Inspection record

Last inspected 9 April 2026
…with no type recorded27
Operational controls None recorded without a removal date
Years with a record 34 calendar years (1986–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WL9622
Flag
UNITED STATES
Tonnage
7945 - Simplified, Gross Ton 7945 - Simplified, Net Ton 7064 - Convention (Subpart B), Gross Ton 7064 - Convention (Subpart B), Net Ton
Maury page id
psix-43392
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 13

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. Only barges and towing vessels are in this archive, so any other vessel type in the same activity does not appear here: these lists are a floor, not a complete manifest.

CAROLINE MCKEE Towing Vessel · MISLE 243656 · 15 June 2025 · activity 8205340MINNESOTA Towing Vessel · MISLE 1812704 · 15 June 2025 · activity 8205340BRADSHAW MCKEE Towing Vessel · MISLE 149766 · 27 July 2012 · activity 4392459PATRICE MCALLISTER Towing Vessel · MISLE 496619 · 1 August 2011 · activity 4101970PATRICE MCALLISTER Towing Vessel · MISLE 496619 · 21 January 2008 · activity 3137463PATRICE MCALLISTER Towing Vessel · MISLE 496619 · 3 September 2007 · activity 3051586PATRICE MCALLISTER Towing Vessel · MISLE 496619 · 20 August 2006 · activity 2755202CALUMET Towing Vessel · MISLE 65871 · 6 February 2006 · activity 2580142SHIRLEY ANN Towing Vessel · MISLE 72164 · 6 February 2006 · activity 2580142PETITE FORTE Towing Vessel · MISLE 404582 · 6 February 2006 · activity 2580142IOWA Towing Vessel · MISLE 56353 · 2 August 2004 · activity 2162753PATRICE MCALLISTER Towing Vessel · MISLE 496619 · 2 August 2004 · activity 2162753PATRICE MCALLISTER Towing Vessel · MISLE 496619 · 1 June 2004 · activity 2084932PATRICE MCALLISTER Towing Vessel · MISLE 496619 · 22 March 2004 · activity 2028914MCKEE SONS Freight Barge · MISLE 62489 · 12 September 2000 · activity 140919INVINCIBLE Towing Vessel · MISLE 174375 · 12 September 2000 · activity 140919STONE EXPLORER Towing Vessel · MISLE 182496 · 1 October 1994 · activity 42113STONE EXPLORER Towing Vessel · MISLE 182496 · 28 August 1994 · activity 184510DAVID E Towing Vessel · MISLE 85943 · 15 October 1993 · activity 188846BENJAMIN RIDGWAY Towing Vessel · MISLE 101426 · 15 October 1993 · activity 188846

Inspection history · 105

9 April 2026 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8345532
25 March 2026 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8332101
5 January 2026 In-Service Inspection · Vessel Attendance
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8290268
15 June 2025 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8205340
10 April 2025 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8109321
25 March 2025 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8099176
7 January 2025 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8059529
23 April 2024 Plan Review (Other than "T") · Construction Oversight · Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7899966
4 March 2024 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7874240
24 January 2024 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7854001
17 November 2023 COI Inspection · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7826460
3 May 2023 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7680122
1 May 2023 Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7678764
27 March 2023 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7657467
25 October 2022 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7583478
29 July 2022 Deficiency Check · Construction Oversight
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7519640
27 May 2022 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7503958
5 April 2022 Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7425182
31 January 2022 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7388171
6 April 2021 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7169442
20 January 2021 Plan Review (Other than "T")
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7127341
13 July 2020 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7005563
24 March 2020 MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6931333
6 March 2020 Administrative Inspection · Plan Review (Other than "T")
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6922139
26 September 2019 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6822075
23 April 2019 Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6670577
12 March 2019 Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6642257
14 January 2019 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6611748
15 March 2017 Internal Structural Exam · Construction Oversight · Administrative Inspection · Initial Certification · Drydock Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6205780
10 January 2017 Load Line/Change of Employment
Administrative · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 6070442
20 February 2014 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 4802563
16 October 2012 Annual Inspection · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 4465413
30 July 2012 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 4395104
27 July 2012 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 4392459
8 June 2012 Damage Survey
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 4337319
8 June 2012 Damage Survey
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 4337906
7 May 2012 Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 4304196
23 January 2012 Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 4230076
7 December 2011 Drydock Extension · Deficiency Check · Construction Oversight · Annual Inspection · Internal Structural Exam
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4214641
13 September 2011 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 4144126
