BW ORINOCO is a 2007 tank ship. The Coast Guard has recorded 13 inspections since 2016, most recently in September 2021, along with 4 deficiencies and 2 operational controls.
Records from 2016 to 2021. Most recent: inspection, 14 September 2021.
This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it74998 - Dead Weight, Metric Ton 89786 - Displacement, Metric Ton 43797 - Convention (Subpart B), Gross Ton 21967 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 20 November 2020Resolved
Due to a surge event while conducting cargo discharging operations, damage was reported to the #2 and #3 starboard cargo manifold and associated piping. Prior to using these manifolds in the US, provide report from Class attesting to the proper survey, repair and testing as necessary to these manifolds and any subsequently identified damage resulting from this incident
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 December 2020
Resolution: Verified class survey to the satisfaction of the Coast Guard
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 14 August 2020Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Due to a defective CPU module (Q01) ship is unable to start ballast/stripping pumps remotely or locally.
74 SOLAS (04) I/11(A)
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 31 August 2020
Resolved 28 August 2020
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 14 August 2020Resolved
The means to stop the flow must be operable from the cargo deck, cargo control room, or the usual operation station of the person in charge of the transfer operation. Emergency shut down devices from the deck and cargo control room are inoperable due to a defective CPU module (Q01).
33 CFR 155.780(c)
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 31 August 2020
Resolved 28 August 2020
Engineering › Steam System (auxiliary) › Piping
Issued 11 April 2017Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Steam isolation valve on deck and steam manifold over the NR6 port cargo tank are leaking approx 5L of water per hour. 50AC
Condition: Improper/Lack of Maintenance
Due 11 May 2017
Resolved 17 May 2017
Resolution: CLASS REPORT RCVD. LEAKING STEAM ISOLATION VALVE PACKING AND FLANGE GASKETS WERE RENEWED. LEAKING SECTION OF MANIFOLD PIPING WAS CROPPED AND RENEWED. STEAM LEAKAGE STOPPED.