Records from 2007 to 2026. Most recent: inspection, 3 June 2026.
Documentation record
Registered dimensions (L × B × D)200.0 ft × 35.0 ft × 12.5 ft
Registered tonnagegross 735 / net 735
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSOUTHWEST SHIPYARD · GALVESTON, TX, UNITED STATES · built 2007
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portBATON ROUGE, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 18 November 2025 · expires 31 December 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it735 - Simplified, Gross Ton
735 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 26
3 June 2026
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8390367
14 May 2025
Periodic Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8134944
26 May 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7919684
4 May 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7679509
21 March 2022
Administrative Inspection · Examination of Repairs · Deficiency Check · Internal Structural Exam · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7415552
11 May 2021
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7194239
21 April 2020
Administrative Inspection · MTSA Verification · Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6941906
15 January 2019
Examination of Repairs · Administrative Inspection · Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6612351
13 November 2018
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6583269
16 August 2018
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6533346
24 May 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6422113
1 March 2017
Drydock Exam · Internal Structural Exam · Examination of Repairs · Administrative Inspection · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6096258
10 March 2016
Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5833648
20 July 2015
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5187893
13 March 2014
Examination of Repairs · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4818841
27 June 2013
Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4633401
10 July 2012
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4375265
30 March 2012
COI Inspection · MTSA Verification · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4272933
14 April 2010
Examination of Repairs · Periodic Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3716493
17 April 2009
MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3454604
15 July 2008
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3268785
28 April 2008
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3194583
23 December 2007
Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3120241
2 August 2007
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3015665
19 April 2007
MTSA Verification · Initial Certification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2909220
1 March 2007
Construction Oversight · Internal Structural Exam · Cargo Tank Internal · Hull Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2879917
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 10 June 2026
Resolved
Each cargo tank of a tankship must be equipped with an intrinsically safe high-level alarm and a tank overfill alarm.
Marine Inspector identified overfill alarms on tanks 1 and 2 seized and not functioning.
Vessel shall enact permanent repairs to the satisfaction of the Coast Guard prior to loading cargo.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2026
Resolved 17 June 2026
Resolution: Due to inclement weather, received video of high level/overfill alarms for Cargo Tanks 1&2. Tested satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 21 March 2022
Resolved
Nonmetallic flexible hose must be in accordance with SAE J1942 (incorporated by reference: see 46 CFR 56.01-2) and may be installed only in vital and non-vital fresh and salt water systems, non-vital pneumatic systems, lube oil and fuel systems, and fluid power systems.
During inspection MI witnessed installed prime mover fuel oil hoses without the SAE J1942 designation. Provide documentation that the installed fuel oil hoses meet SAE J1942 or Replace all prime mover Fuel oil hoses to meet the SAE J1942 standard to the satisfaction of a Coast Guard Marine Inspector, prior to the use of the installed prime mover. 46CFR32.35-1, 46CFR56.60-25(8)(b)(1); 705c
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 1 April 2022
Resolution: Documentation and photos excepted attesting to replacement of fuel hoses meeting the SAE J1942 standard.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 18 January 2019
Resolved
Vessel's Certificate of Documentation has expired. Vessel route is reduced to Rivers. Vessel may not transit any portion of the GIWW that is not deemed a river, lake, or canal.
Action required: 705 - Other - as specified
Resolved 22 January 2019
Resolution: Cleared IAW D8 Policy issued 27 Aug 1998. Vessel not required COD for route intended.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 13 March 2014
Resolved
Remove excessive buildup of polymer within the vapor header/drops.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2014
Resolution: Shipyard cleaned entire vapor system.
Construction/Loadline › Hull › Hull Plating
Issued 14 April 2010
Resolved
damaged deck gunnel port and stbd side
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 14 April 2010
Resolution: deck gunnel inserts on port and stbd side