1 August 2011 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4101970
13 June 2011 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 4043147
30 March 2010 MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 3705467
19 May 2009 Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 3479086
4 May 2009 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 3466829
17 April 2008 Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 3186195
21 January 2008 Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3137463
3 September 2007 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3051586
3 January 2007 Hull Examination · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2849674
20 August 2006 Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2755202
6 February 2006 Type not recorded
No type recorded · USCG Great Lakes District (dpb) · USCG Great Lakes District (CGD-GL) · Activity 2580142
22 December 2005 Annual Inspection · MTSA Verification · Drydock Extension
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 2555130
30 September 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2504818
30 March 2005 MTSA Verification · COI Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 2307487
4 December 2004 Damage Survey
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 2253940
12 November 2004 Damage Survey
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2239827
7 November 2004 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2245985
25 October 2004 Damage Survey
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2233143
22 October 2004 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2251558
2 August 2004 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 2162753
16 June 2004 Damage Survey
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2099990
1 June 2004 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 2084932
1 June 2004 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2106906
6 May 2004 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 2060637
6 April 2004 Annual Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 2043955
2 April 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2043886
29 March 2004 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2033365
22 March 2004 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 2028914
21 January 2004 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1989499
5 December 2003 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1959319
28 October 2003 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1937432
8 October 2003 Deficiency Check
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1924075
26 September 2003 Deficiency Check
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1917120
22 August 2003 Periodic Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1875176
14 March 2002 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1493175
15 January 2002 Re-Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1478788
21 December 2000 Damage Survey · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1437810
16 November 2000 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 14245
12 September 2000 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 140919
21 April 2000 COI Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1049069
27 March 2000 Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1393298
27 December 1999 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 677502
24 September 1999 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 82444
19 May 1999 Re-Inspection · Deficiency Check
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1459505
23 April 1998 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1426031
23 June 1997 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1431817
23 January 1997 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1385915
10 April 1996 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1079992
18 November 1995 Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1355573
11 September 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1191480
3 October 1994 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 870485
1 October 1994 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 42113
28 August 1994 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 184510
13 January 1994 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 63226
15 October 1993 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 188846
14 July 1993 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 845782
3 January 1992 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1259300
18 November 1991 Deadweight Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 934665
3 May 1991 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1217579
27 February 1990 Administrative
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1218027
21 February 1990 COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 920632
29 November 1988 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1210549
8 November 1988 Administrative
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 891927
4 June 1988 COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 886906
13 March 1986 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 990255

Deficiency record · 86

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 March 2025 Resolved
The STBD bow rub rail is cracked and needs to be repaired.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2025
Resolved 9 April 2025
Resolution: Section of damaged rail renewed. See photos in activity for details.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 March 2025 Resolved
Remove all non-permanent heat tape applications and provide proper installation IAW with manufacture recommendations throughout barge.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2025
