Records from 2009 to 2026. Most recent: inspection, 19 March 2026.
Documentation record
Registered dimensions (L × B × D)140.0 ft × 40.0 ft × 9.0 ft
Registered tonnagegross 423 / net 423
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSNEED SHIPBUILDING INC. · CHANNELVIEW, TX, UNITED STATES · built 2009
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portMORGAN CITY, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 December 2025 · expires 31 January 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it423 - Simplified, Gross Ton
423 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 23
19 March 2026
Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8328886
3 April 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8104712
12 March 2025
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8093137
29 May 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7922796
4 January 2024
Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7843090
25 April 2023
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7675634
10 February 2022
Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7393948
5 March 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7150762
23 April 2020
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6942845
24 March 2020
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6930916
9 January 2019
Internal Structural Exam · Examination of Repairs · Administrative Inspection · COI Inspection · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6607857
6 April 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6386379
6 January 2017
Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6066947
17 March 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5835498
22 January 2015
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5057288
28 March 2014
COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4824332
13 February 2014
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4799368
21 November 2013
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4757154
7 March 2012
Internal Structural Exam · Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4258330
21 July 2011
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4089459
20 July 2011
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4088168
28 May 2010
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3749963
11 May 2009
COI Inspection · Cargo Tank Internal · Drydock Exam · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3472343
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 24 March 2020
Resolved
Draft marks must be painted in a contrasting color to the hull.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2020
Resolved 22 April 2020
Resolution: Vessel Rep supplied photos showing the draft marks painted a contrasting color. Draft marks SAT.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 April 2018
Resolved
The vessel is in a "laid Up" ABS status and has dropped their loadline and class certificate. The vessels COI route has to be adjusted to reflect that.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 6 April 2018
Resolved 6 April 2018
Resolution: Coast Guard discussed with vessel representatives and will amend the COI to reflect LBS route. The barge plans to operate inland waters only
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 28 March 2014
Resolved
Transfer procedures not available for inspection. Corrected on the spot.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2014
Construction/Loadline › Hull › Stiffener
Issued 13 February 2014
Resolved
Need to correct pick-up welds in the port rake on verticle channels on aft bulkhead
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2014
Construction/Loadline › Hull › Bracket
Issued 13 February 2014
Resolved
minor crack in weld in top corner trip bracket in starboard stern void.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2014
Construction/Loadline › Hull › Bracket
Issued 13 February 2014
Resolved
Need to replace one trip bracket in port stern void
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2014
Resolved 28 February 2014
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 13 February 2014
Resolved
draft marks need to be painted contrasting color to the hull.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2014
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 21 July 2011
Resolved
paint on vsls name, homeport and draft markings was worn due to operations. Vessel rep was instructed to repaint with contrasting color.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2011
Resolution: Paint was renewed.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 21 July 2011
Resolved
Vsl's rep did not have transfer procedures available for Coast Guard inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2011
Resolution: Transfer procedures were placed onboard vsl.
Electrical › Electric Supply System (service) › Battery Installation
Issued 21 July 2011
Resolved
Battery Box was missing. Vsl's rep was instructed to replace the missing battery box.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2011
Resolution: Battery box was installed and secured.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 21 July 2011
Resolved
Lagging on Cargo pump diesel engine was loose and missing wire to secure it to the exhaust pipe
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2011
Resolution: Lagging was secured.
Deck/Cargo › Holds/Tanks › Hatch
Issued 21 July 2011
Resolved
Cargo and void hatches not marked "DANGER KEEP OUT"
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2011
Resolution: Stenciling completed.