Inspection history · 19
22 July 2026
Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8442444
30 July 2025
Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8198118
15 July 2024
Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7958643
12 June 2023
Internal Structural Exam · COI Inspection · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7704249
26 July 2022
Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7516084
7 September 2021
Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7306396
10 November 2020
Periodic Inspection · Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7093054
14 November 2019
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6855682
8 October 2019
Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6827521
24 May 2018
COI Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6431262
26 March 2014
Deficiency Check · Industry Initiated Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 4823493
26 August 2013
Industry Initiated Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 4697286
19 December 2012
DAPI Audit
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 4505081
26 November 2012
Type not recorded
No type recorded · Station Marblehead · USCG Great Lakes District (CGD-GL) · Activity 4491646
29 August 2012
Administration
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 4425091
5 December 2008
Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3374803
26 July 1996
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 50261
13 June 1995
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 154999
15 October 1993
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 188846
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 12 June 2023
Resolved
Life Floats shall be stenciled with the vessel's name in a contrasting color to the hull, in 4" block letters. Apply appropriate markings to the life float within 14 days.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 August 2023
Resolved 30 August 2023
Resolution: The life float is labeled and the deficiency is cleared.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 June 2023
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquids. The Starboard generator has a fuel leak at the fuel filter which must be repaired prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 August 2023
Resolved 1 September 2023
Resolution: Fittings were replaced and no leaks are present. The deficiency is cleared.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 12 June 2023
Resolved
Piping and machinery components that exceed 428* F, must be insulated. Install appropriate insulation onto turobo charger outlet piping prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 August 2023
Resolved 1 September 2023
Resolution: Appropriate insulation is satisfactorily installed on exposed components. The deficiency is cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 September 2021
Resolved
The bowls on the fuel filters are made of plastic and must be replaced with metalic bowls.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2021
Resolved 26 July 2022
Resolution: The on board fuel filters are of an approved type. The deficiency is cleared.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 September 2021
Resolved
Overcharged portable fire extinguisher must be serviced, to bring it back to within acceptable limits.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2021
Resolved 26 July 2022
Resolution: All on board protable fire extinguishers are properly charged and serviced. The deficiency is cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 20 November 2020
Resolved
Vessel is equipped with two (02) 2 person skiffs for lifesaving, total capacity is for four (04) persons. COI is for six (06) total persons. Vessel operations permitted with not more than four (04) total persons on board not more than three (03) miles from shore.
Action required: 705 - Other - as specified
Resolved 28 December 2020
Resolution: The vessel has a CG Approved six (6) person life float on board. Deficiency is cleared.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 November 2020
Resolved
The installed fire detection operation and servicing is unknown. No evidence or record of maintenance and servicing could be presented. Provide evidence of annual servicing and testing prior to operating vessel.
Action required: 30 - Ship detained
Resolved 20 November 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 November 2020
Resolved
Oil storage containers observed in engine room. Flammable and combustible products must not be stored in machinery spaces unless they are stored in a suitable, approved container that meets the requirements of
46 CFR 142.225
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 November 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 13 November 2020
Resolved
Vessel uses a skiff as a survival craft. Skiff does not have a capacity plate to determine if it is capable to accommodate the total number of persons permitted on board IAW the COI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 November 2020
Resolution: two (02) 2 person skiffs satisfactorily installed, vessel linmited to not more than four (04) total persons on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 November 2020
Resolved
Vessel has three (03) Type I Lifejackets on board. Vessel is certificated for 6 total persons. Vessel is restricted to carry not more than three (03) persons on board at any time.
Action required: 705 - Other - as specified
Resolved 20 November 2020
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 13 November 2020
Resolved
Vessel has an installed 406MHz EPRIB that has an expired battery and expired float free device. EPIRB and float free arrangement must be serviced and updated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2020
Resolved 28 December 2020
Resolution: Deficiency is cleared. Battery and flaot free arrangement are satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 November 2020
Resolved
Inadequate quantity of required of Visual Distress Signals on board and one (01) is expired. Provide required quantity of non-expired Visual Distress Signals.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 November 2020
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 13 November 2020
Resolved
Emergency Fuel Stop Valve is located and the water separator assemblies with approximately 8 foot of flexible hose from source to valve. The valve must installed in the fuel piping directly outside of the fuel oil supply tank and capable of being remotely operated.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 November 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 November 2020
Resolved
Fuel Storage Tank Vent Pipe not properly outfitted with appropriate flame screen. vent pipe shall be fitted with a 30-by-30 mesh corrosion-resistant flame screen.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 November 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 13 November 2020
Resolved
No evidence that the fuel system requirements are being met through proper filtration and operation. Provide evidence of a documented fuel system maintenance plan to ensure proper operation of the system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2020
Resolved 28 December 2020
Resolution: Company's fuel maintenance plan has been implemented and acceptable. Deficiency is cleared.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 November 2020
Resolved
No evidence presented that vessels stability is satisfactory for an existing vessel. Provide evidence that vessel stability is satisfactory and that vessel owner and master can attest to satisfactory history, handling characteristics, and operations.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 November 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 November 2020