Resolved 9 April 2025
Resolution: Heat tape was removed
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 March 2025 Resolved
Label escape hatches, FWD anchor windlass space to crew locker room, AFT pump room to machinery space.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2025
Resolved 9 April 2025
Resolution: Hatches labeled to aid crew in egress.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 25 March 2025 Resolved
Repair door closure for fire screen door located in control booth in conveyor tunnel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2025
Resolved 9 April 2025
Resolution: Door closure was repaired and reattached.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 March 2025 Resolved
Coiled up cables in the machinery space that were ran through the FWD bulkhead rox box need to be identified as to the purpose and mounted properly.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2025
Resolved 9 April 2025
Resolution: Cables were removed.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 25 March 2025 Resolved
02 AFT and 01 FWD port main deck ventilation door closure gaskets are torn and need to be replace.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2025
Resolved 9 April 2025
Resolution: Gaskets were renewed see photos in documents for details.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 March 2025 Resolved
Provide dedicated electrical outlet for refrigerator located in FWD air castle locker.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2025
Resolved 9 April 2025
Resolution: Outlet was installed for refregerator.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 17 November 2023 Resolved
Electrical Switchboards that are accessible from the rear are required to have rubber mats behind them. Install a proper rubber mat.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 January 2024
Resolution: Rubber mat installed.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 17 November 2023 Resolved
The generator room's boundaries are A-0 and the space must also be reasonably gas tight as it has a fixed suppression system. The cable peentrations in the deck of the aft stbd side have "fire stop" removed and the space is open to the deck below.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2024
Resolved 4 March 2024
Resolution: Examined wire penentrations in area noted above all sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 November 2023 Resolved
Vessel requires house cleaning to remove numerous fire hazards posed by combustible materials such as: wood and cardboard on top of the switchboard; wood & cardboard boxes leaning against and stored next to space heaters; combustible boxes and wood near fuel pumps; other combustible items in close proximity to generators.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 January 2024
Resolution: Crew cleaned and organized the spaces of concern and fire hazards were minimized.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 17 November 2023 Resolved
Breaker panels are required to have each breaker properly labeled. Many panels throughout the vessel are missing labels.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2024
Resolved 4 March 2024
Resolution: Examined all breaker panels throughout barge all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 November 2023 Resolved
All lifebuoys on board require cleaning. Many lifebuoys are missing retro reflective tape. Many require the name of the vessel to be re-stenciled. Lifebuoys with line must be distributed on each side of the vessel. Life buoys with lights may not also have lines.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 January 2024
Resolution: Life rings were corrected for all issues and returned to their stations.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 17 November 2023 Resolved
The start air piping system in the pump room has a relief valve that has been removed from the piping. Provide approved drawing that shows the proper installation and return the system to its approved condition. The engineer reported that the valve kept popping off under normal conditions so it was removed and its connection blanked off. It is possible the relief valve is under sized.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2024
Resolved 14 March 2024
Resolution: 140 psi relief valve installed. O/O provided photo proof.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Other (MARPOL Annex VI)
Issued 27 March 2023 Resolved
Provide copy of annual VGP submission. Most recent onboard was for 2021.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 29 March 2023
Resolved 27 March 2023
Resolution: Copy of 2022 provided prior to completion of exam.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 27 March 2023 Resolved
Properly adjust WTD portside aft gen space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2023
Resolved 27 March 2023
Resolution: Chief engineer adjusted prior to departure and chaulk tested.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 27 March 2023 Resolved
Prove proper operation of all vent closures for tunnel and generator space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2023
Resolved 3 May 2023
Resolution: Statement provided from Chief Engineer cleared outstanding 835
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 March 2023 Resolved
Renew Retro in all Ring Buoys and prove operation of all lights, also place 6 person raft on station.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2023
Resolved 11 April 2023
Resolution: New retro installed, raft placed in craddle.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 27 March 2023 Resolved
Repair 2 fracures on the rub rail starboard side forward.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2023
Resolved 11 April 2023
