Records from 2009 to 2021. Most recent: inspection, 14 September 2021.
Inspection history · 15
14 September 2021
PSC B · COC-TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7308249
18 June 2021
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7228958
20 November 2020
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7099011
20 November 2020
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7115213
1 August 2020
Deficiency Check · COC-TVE Renew · PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7021565
29 January 2019
COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6615814
13 July 2017
COE-Administrative
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6211825
9 June 2017
COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6169388
16 May 2017
COE-Dockside · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6142090
11 April 2017
COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6121841
3 October 2016
COE-Dockside
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6014774
2 October 2016
Administrative Inspection · COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6006749
5 July 2016
Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5918699
23 September 2015
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5726824
9 May 2009
COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3468515
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 20 November 2020
Resolved
Due to a surge event while conducting cargo discharging operations, damage was reported to the #2 and #3 starboard cargo manifold and associated piping. Prior to using these manifolds in the US, provide report from Class attesting to the proper survey, repair and testing as necessary to these manifolds and any subsequently identified damage resulting from this incident
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 December 2020
Resolution: Verified class survey to the satisfaction of the Coast Guard
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 14 August 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Due to a defective CPU module (Q01) ship is unable to start ballast/stripping pumps remotely or locally.
74 SOLAS (04) I/11(A)
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 31 August 2020
Resolved 28 August 2020
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 14 August 2020
Resolved
The means to stop the flow must be operable from the cargo deck, cargo control room, or the usual operation station of the person in charge of the transfer operation. Emergency shut down devices from the deck and cargo control room are inoperable due to a defective CPU module (Q01).
33 CFR 155.780(c)
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 31 August 2020
Resolved 28 August 2020
Engineering › Steam System (auxiliary) › Piping
Issued 11 April 2017
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Steam isolation valve on deck and steam manifold over the NR6 port cargo tank are leaking approx 5L of water per hour. 50AC
Condition: Improper/Lack of Maintenance
Due 11 May 2017
Resolved 17 May 2017
Resolution: CLASS REPORT RCVD. LEAKING STEAM ISOLATION VALVE PACKING AND FLANGE GASKETS WERE RENEWED. LEAKING SECTION OF MANIFOLD PIPING WAS CROPPED AND RENEWED. STEAM LEAKAGE STOPPED.