Records from 2016 to 2026. Most recent: inspection, 27 March 2026.
Inspection history · 30
27 March 2026
Administrative Inspection · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8331875
10 December 2025
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8273879
25 June 2025
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8168276
22 January 2025
COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8066728
18 November 2024
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8033413
5 January 2024
Damage Survey · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7845739
21 December 2023
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7845772
24 October 2023
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7813580
25 July 2023
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7751632
18 May 2023
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7689040
22 March 2023
Administrative Inspection · Periodic Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7659216
7 March 2023
Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7644648
21 November 2022
Drydock Exam · Examination of Repairs · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7592623
22 August 2022
Administrative Inspection · Excursion Permit
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7540382
6 April 2022
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7412712
23 February 2021
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7144664
5 August 2020
Construction Oversight
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7025706
23 January 2020
COI Inspection · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6893769
30 December 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6878548
29 October 2019
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6844280
2 May 2019
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6674035
24 January 2019
In-Service Inspection · Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6610099
10 September 2018
Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6536836
23 July 2018
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6488053
4 April 2018
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6384765
27 November 2017
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6313469
25 April 2017
Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6132530
15 March 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6105346
18 October 2016
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6024528
31 March 2016
Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5846884
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 January 2025
Resolved
At each inspection for certification, periodic inspection and at other times necessary, the inspector will determine that all fire-extinguishing equipment is in suitable condition and may require any tests necessary to determine the condition of the equipment Vessel's fire pump shaft seal was leaking.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2025
Resolved 7 April 2025
Resolution: Vessel installed new fire hose.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 January 2025
Resolved
All vessels except barges shall carry at least the minimum number of fire axes as set forth in Table 95.60-5(a). Vessel had 01 fire axe.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2025
Resolved 28 February 2025
Resolution: 01 Fire axe was purchased and is onboard for a total of 02 required fire axes.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 22 January 2025
Resolved
For each shore power connection each switchboard must have: An indicator connected to the shore side of the circuit breaker or fused switch. Switchboards shore power available indicator light was extinguished.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2025
Resolved 20 February 2025
Resolution: Received objective evidence of a photograph showing the shore power availabliltiy bulb is aluminated.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 November 2024
Resolved
Each vessel must meet the applicable requirements for subdivision and stability in 46 CFR subchapter S. Provide updated stability letter/book addressing weight changes/crane lift calculations for the existing A frame crane within 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 December 2024
Resolved 27 March 2026
Resolution: ABS issued updated Stability Letter on 05FEB2026.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 November 2024
Resolved
Cranes must comply with 46 CFR 107.258, 107.260, 108.601, 109.437, 109.439, 109.521, 109.525, and 109.527. Submit required plans and information as per 46 CFR 107.309 to the USCG Marine Safety Center and obtain plan approval for the existing A frame crane within 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 December 2024
Resolved 25 June 2025
Resolution: Vessel received plan approval for crane
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 November 2024
Resolved
Cranes must comply with 46 CFR 107.258, 107.260, 108.601, 109.437, 109.439, 109.521, 109.525, and 109.527. Conduct weight testing IAW 46 CFR 107.258 on the existing A frame crane to the satisfaction of the attending USCG Marine Inspector prior to using the crane.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 December 2024
Resolved 25 June 2025
Resolution: Conducted satisfactory rated load test
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 November 2024
Resolved
Each applicant for approval of plans and for an original Certificate of Inspection shall submit piping diagrams
of Fluid-driven power and control systems. Provide USCG Marine Safety Center approved hydraulic piping system plans within 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 December 2024
Resolved 25 June 2025
Resolution: Vessel received approval for the power fluid system
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 November 2024
Resolved
Valves must be designed for the maximum pressure to which they may be subjected, but in no case must the design pressure be less than 50 psig. #1 fuel fill port leaking under residual pipe pressure. Valve to be removed and both flanges secured with gaskets, blanks, and bolts as needed to provide leak free operational test until replacement valve is installed and tested.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 November 2024
Resolution: Repairs made and tested to the satisfaction of the attending CGMI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 5 January 2024
Resolved
The main steering gear must be capable of steering the vessel at maximum ahead service speed, which must be demonstrated to the satisfaction of the cognizant Officer in Charge, Marine Inspection. While underway the vessel lost steering due to a loose wire.
