MAURY USCG vessel records
← All vessels

HTCO 3066

HTCO 3066 is a 2009 tank barge. The Coast Guard has recorded 15 inspections since 2009, most recently in September 2024, along with 10 deficiencies and 1 casualty investigation in 2020.

Records from 2009 to 2024. Most recent: inspection, 6 September 2024.

Built
2009
Last inspected
6 September 2024
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 6 September 2024
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 12 calendar years (2009–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

998376
Flag
UNITED STATES
Maury page id
psix-998376

Documentation record

Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS INC · MADISONVILLE, LA, UNITED STATES · built 2009
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portHOUSTON, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 28 May 2026 · expires 30 June 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

HOCKLEY Towing Vessel · MISLE 565791 · 2 March 2020 · activity 6920792HTCO 3067 Tank Barge · MISLE 998377 · 2 March 2020 · activity 6920792

Inspection history · 15

6 September 2024 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7994889
12 August 2024 Drydock Exam · Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7979892
2 March 2020 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6920792
12 August 2019 COI Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6776096
31 May 2018 MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6430300
14 August 2017 Administrative Inspection · Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6241887
26 May 2016 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5886741
29 May 2015 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5141219
29 March 2015 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5095637
5 June 2014 Drydock Exam · COI Inspection · Internal Structural Exam · MTSA Verification · Cargo Tank Internal
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4879547
12 September 2012 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4439392
30 July 2012 MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4410733
10 August 2011 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4112575
16 June 2010 Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3768218
26 March 2009 Internal Structural Exam · Initial Certification · Cargo Tank Internal · MTSA Verification · Hull Examination · Construction Oversight · Deadweight Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3462942

Deficiency record · 10

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 September 2024 Resolved
Nonmetalic flexible hose may be used in lube oil, fuel oil, and fluid power systems only where flexibility is required and lengths not exceeding 30 inches. Vessel had several hoses used for fuel and/or lube oil which exceeded 30 inches.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 October 2024
Resolved 10 September 2024
Resolution: Vessel installed hard points and sections of metallic pipe between 30" nonmetallic flexible hoses. Accepted photos and videos as evidence of completion due to imminent hurricane.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 6 September 2024 Resolved
Every tank vessel subject to the regulations in this subchapter shall be inspected every 5 years or more often, if necessary, by the Coast Guard to see that the hull of the vessel complies with marine inspection laws, and the regulations in this subchapter, and when applicable, subchapters E, F, J, O, Q, S, and W of this chapter and 33 CFR parts 155 and 157. Vessel had two holes on the starboard side of the stern’s shell plating which impacted the watertight integrity of the vessel.
Action required: 60 - Rectify deficiencies prior to movement
Due 13 September 2024
Resolved 9 September 2024
Resolution: Vessel repaired damage by cropping and renewing area, witnessed pneumatic NDT, all satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 6 September 2024 Resolved
All exposed and dangerous places such as gears and machinery shall be properly protected with covers, guards or rails in order that the danger of accidents may be minimized. Vessel had exposed rotating machinery in the area containing the thermal fluid heater and switchboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2024
Resolved 9 September 2024
Resolution: Installed a guard to prevent anyone from accidentally coming in contact with the hazard.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 September 2024 Resolved
In general, connections and terminations to all conductors must retain the original electrical, mechanical, flame-retarding, and, where necessary, fire-resisting properties of the cable. Vessel had an improper termination of a wire running to the bow along centerline of the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2024
Resolved 9 September 2024
Resolution: Vessel had removed the cable in question.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 6 September 2024 Resolved
All exposed and dangerous places such as gears and machinery shall be properly protected with covers, guards or rails in order that the danger of accidents may be minimized. Vessel had not installed thermal protection coverings (lagging) around hot surfaces and/or pipelines.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2024
Resolved 9 September 2024
Resolution: Vessel had installed proper lagging in all required areas.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 September 2024 Resolved
The tank overfill alarm required by paragraph (a) of this section must activate a visible and audible alarm so that it can be seen and heard on the vessel where cargo transfer is controlled and in the cargo deck area. Vessel had a broken mounting for the overfill alarm light.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 October 2024
Resolved 9 September 2024
Resolution: Vessel had replaced the damaged light and assembly in kind with a new light assembly.
02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 6 September 2024 Resolved
The last 1.0 meter (3.3 feet) of vapor piping upstream of the vessel vapor connection and each end of a vapor hose must be painted in the sequence of red/yellow/red. The width of the red bands must be 0.1 meter (0.33 foot) and the width of the middle yellow band must be 0.8 meter (2.64 feet); and labeled with the word “VAPOR” painted in black letters at least 50.8 millimeters (2 inches) high. Vessel did not have the work “VAPOR” stenciled on the piping.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 October 2024
Resolved 9 September 2024
Resolution: Proper stenciling, labeled with the word “VAPOR” painted in black letters at least 50.8 millimeters (2 inches) high, had been added.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 6 September 2024 Resolved
Based on the employer's evaluation of the environmental monitoring, whenever the airborne concentration of benzene within an area exceeds or reasonably can be expected to exceed the permissible exposure limits, the person in charge shall mark the area as a regulated area. Vessel had not completed painting the benzene markings for the regulated area.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2024
Resolved 9 September 2024
Resolution: Vessel had completed painting the white benzene line around the exterior of the deck.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 September 2024 Resolved
Batteries must be constructed to take into account the environmental conditions of a marine installation, including temperature, vibration, and shock and is protected from falling objects. Vessel had a battery in a battery box which did not have a lid, therefore not protected from falling objects and presenting a shock risk.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2024
Resolved 9 September 2024
Resolution: Vessel had added a proper cover for the battery box.
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 30 July 2012 Resolved
Provide approved test procedures for TFH
Action required: 705 - Other - as specified
Due 31 August 2012
Resolved 12 September 2012
Resolution: Approved test procedures and owners manual are both on board.

Casualty record · 1

2 March 2020Routine · role: Involved in a Marine Casualty · activity 6920792
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.