which he would not be able to hold while a person was climbing through it. Lastly, there was no way an unconscious person would be retrieved from the water.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2019
Resolved 30 May 2019
Resolution: Verified proper procedures for recovering persons on the water. All sat.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 16 August 2018
Resolved
Vsl is broadcasting invalid IMO #
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 April 2019
Resolution: Vessel is broadcasting proper IMO number.
Lifesaving
Issued 4 October 1994
Resolved
PROVIDE LIGHTS ON THE PFD's.
Condition: Unknown
Due 18 October 1994
Resolved 18 October 1994
Fire Fighting
Issued 4 October 1994
Resolved
PROVIDE PROPER SERVICING TO ALL PORTABLE B II'S
Condition: Unknown
Due 18 October 1994
Resolved 18 October 1994
Navigation
Issued 4 October 1994
Resolved
PROVIDE A SHIP'S BELL
Condition: Unknown
Due 18 October 1994
Resolved 18 October 1994
Unknown
Issued 4 October 1994
Resolved
PROVIDE A RANDOM DRUG TESTING PROGRAM.
Condition: Unknown
Due 1 November 1994
Resolved 10 November 1994
Lifesaving
Issued 4 October 1994
Resolved
PROVIDE A CATEGORY 1 406 MHz EPIRB
Condition: Unknown
Due 1 November 1994
Resolved 10 November 1994