Resolved
No evidence of Employee Assistance Program (EAP) or display of informational material or hot-line telephone number. Provide evidence of EAP and posting of educational materials and hot-line.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2020
Resolved 4 December 2020
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 13 November 2020
Resolved
No evidence that personnel records, safety orientation for crew members and non-crewmembers, emergency drills and instructions, training requirements, or the identification and mitigation of health and safety hazards or being conducted. Establish Crew Safety requirements in accordance with 46 CFR 140 Subpart D.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2020
Resolved 4 December 2020
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 13 November 2020
Resolved
Installed Automatic Identification System (AIS) does broadcasting correct vessel information. Provide evidence that AIS is broadcasting correct vessel information.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2020
Resolved 28 December 2020
Resolution: AIS is broadcasting correct vessel data. Deficiency is cleared.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 November 2020
Resolved
Port Generator start battery is not properly secured. Secure battery to prevent movement and protect from falling objects.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 November 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 November 2020
Resolved
Electrical Distribution Panels are not properly labeled with current and voltage. Electrical equipment shall me marked with respective current and voltage.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 November 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 November 2020
Resolved
Electrical distribution panel breakers not properly identified. Individual circuit breakers must be labeled with description of correct equipment they serve.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 November 2020
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 13 November 2020
Resolved
No evidence that engine room mechanical ventilation operates or shutdowns properly in an engine fire emergency. Provide proof that ventilation system operates and shutdowns properly and that crew is trained in operation and shutdown procedures.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2020
Resolved 4 December 2020
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 November 2020
Resolved
There is excessive oil accumulation in the engine room bilge, as well as oil soaked rags stuffed in the MDE. Minimize fire hazard to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 13 November 2020
Resolution: Bilges cleaned of accumulated oil and oil soaked rags removed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 10 November 2020
Resolved
There is no Health and Safety Plan in place. Company must draft and implement Safety Plan in accordance with 46CFR140.500
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2020
Resolved 4 December 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 November 2020
Resolved
Life buoys are deteriorated and in need of replacement.
When replaced, two (2) must have approved float lights and one (1) must have required line attached.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 20 November 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 November 2020
Resolved
Type I PFDs must have personal marker lights (PML) and whistles attached and the Type V PFDs must have PMLs.
Action required: 30 - Ship detained
Resolved 13 November 2020
Resolution: Lights and Whistles installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 10 November 2020
Resolved
While there are gauges at the operating station for the Main Diesel Engines, there is only a visual alarm light for the STBD MDE. Install required alarms and monitoring devices IAW 46 CFR 143.230.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2020
Resolved 28 December 2020
Resolution: Deficiency is cleared. Appropriate alarms and monitoring guages are located at the operating station.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 November 2020
Resolved
The fire ax's handle is rotted and in need of replacement.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 13 November 2020
Resolution: Fire Ax Handle replaced.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 10 November 2020
Resolved
An outdated Towing Vessel Record was presented (last entry November 2016) so there is no record of entries documenting required operational events like; Safety Orientations, Crew Training, and Drills, or Navigational Assessments, and changes of watch and crew on board.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2020
Resolved 4 December 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 November 2020
Resolved
Electrical breakers were found taped in the opened position. Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact.
Condition: Improper Installation
Action required: 30 - Ship detained
Resolved 20 November 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 November 2020
Resolved
Attended vessel to conduct an Annual Inspection finding that the COI was invalid since the inspection was two months past its due date, along with multiple administrative , and safety deficiencies. Vessel must complete a satisfactory Annual Inspection prior to movement.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 20 November 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 November 2020
Resolved
No documented evidence of towing equipment is being inspected. Records for towing gear inspections and testing shall be developed and kept in accordance with 46 CFR 140.801, 140.805 and 140.820.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2020
Resolved 28 December 2020
Resolution: The company has implemented an inspection program for their towing gear, and has an appropriate record book in place. Deficiency is cleared.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 8 October 2019
Resolved
System needs reprogramed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2019
Resolved 28 December 2020
Resolution: Deficiency cleared, unit displays proper information.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 October 2019
Resolved
Life jackets and immersion suits need to be labled with the companies name.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2019
Resolved 13 November 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 October 2019
Resolved
Manager was not familiar with how to test alarms and shutdowns.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2019
Resolved 28 December 2020
Resolution: All required alarms and monitoring guages are installed and functioning properly. Vessel's master is familiar with the system's proper use. Deficiency is cleared.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 19 December 2012
Resolved
Company has no record of MIS report submission. 2012 MIS report must be submitted no later than March 15, 2013.
Due 15 March 2013
Resolved 26 February 2013
Resolution: Recieved a copy of the DOT MIS data collection form submitted by Huffman equipment for calender Year 2012. Deficiency cleared.
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 19 December 2012
Resolved
DOT and non-DOT employee random testing are not being maintained in separate pools in accordance with 49 CFR 40.13.
Due 31 January 2013
Resolved 7 February 2013
Resolution: The company has segregated their DOT employees from their marine employees. Deficiency cleared.