Resolution: sections of rub rail where cropped and renewed, photo provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 March 2023 Resolved
Properly mark draft marks and Plimsoll marks. Contrasting in color to hull.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2023
Resolved 3 May 2023
Resolution: Photos of hull provided.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 8 April 2022 Resolved
Upper genset room, bottom of L1 Panel, thru deck penetration for cables needs sealant. Replace or install approved sealant.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2022
Resolved 27 May 2022
Resolution: Sealant was applied to cable penetration area below L1 panel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 April 2022 Resolved
Lower genset room, MCC for sewage pump and wash down pump is being modified with remote run/stop switches to be located on upper deck. Provide MCC drawing for modification, complete work, and test function to satisfaction of OCMI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2022
Resolved 29 July 2022
Resolution: PE provided drawing. Installation completed and tested by Hall Electric.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 8 April 2022 Resolved
Port side tunnel ventilation hatch cover on weather deck is missing bottom gasket. Repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2022
Resolved 27 May 2022
Resolution: Gasket material on hatch was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 April 2022 Resolved
Control room in tunnel, at load center 2 (L2), panel has an active ground fault on phase "B" as per indicator. Track down ground fault and make repairs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2022
Resolved 25 October 2022
Resolution: Vessel has disconnected troublesome load L2 ground fault system is operating as intended. Vessel will relay to MSU when suitable solution is ready for review.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 6 April 2021 Resolved
Vessel is prohibited from operating as permissively manned until the following lifesaving deficiencies are resolved: Provide onboard person Solas B raft. Provide onboard an additional 2 Type I adult PFD's. Properly stencil all Ring Buoys Renew Solas retro tape on Ring Buoys Renew Life lines on Ring Buoys. ******AMENDMENT******13APR21 Amended this def to reflect that the operator requested to operate barge using an equivalent life raft in place until new is received. This is only a temporary amendment.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2021
Resolved 27 May 2021
Resolution: Proper raft was installed.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 14 January 2019 Resolved
Make permenent repairs to hole in #6 centerline tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 1 April 2019
Resolution: #6 centerline tank was repaired to the satisfaction of an attending MI.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 7 August 2013 Resolved
The vessel has been placed into long term lay-up. Vessel COI has been de-activated. Vessel shall have a satisfactory Periodic Exam completed for Certificate of Inspection to be re-activated.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 January 2019
Resolution: Major modification completed, name changed to [name withheld] issued.
Construction/Loadline › Hull › Bottom Plating
Issued 16 October 2012 Resolved
Prior to issuance of credit Dry Dock for the vessel, satisfactory completion of work list items detailed in document "[name withheld] Dock Side work list" to be completed to satisfaction of attending Marine Inspector. Drop dead date for credit dry dock is 28 Feb 2013. Work list is scanned to Documents section of activity 4465413.
Action required: 705 - Other - as specified
Due 28 February 2013
Resolved 2 May 2013
Construction/Loadline › Hull › Hull Plating
Issued 8 June 2012 Resolved
Barge suffered 6" stress fracture in #1 Port Ballast Tank and 3" stress fracture in #3 Port Ballast Tank both approximately 10 feet above keel. Complete permanent repairs to stress fractures prior to continuing cargo operations to the satisfaction of the attending CG marine inspector or class surveyor.
Action required: 705 - Other - as specified
Resolved 9 June 2012
Resolution: Rep[airs completed in [name withheld] and witnessed by MSU Cleveland Inspectors. See activity 4337906
Construction/Loadline › Hull › Hull Plating
Issued 7 December 2011 Resolved
After drydocking, a leak was found between old and new plating in the notch in vicinity of frame 46. A cement box was installed approximately 12 feet off center to port, extending approximately 1 foot each side of gusset. Daily soundings are required to be made in after void to ensure integrity of temporary repair and logged. Permanent repair required at next scheduled dry docking.
Action required: 705 - Other - as specified
Due 28 February 2013
Resolved 13 November 2012
Resolution: Repairs effected at cracked weld, after removal of comcrete box. The weld was drill stopped and welded out both sides, as well as 10 feet of washed weld identified during drydocking.
Electrical › Electric Generation Source (service) › Generator
Issued 13 September 2011 Resolved
Permanently affix temp generator box to deck.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 September 2011
Resolved 13 September 2011
Resolution: Rcvd photos of Genset box affixed to deck on bow. Considered sufficient until proven otherwise.
Engineering › Diesel Engine (auxiliary) › Valve
Issued 13 September 2011 Resolved
Rig external fuel shut off valve prior to use.
Action required: 705 - Other - as specified
Resolved 16 September 2011
Resolution: Fuel shut-off was installed.
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 13 September 2011 Resolved
Four portable B-II fire extinguishers must be available in the vicinity of the Generator while in use.
