MAURY USCG vessel records
← All vessels

JEAN PIERRE LAB

Built
2009
Last inspected
23 October 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 October 2025
…with no type recorded1
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9564308
WDE9670
992762
Flag
UNITED STATES
Maury page id
psix-992762

Documentation record

Registered dimensions (L × B × D)243.8 ft × 60.0 ft × 19.5 ft
Registered tonnagegross 2,287 / net 686
ITC dimensions (L × B × D)243.8 ft × 60.0 ft × 19.5 ft
ITC tonnagegross 2,287 / net 686
BuilderEASTERN SHIPBUILDING GROUP INC · PANAMA CITY, FL, UNITED STATES · built 2009
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 20 October 2025 · expires 30 November 2026
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2287 - Convention (Subpart B), Gross Ton
3639 - Dead Weight, Gross Ton
686 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 22 inspections, each with its date, unit and type; 14 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; 2 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MARGARET LAB Passenger (Inspected) · MISLE 934753 · 28 October 2020 · activity 7153181TRISTEN Towing Vessel · MISLE 994400 · 28 October 2020 · activity 7153181

Inspection history · 22

23 October 2025 Administrative Inspection · ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8260816
26 August 2025 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8217211
27 February 2025 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8085725
11 February 2025 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8078184
15 November 2024 ACP COI Oversight · COI Inspection · Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8034732
17 October 2024 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8020595
31 May 2024 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7924076
29 January 2024 Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7845070
22 March 2023 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7656307
20 January 2023 Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7624672
11 October 2022 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7575184
7 June 2022 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7471408
2 May 2022 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7442678
11 March 2022 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7410261
24 January 2022 ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7382711
14 January 2021 ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7124755
28 October 2020 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7153181
7 January 2020 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6883967
30 October 2019 Security Plan Review - ASP · Re-Inspection · Administrative Inspection · ACP COI Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6845303
20 December 2018 Administrative Inspection · ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6600648
19 September 2017 Annual Inspection · USCG Audit · Administrative Inspection · ACP Annual Oversight · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6270731
26 October 2016 ACP Annual Oversight
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6030270

Deficiency record · 14

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 30 October 2025 No resolution recorded
No OSV may carry flammable or combustible liquid cargoes in bulk without approval. The COI currently authorizes domestic carriage methyl alcohol. The vessel doesn’t have controlled vents (Pressure /Vacuum) on either the port or starboard methanol tanks, or onboard. Prior to the carriage of methanol. 46 CFR 125.110
Action required: 705 - Other - as specified
Due 30 October 2025 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 15 November 2024 Resolved
MARPOL VI 8.1 The bunker delivery note shall be accomplished by a rep sample of the fuel oil. Delivered taking into account guidelines developed by the org. The sample is to be sealed and signed by the suppliers rep, and the master or officer in charge of the operation on completion of bunkering ops. Returned under the ships control until the fuel oil is consumed but in any case for a period of not less than 12mo from the time of delivery. Ship to ship transfers no fuel samples have been retained.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2024
Resolved 10 December 2024
Resolution: Received report from ABS clearing the deficiency and taking corrective action via training.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 November 2024 Resolved
SOLAS 11.1 Reg 46 Every ship shall be provided with documentary evidence, to the satisfaction of the admin, of its fitness to operate with periodically unattended machinery spaces. Class cert. has ACC not ACCU for unattended machinery space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2024
Resolved 11 December 2024
Resolution: Vsl agrees with CG to go to Minimally manned machinery space aligning with ACC
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 29 January 2024 Resolved
Persons assigned duties as officer in charge of, or rating forming part of, a(n) navigational/engineering watch must receive 77 hours of rest in a 7-day period; STCW work rest logs did not accurately reflect the hours worked when compared to rough logs. To be checked at next topside inspection.
Action required: 705 - Other - as specified
Resolved 6 December 2024
Resolution: Received work rest logs and filled out for the month of november 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 24 January 2022 Resolved
Pressure-indicating gauges shall be such that the upper range of the gauge is not less than 1.2 times to 2 times the pressure at which the relieving device is set to function; the #1 Drybulk pump compressor air receiver, #2 Drybulk pump compressor air receiver, and 02 air receivers for the port Z-drive all had gauges not within 1.2 to 2 times the setting of the relieving device.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2022
Resolution: 835V was accepted by attending ABS Surveyor, see attached finding report.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 24 January 2022 Resolved
All required fire pump remote control locations must include the ability to accurately monitor fire pump pressure; fire pump pressure gauge on the bridge read 40 psi despite the pressure at the pump reading 90 psi.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2022
Resolution: 835V was accepted by ABS with an issued finding number, see attached report.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 14 January 2021 Resolved
Where penetrations of watertight bulkheads are necessary for access, arrantements are to be made to maintain the watertight integrity. All the watertight doors and hatches were loose and required to be tighten. 74 SOLAS (14) II-1/13-1.1
Action required: 10 - Deficiency Rectified
Due 14 January 2021
Resolved 14 January 2021
Resolution: Adjusted all watertight door and hatches to be secured.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 January 2021 Resolved
The crew shall have necessary knowledge and skills to handle fire emergency cases. Fire drill performed by the crew was inadequate. 74 SOLAS (14) II-2/15.1
Action required: 10 - Deficiency Rectified
Due 14 January 2021
Resolved 14 January 2021
Resolution: Required crew to perform three fire drills and educated the crew.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 October 2019 Resolved
For machinery spaces, the fixed piping system shall be such that 85% of the gas can be discharged into the space within 2 min. The flexible lines on the vessels CO2 system were only hand tightened, which would have casued leakage into the Co2 storage space.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2019
Resolved 18 November 2019
Resolution: ABS verified and cleared.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 30 October 2019 Resolved
Firefighter's outfit shall consist of protective clothing of material to protect the skin from the heat radiating from the fire and from burns and scalding by steam. The outer surface shall be water-resistant. Vessel did not have sufficient fire suit that fit crew member/ fire team member.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2019
Resolved 18 November 2019
Resolution: ABS verified and cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 October 2019 Resolved
All life-saving appliances shall: where exposed to sunlight, be resistant to deterioration. Vessel had at least three lifebuoys that displayed deterioration of the attached line.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2019
Resolved 18 November 2019
Resolution: ABS verified and cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 30 October 2019 Resolved
An immersion suit which has buoyancy and is designed to be worn without a lifejacket shall be fitted with a light complying with the requirements of paragraph 2.2.3 and the whistle prescribed by paragraph 2.2.1.14. The immersion suits aboard the vessel were missing lights.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2019
Resolved 18 November 2019
Resolution: ABS verified and cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangements rescue boats
Issued 30 October 2019 Resolved
An embarkation ladder complying with the requirements of paragraph 6.1.6 of the Code extending, in a single length, from the deck to the waterline in the lightest seagoing condition under all conditions of trim of up to 10 degrees and a list of up to 20 degrees either way shall be provided at each embarkation station or at every two adjacent embarkation stations for survival craft launched down the side of the ship. Vessels embarkation ladder had multiple shackles on ladder seized up from rust. Unable to attach to vessel.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2019
Resolved 18 November 2019
Resolution: ABS verified and cleared.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 30 October 2019 Resolved
The ignitability of combustible materials shall be restricted. The vessels fuel oil day tank (Port/Stbd) did not have sufficient flame screens on the vents.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2019
Resolved 18 November 2019
Resolution: ABS verified and cleared.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.