Action required: 10 - Deficiency Rectified
Resolved 5 January 2024
Resolution: Wire was retightened and successful sea trials were conducted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 March 2023
Resolved
The spring in a relief valve in service for pressures up to and including 250 pounds per square inch shall not be reset for any pressure more than 10 percent above or 10 percent below that for which the relief valve is marked. When tested, the relieve valves did not reset once tripped.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2023
Resolution: Verified new relief valves were installed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 March 2023
Resolved
No repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall be made without the knowledge of the Officer in Charge, Marine Inspection. Fire main has soft patch in engine room piping. make permanent repairs and hydrostatically test in presence of Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 May 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 7 March 2023
Resolved
An inspection either general or partial depending on the circumstances shall be made whenever any important repairs or alterations are undertaken. Vessel's bow thruster was removed for repair, the through hull penetration will be temporarily repaired by blanking it off, by gasket /bolted flange plate.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 April 2023
Resolved 18 May 2023
Resolution: BOW THRUSTER INSTALLED.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 January 2019
Resolved
Vessel draft marks should be of contrasting color to the hull. Draft marks are same color as hull, paint with color contrasting to hull.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 February 2019
Resolution: Painted draft marks in contrasting color to hull.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 10 September 2018
Resolved
Vsl is broadcasting invalid IMO # and incorrect Name
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 17 October 2018
Resolution: Received an e-mail from vessel representative that the vessel was broadcasting the proper AIS information. Checked VIVS and no errors existed.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 4 April 2018
Resolved
The position of the rudder must be shown at the primary operation station. The rudder angle indicator at the operating station does not accurately reflect the rudder position when moving to stbd. Prove proper operation of rudder angle indicator.
Action required: 705 - Other - as specified
Due 11 April 2018
Resolved 11 April 2018
Electrical › Electric Generation Source (service) › Panelboard
Issued 4 April 2018
Resolved
TJT01 Replace in operating hertz meter for #1 SSDG by 11APR18. 46CFR111.30-25
Action required: 10 - Deficiency Rectified
Due 11 April 2018
Resolved 11 April 2018
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 April 2018
Resolved
TJT02 Install proper hard wired outlet for on deck LED lighting (extension cord being used) by 11APR18 46CFR111-81.01
Action required: 10 - Deficiency Rectified
Due 11 April 2018
Resolved 11 April 2018
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 April 2018
Resolved
TJT03 Install mechanical wire hangers for all wire bundles in engine room (various locations) by 11APR18 46CFR111-1.1
Action required: 10 - Deficiency Rectified
Due 11 April 2018
Resolved 11 April 2018
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 4 April 2018
Resolved
TJT04 Install lagging on elbow of exhaust after turbo on thruster engine by 11APR18 46CFR56-50.1
Action required: 10 - Deficiency Rectified
Due 11 April 2018
Resolved 11 April 2018
Engineering › Lubricating Oil Storage/Transfer System › Hose
Issued 4 April 2018
Resolved
TJT05 Install proper schedule 80 piping for case drain hydraulic in the engine room from on deck crane by 1APR18. 46CFR56-60.25
Action required: 10 - Deficiency Rectified
Due 11 April 2018
Resolved 11 April 2018
Engineering › Pressure Vessel › Relief Valve
Issued 4 April 2018
Resolved
TJT06 Replace relive valve for #2 air receiver by 11APR18. 46CFR54-15.10
Action required: 10 - Deficiency Rectified
Due 11 April 2018
Resolved 11 April 2018
Engineering › Pressure Vessel › Relief Valve
Issued 4 April 2018
Resolved
TJT07 Do not operate #1 air compressor and air receiver, replace air receiver relief valve. 46CFR54-15.10
Action required: 10 - Deficiency Rectified
Due 11 April 2018
Resolved 11 April 2018
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 25 April 2017
Resolved
Provide Annual Bridge to Bridge Certificate
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 10 May 2017
Resolution: new license issued dated 08MAY17
Lifesaving › Inflatable Liferafts › Capacity
Issued 15 March 2017
Resolved
SE01 Vessel authorized to temporarily install a 20 person liferaft on one side and a 25 person liferaft on the other side of the vessel while the vessel's required liferafts are being serviced.
Action required: 705 - Other - as specified
Due 30 March 2017
Resolved 29 March 2017
Engineering › Steering Gear System › Bracket/Clamp
Issued 31 March 2016
Resolved
Bushings on STBD rudder had excessive movement. Renew or replace bushings.
Condition: Improper/Lack of Maintenance
Due 30 April 2016
Resolved 26 April 2016
Resolution: New bushings installed on both rudders.
Lifesaving › Line-Throwing Appliances › Lines
Issued 31 March 2016
Resolved
Line throwing appliance is not equipped with 500' aux line iaw 46CFR133.170
Condition: Invalid
Due 30 April 2016
Resolved 26 April 2016
Resolution: 1500 Aux line provided.
Electrical › Electric Generation Source (service) › Panelboard
Issued 31 March 2016
Resolved
Provide cover for light on switch board labled Gen #2 heater.
Condition: Damaged By Earlier Event
Due 30 April 2016
Resolved 26 April 2016
Resolution: New covers installed.
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 31 March 2016
Resolved
Provide fuel oil transfer diagram at transfer location.
Condition: Invalid
Due 30 April 2016
Resolved 26 April 2016
Resolution: New transfer procedures made and posted.
Operations/Management › Vessel Activity › Other
Issued 31 March 2016
Resolved
Complete commercial dive audit.
Condition: Improper/Lack of Maintenance
Due 30 April 2016
Resolved 26 April 2016
Resolution: Dive audit sucessfully completed.
Engineering › Fuel Oil Service System › Valve
Issued 31 March 2016
Resolved
Emergency fuel shut off was found broken.
Condition: Improper/Lack of Maintenance
Due 31 March 2016
Resolved 31 March 2016
Resolution: Valve repaired. Corrected on the spot.