Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
5902 - Convention (Subpart B), Gross Ton
13663 - Displacement, Gross Ton
5542 - Regulatory (Subpart C or D), Gross Ton
3857 - Convention (Subpart B), Net Ton
5542 - Regulatory (Subpart C or D), Net Ton
11566 - Dead Weight, Ton
Maury page id
psix-994266
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. Only barges and towing
vessels are in this archive, so any other vessel type in the same activity does not
appear here: these lists are a floor, not a complete manifest.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 17 May 2022Resolved
Each non-self propelled ship must have a fixed or portable shower and eyewash fountain that operates during cargo transfer. The eyewash fountain was not operating efficiently and the shower would not work.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 May 2022
Resolution: Unit recieved video showing deficiency has been corrected.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 2 March 2021Resolved
Each non-self-propelled ship must have a fixed or portable shower and eyewash station that operates during cargo operations in any ambient temperature located on the weather deck.
MI was not able to verify operation of shower and eyewash station. Provide evidence of operation prior to carriage of cargoes requiring shower and eyewash.
Action required: 705 - Other - as specified
Due 2 March 2021
Resolved 12 April 2021
Resolution: Recieved video of operable eywash station
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 March 2021Resolved
The frame or support of each semi portable fire extinguisher must be welded or otherwise permanently attached to a bulkhead or deck.
Semi-portable fire extinguisher on board was affixed with a non-permanent ratchet strap.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2021
Resolved 15 April 2021
Resolution: Witnessed picture of permanent mounting construction.
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 24 March 2014Resolved
Prove proper operation of anchor
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2014
Operations/Management › Pollution › General
Issued 11 May 2012Resolved
Provide last 3 sulfur content results from bunkering. Vessel does not log sulfur content.
Action required: 705 - Other - as specified
Due 23 May 2012
Resolved 3 August 2012
Resolution: Proof provided rectification.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 11 May 2012Resolved
Calibration of portable gas meters were not logged. Provide log dedicated for calibration of portable gas meters.
Action required: 705 - Other - as specified
Due 23 May 2012
Resolved 3 August 2012
Resolution: Proof provided rectification.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 May 2012Resolved
Prove proper operation of the eye wash station. Station was not functional.
Action required: 705 - Other - as specified
Due 23 May 2012
Resolved 3 August 2012
Resolution: Proof provided rectification.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 March 2010Resolved
Repair eye wash and shower station required by 46 CFR 153.216 to provide an effective flow of water to wash eyes. Complete prior to loading chemical cargo under 153 or IBC code.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 April 2010
Resolved 30 March 2010
Resolution: Eye wash station was inspected and corrected to the satifaction of attending MI.
Documentation › Logs/Records › Cargo Record Book (NLS)
Issued 26 March 2010Resolved
Provide Cargo Record Book in accordance with Annex II. Complete prior to loading chemical cargo under 153 or IBC code.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 April 2010
Resolved 30 March 2010
Resolution: Cargo Record Book was provided onboard the vessel.