Records from 2011 to 2026. Most recent: inspection, 13 May 2026.
Documentation record
Registered dimensions (L × B × D)73.0 ft × 32.0 ft × 7.1 ft
Registered tonnagegross 166 / net 112
ITC dimensions (L × B × D)73.0 ft × 32.0 ft × 7.1 ft
ITC tonnageNot recorded
BuilderDIVERSIFIED MARINE INC · PORTLAND, OR, UNITED STATES · built 2009
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNENANA, AK
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 30 January 2026 · expires 31 January 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it166 - Regulatory (Subpart C or D), Gross Ton
112 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 16
13 May 2026
Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8376919
2 March 2026
Examination of Repairs · Vessel Attendance
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8310463
23 April 2025
COI Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8118166
14 May 2024
Administrative Inspection · COI Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7908786
25 April 2019
COI Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6668781
7 March 2018
Spot Check · MTSA Verification
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6367907
14 May 2017
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6167706
11 June 2015
Industry Initiated Exam · MTSA Verification
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5155453
3 June 2015
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5145176
2 June 2015
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5145275
29 May 2014
Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 4914201
29 May 2014
Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 4914231
19 July 2012
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4385212
11 July 2012
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4378021
8 May 2012
Administration
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4780286
22 November 2011
Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 4254010
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 April 2025
Resolved
Combustible products onboard a towing vessel must be stored in a desingated storage room when not in use. Inspector observed boxes in the engine compartment, that were not in a designated storage room. 46CFR142.225
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 4 June 2025
Resolved 7 May 2025
Resolution: Boxes were removed from engine room.
10 - Safety of Navigation › N/A - No Subsystem › Bridge Navigation Watch Alarm System (BNWAS)
Issued 23 April 2025
Resolved
The time interval for the pilothouse alerter system must be adjustable. The time may be adjusted by the owner or managing
operator but must not be in excess of 10 minutes. Inspector observed BNWAS was adjusted to 12 minutes. 46CFR143.450(b)
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 4 June 2025
Resolved 7 May 2025
Resolution: BNWAS was adjusted to 10 minutes
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 23 April 2025
Resolved
MSD must be secured in Non discharge Zones by removing handle, padlocking, wire tie or locking the space. Inspector observed MSD overboard discharge valve was not secured. 33CFR159.7
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 4 June 2025
Resolved 4 June 2025
Resolution: Zip tie was installed to permanently secure the overboard discharge
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 23 April 2025
Resolved
Each space shall have two means of escape that are maintained and operated as intented. Inspector found emergency escape hatch in engine room was impeded by equipment. 46CFR137.215
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 4 June 2025
Resolved 7 May 2025
Resolution: Equipment was removed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 May 2024
Resolved
Each towing vessel must carry at least one appropriately-sized life jacket, approved under approval series 160.002, 160.005, 160.055, 160.155, or 160.176, for each person on board. The vessel is certificated for a total of 12 persons, only 10 life jackets were on board. Place 02 additional life jackets on board with vessel's name, approved light and whistle prior to carrying more than 10 persons on board.
46 CFR 141.340(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 28 May 2024
Resolution: Additional lifejackets placed onboard and marked with vessel name.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 14 May 2024
Resolved
Each towing vessel operating in those regions must carry at least one appropriate-size immersion suit, approved under approval series 160.171, for each person on board. The vessel is certificated for a total of 12 persons, only 10 immersion suites were on board. Place 02 additional immersion suites on board prior to carrying more than 10 persons on board.
46 CFR 141.350(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 28 May 2024
Resolution: 02 additional immersion suits were marked with vessel name and placed onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 May 2024
Resolved
A 40-B portable fire extinguisher must be located near the storage room or cabinet. This is in addition to the portable fire extinguishers required by tables 142.230(a) and 142.230(b) of this part. No portable fire extinguisher was installed near flammable material cabinet, install additional portable fire extinguisher.
46 CFR 142.225(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 28 May 2024
Resolution: Portable fire extiguisher was mounted onboard in a bracket.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 May 2024
Resolved
Each towing vessel operating in oceans and coastwise service must have a line throwing appliance approved under approval series 160.040. The vessel is only equipped with a shoulder fired line throwing appliance with type approval under 46 CFR 160.031. Equip vessel with line throwing appliance approved under approval series 160.040 or submit request for "special consideration".
46 CFR 141.385
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 23 May 2024
Resolution: OCMI approved request for special consideration to use shoulder fired line throwing appliance in lieu of line throwing appliance under approval series 160.040.