Records from 2009 to 2026. Most recent: inspection, 19 February 2026.
Documentation record
Registered dimensions (L × B × D)243.8 ft × 60.0 ft × 19.5 ft
Registered tonnagegross 2,287 / net 686
ITC dimensions (L × B × D)243.8 ft × 60.0 ft × 19.5 ft
ITC tonnagegross 2,287 / net 686
BuilderEASTERN SHIPBUILDING GROUP INC · PANAMA CITY, FL, UNITED STATES · built 2009
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 20 October 2025 · expires 30 November 2026
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it3639 - Dead Weight, Gross Ton
2287 - Convention (Subpart B), Gross Ton
686 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 32
19 February 2026
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8312919
6 January 2026
Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8290769
26 February 2025
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8085146
31 January 2025
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8073052
8 January 2025
COI Inspection · ACP COI Oversight · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8045282
21 August 2024
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7986481
11 March 2024
Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7877454
3 April 2023
Periodic Inspection · ACP Periodic Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7661581
9 April 2022
Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7427730
11 March 2022
In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7410241
11 March 2021
ACP Annual Oversight · Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7154105
10 January 2020
MTSA/ISPS Verification · Examination of Repairs · ACP COI Oversight · Administrative Inspection · Periodic Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6886992
1 October 2019
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6828305
26 February 2019
Annual Inspection · ACP Annual Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6632859
7 January 2019
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6606672
16 November 2018
Administrative Inspection
Administrative · Commandant (CG-ENG) · Activity 6582035
13 November 2018
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6580044
13 November 2018
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6583269
14 February 2018
ACP Annual Oversight · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6355316
2 January 2018
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6332557
21 December 2017
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6327481
15 November 2017
In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6307627
31 October 2017
In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6298629
24 September 2017
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6275258
23 January 2017
Annual Inspection · ACP Annual Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6075084
11 February 2016
Administrative Inspection · ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5813776
13 January 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5796529
21 August 2014
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4960528
22 February 2012
MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4246300
15 November 2010
ACP Annual Oversight
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3891795
9 January 2010
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3661366
18 February 2009
Plan Review (Other than "T")
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 3420546
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 19 February 2026
Resolved
Except as otherwise provided in this section, on a documented vessel, each unlicensed seafarer (seaman) must be: a citizen of the US, an alien lawfully admitted to the US for permanent residence; or a foreign national who is enrolled in the USMMA.
Marine Inspector was notified of 01 non-US resident employed on vessel.
60- Vessel must comply with 46 USC 8103 prior to movement.
Condition: Design Flaw
Action required: 60 - Rectify deficiencies prior to movement
Due 19 March 2026
Resolved 20 February 2026
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 14 January 2026
Resolved
No OSV may carry flammable or combustible liquid cargoes in bulk without approval. The COI currently authorizes domestic carriage methyl alcohol. The vessel doesn’t have controlled vents (Pressure /Vacuum) on either the port or starboard methanol tanks, or onboard. Both port and starboard pump room ventilation boxes are wasted, with the port having a temporary repair. Prior to the carriage of methanol.
46 CFR 125.110
Action required: 705 - Other - as specified
Due 14 January 2026
Resolved 22 January 2026
Resolution: ABS added finding/ recommendation that controlled vents and wasted P/S pump room vent boxes be repaired prior to carriage of methanol - with repair/modifications planned during scheduled dry dock.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 January 2026
Resolved
Exposed equipment which may become live, shall be earthed. Ground detection on switchboard the emergency switchboard indicates ground / has 03 extinguished bulbs while on e-gen load.
1974 SOLAS (Cons. 2009) II-1 /45.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2026
Resolved 22 January 2026
Resolution: ABS found that the faulty ground fault indicator bulbs of Emergency Switch Board were replaced satisfactorily.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 14 January 2026
Resolved
All ships of 500 gross tonnage and upwards shall have a gyro-compass bearing repeater, or other means to supply heading information visually at the emergency steering position. The gyro-compass repeater at the emergency steering position was inoperable.
1974 SOLAS (Cons. 2009) V /19.2.5.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2026
Resolved 22 January 2026
Resolution: ABS found taht faulty electrical wire connections of the emergency steering station gyro compass repeater were troubleshooted satisfactorily and the repeater was made operable to the satisfaction of the attending surveyor.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 March 2024
Resolved
Exposed equipment which may become live, must be earthed. Ground detection on switchboard indicates ground on phase C. Two lights on E-Gen switch board are extinguished.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 March 2024
Resolved 12 March 2024
Resolution: ABS report provided attesting that no ground was found. Lights replaced and ground detection no longer indicating ground.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 11 March 2024
Resolved
The oil record book shall be completed on each occasion of discharging overboard. ORB entries did not have quantities listed. MIs conducted training with crew.
Action required: 10 - Deficiency Rectified
Due 12 March 2024
Resolved 12 March 2024
Resolution: MIs conducted training with crew to ensure they understood the required entries for future use.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 17 January 2020
Resolved
Each launching appliance shall be so arranged that the fully equipped survival craft or rescue boat it serves can be safely launched. The rescue boat B weight exceeds the max load rating of the installed winch cable.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 January 2020
Resolved 23 January 2020
Resolution: ABS cleared
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 17 January 2020
Resolved
The liferaft painter system shall provide a connection between the ship and the liferaft and shall be so arranged as to ensure that the liferaft when released and, in the case of an inflatable liferaft, inflated is not dragged under by the sinking ship. Two liferafts had painters tied to the vessel, not properly tied to the hydrostatic release units.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 January 2020
Resolved 23 January 2020
Resolution: VESSEL REP PROPERLY INSTALLED THE PAINTER LINE TO THE HRU.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 January 2020
Resolved
All life-saving appliances shall: where exposed to sunlight, be resistant to deterioration. Vessel had one lifebuoy that displayed deterioration of the attached line.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 January 2020
Resolved 23 January 2020
Resolution: ABS cleared
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 17 January 2020
Resolved
An immersion suit which has buoyancy and is designed to be worn without a lifejacket shall be fitted with a light complying with the requirements of paragraph 2.2.3 and the whistle prescribed by paragraph 2.2.1.14. The immersion suits aboard the vessel were missing lights.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 January 2020
Resolved 23 January 2020
Resolution: ABS cleared
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 13 November 2018
Resolved
Complete satisfactory repairs to damaged areas of vessel hull and bulwarks.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2018
Resolved 3 December 2018
Resolution: Repairs inspected by attending RO surveyor.
Operations/Management › Cargo Transfer/Lightering › Persons in Charge Conference
Issued 15 November 2017
Resolved
Operation of a cargo or miscellaneous vessel not in compliance with the certificate of
inspection.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 November 2017
Resolved 26 February 2019
Resolution: Closed due to lack of evidenced of ongoing improper operations.
Operations/Management › Cargo Transfer/Lightering › Person in Charge Presence/Supervision
Issued 15 November 2017
Resolved
Operation of a cargo or miscellaneous vessel not in compliance with the certificate of
inspection. 46 CFR 97.50-1(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 November 2017
Resolved 26 February 2019
Resolution: Closed due to lack of evidence of ongoing improper operations.
Operations/Management › Cargo Transfer/Lightering › Person in Charge Presence/Supervision
Issued 31 October 2017
Resolved
Operation of a cargo or miscellaneous vessel not in compliance with the certificate of
inspection.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 23 December 2017
Resolution: See Activity #6327481.