Action required: 705 - Other - as specified
Resolved 16 September 2011
Resolution: Verified the presence of 4 B-11 fire extinguishers.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 13 September 2011 Resolved
Operate Genset only while in port for unloading operations.
Action required: 705 - Other - as specified
Resolved 10 May 2012
Resolution: Tested/Inspected new generator, temp generator removed from vessel.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 13 September 2011 Resolved
Provide remote start/stop for Genst prior to use.
Action required: 705 - Other - as specified
Resolved 16 September 2011
Resolution: Remote start/stop control box was present.
Electrical › Electric Supply System (service) › Cable
Issued 13 September 2011 Resolved
Cable runs to allow for water tight integrity while underway.
Action required: 705 - Other - as specified
Resolved 16 September 2011
Resolution: Verified cable runs were properly run and hung through vessel''s tunnel. Recommended additional chaffing gear and that a member of the crew inspect prior to generator start-up.
Electrical › Electrical Distribution System (service) › Cable
Issued 13 September 2011 Resolved
Generator leads must be permenatly attached at the switchboard prior to use.
Action required: 705 - Other - as specified
Resolved 16 September 2011
Resolution: Cables were properly installed in the vessel''s main switchboard.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 4 May 2009 Resolved
Install electrical safe matting in front of winch control panels for both fwd and aft winch panels.
Action required: 705 - Other - as specified
Due 3 June 2009
Resolved 19 May 2009
Resolution: Sufficient matting was installed as required. Deficiency cleared.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 4 May 2009 Resolved
Found ground detector on 110v distribution panel inoperative. Prove proper operation of ground indicator on 110v distribution panel.
Action required: 705 - Other - as specified
Due 3 June 2009
Resolved 19 May 2009
Resolution: Ground detector found to be in good working order. Deficiency cleared.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 4 May 2009 Resolved
Noted panel MP-3 has open breaker slots. Provide blanks for open breaker spaces.
Action required: 705 - Other - as specified
Due 3 June 2009
Resolved 19 May 2009
Resolution: Open breaker slots on panel were covered with appropriate blanks. Deficiency cleared.
Construction/Loadline › Hull › Hull Plating
Issued 22 December 2005 Resolved
V and weld 6" vertical fracture in bilge knuckle forward starboard side rake.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 December 2005
Resolved 22 December 2005
Construction/Loadline › Hull › Weld
Issued 22 December 2005 Resolved
Repair fractures in welds in tanks top of #4 inner bottom.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 December 2005
Resolved 22 December 2005
Construction/Loadline › Structures › Ventilators
Issued 22 December 2005 Resolved
Replace numerous missing goose neck vent closure devices.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 December 2005
Resolved 22 December 2005
Construction/Loadline › Hull › Bottom Plating
Issued 6 December 2004 Resolved
Crop and renew damaged plate and framing iwo #3 stbd ballast tank frame #2 knuckle.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2004
Electrical › Electric Supply System (service) › Transformer
Issued 12 November 2004 Resolved
Prior to placing the vessel back in service, prove proper operation of all water damaged equipment and provide proof of repair, from an authorized repair facility/shop, for every immersed component.
Condition: Damaged By Earlier Event
Due 1 December 2004
Resolved 3 December 2004
Construction/Loadline › Hull › Hull Plating
Issued 12 November 2004 Resolved
Prior to placing the vessel back in service, determine source of water infiltration and make repairs to the satisfaction of the attending Marine Inspector.
Due 1 December 2004
Resolved 3 December 2004
Stability › Watertight Integrity › General
Issued 12 November 2004 Resolved
A temporary box patch was installed in the #1S ballast tank between # 2 and 3 floor frames. During the next scheduled drydock, ( 31DEC05) the cement box patch and damaged hull plating is to be cropped out and permanently repaired.
Condition: Unknown
Due 14 February 2007
Resolved 17 January 2007
Resolution: Damaged area/cement box was cropped out and renewed.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 12 November 2004 Resolved
Insulate (blanket) both generator's dry exhaust pipes, to the point of termination, in the generator room overhead.
Condition: Unknown
Due 1 March 2005
Resolved 30 March 2005
Resolution: Insulated generator exhaust pipin.
Construction/Loadline › Hull › Hull Plating
Issued 25 October 2004 Resolved
Temporary cement box patch was installed in #1starboard ballast tank between frames 2 & 3. During next scheduled drydock (31 Dec 2005) the cement box and damaged hull plating is to be cropped out with permanent repairs being made to this area.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 December 2005
Resolved 3 December 2004
Engineering › Compressed Air System (start air)
Issued 6 April 2004 Resolved
Prove proper operation of relief valves on air receivers. LEGACY COMPONENT DESC: Receiver/Bottle
Action required: 705 - Other - as specified
Due 7 May 2004
Resolved 6 May 2004
Resolution: Tested relief valves.
Engineering › Diesel Engine (auxiliary)
Issued 6 April 2004 Resolved
Install and prove proper operation of high water temp alarm on Bow Thruster.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2004
Resolved 6 May 2004
Resolution: High water temp alarm tested sat.
Deck/Cargo › Holds/Tanks
Issued 22 August 2003 Resolved
Properly clean, all fuel fill vent flame screens. LEGACY COMPONENT DESC: Flame Arrester
Condition: Improper/Lack of Maintenance
Due 22 September 2003
Resolved 26 September 2003
Resolution: Witnessed Correction
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 22 August 2003 Resolved
Properly mount and number portable fire extinguishers. LEGACY COMPONENT DESC: Mounting Bracket
Condition: Placed in Improper Service
Due 22 September 2003
Resolved 26 September 2003
Resolution: Witnessed Correction
Electrical › Lighting (service)
Issued 22 August 2003 Resolved
Replace missing metal guards on all interior glass globes.
Condition: Improper/Lack of Maintenance
Due 22 September 2003
Resolved 26 September 2003
Resolution: Witnessed Correction
Engineering › Diesel Engine (auxiliary)
Issued 22 August 2003 Resolved
Install guard on bow thruster pulleys. LEGACY COMPONENT DESC: pulley
Condition: Improper/Lack of Maintenance
Due 22 September 2003
Resolved 29 August 2003
Engineering › Thrusters
Issued 22 August 2003 Resolved
Repair hydraulic seal leak on bow thruster pump. LEGACY COMPONENT DESC: Pump
Condition: Unknown
Due 22 September 2003
Resolved 29 August 2003
Engineering › Diesel Engine (auxiliary)
Issued 22 August 2003 Resolved
Ensure proper operation of all safeties on both generators. LEGACY COMPONENT DESC: Overspeed Device
Condition: Damaged By Earlier Event
Due 22 September 2003
Resolved 8 October 2003
Resolution: Witnessed alarms on generators
Electrical › Lighting (service)
Issued 22 August 2003 Resolved
Remove all dead end wires. LEGACY COMPONENT DESC: Conductor
Condition: Improper/Lack of Maintenance
Due 22 September 2003
Resolved 26 September 2003
Resolution: Witnessed Correction
Construction/Loadline › Hull
Issued 22 August 2003 Resolved
Repair all holes (tripping hazards) in the second deck, in any area that is normally accessible by the crew. LEGACY COMPONENT DESC: Bottom Plating
Condition: Improper/Lack of Maintenance
Due 22 September 2003
Resolved 26 September 2003
Resolution: Witnessed correction
Electrical › Lighting (service)
Issued 22 August 2003 Resolved
Install covers on all exposed outlets and motor controllers. LEGACY COMPONENT DESC: Outlet Box
Condition: Improper/Lack of Maintenance
Due 22 September 2003
Resolved 26 September 2003
Resolution: Witnessed Correction
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 22 August 2003 Resolved
Replace bow towline.
Condition: Improper/Lack of Maintenance
Due 22 September 2003
Resolved 22 August 2003
Electrical › Electric Generation Source (service)
Issued 22 August 2003 Resolved
Properly insulate B/T engine and generators dry exhaust. LEGACY COMPONENT DESC: exhaust
Condition: Improper/Lack of Maintenance
Due 22 September 2003
Resolved 26 September 2003
Resolution: Witnessed Correction
Engineering › Diesel Engine (auxiliary)
Issued 22 August 2003 Resolved
Properly insulate bow thruster and generators exhaust piping. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper/Lack of Maintenance
Due 22 September 2003
Resolved 26 September 2003
Resolution: Witnessed Corretion
Deck/Cargo › Cargo Transfer (solid)
Issued 22 August 2003 Resolved
Properly weight test cargo boom. Test must be performed by ABS, International Cargo Gear Bureau or the National Cargo Bureau. Requirement extended untill 31OCT03. Waiting for plans from MSC.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2003
Resolved 8 October 2003
Resolution: Witnessed weight test conducted by International Cargo Gear Bureau.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 12 March 2002 Resolved
Lifebouy lifelines were worn and in need of replacement. Lights needed there own lanyard 3 - 6 foot.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 March 2002
Resolution: Renewed all lines and attached lights with there own lanyards
Construction/Loadline
Issued 27 March 2000 Resolved
MAKE PERMANENT REPAIRS TO THE DOCKING PLUG IN THE #6 STBD VOID._x001C_ _x001C_ REPAIRS ARE TO BE WITNESSED BY A USCG MARINE INSPECTOR.
Condition: Unknown
Due 27 March 2000
Resolved 27 March 2000
Documentation
Issued 19 May 1999 Resolved
PROVIDE COPY OF ORIGINAL COI.
Condition: Unknown
Due 19 May 1999
Resolved 19 May 1999
Lifesaving
Issued 19 May 1999 Resolved
REPAIR OR REPLACE INOPERABLE RING BUOY FLOAT LIGHTS.
Condition: Unknown
Due 1 June 1999
Resolved 25 May 1999
Engineering
Issued 19 May 1999 Resolved
REPLACE REFUELING HOSE DUE TO EXCESSIVE WEAR
Condition: Unknown
Due 1 June 1999
Resolved 25 May 1999
Deck/Cargo
Issued 23 April 1998 Resolved
PERFORM 110% BOOM LOAD TEST OF OFFLOADING BOOM PER N.E. TECHNICAL CO. TEST PROCEDURES.
Condition: Unknown
Due 23 April 1998
Resolved 23 April 1998
Engineering
Issued 23 June 1997 Resolved
REPLACE PLASTIC USED FOR SIGHT GLASSES IN F/O TANK & ANY OTHER FLAMABLE LIQUID TANK, WITH GLASS TUBE & ROD GUARDS.
Condition: Unknown
Due 23 June 1997
Resolved 23 June 1997
Documentation
Issued 23 June 1997 Resolved
VESSEL OPERATIONS ARE SUSPENDED UNTIL AN APPROVED COFR CAN BE OBTAINED ON BOARD.
Condition: Unknown
Due 31 July 1997
Resolved 9 July 1997
Construction/Loadline
Issued 10 April 1996 Resolved
PROVIDE COPY OF ABS REPAIR SURVEY AND CURRENT LOADLINE CERTIFICATE. THE LOADLINE CERTIFICATE MUST BE PROVIDED PRIOR TO VESSEL CERTIFICATION.
Condition: Unknown
Due 25 June 1996
Resolved 12 February 1997
Electrical
Issued 10 April 1996 Resolved
SUPPORT ALL EXISTING WIRING IN RACEWAYS OR WITH METALLIC CLIPS, NO NYLON/PLASTIC TIE WRAPS.
Condition: Unknown
Due 10 April 1996
Resolved 10 April 1996
Electrical
Issued 10 April 1996 Resolved
PROVIDE EVIDENCE OF TESTING OF THE UNLOADING GENERATOR OVERSPEED TRIP AND OTHER SAFETIES TO MANUFACTURERS SPECIFICATIONS BY AN INDEPENDENT SERVICING COMPANY OR TEST IN THE PRESENCE OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 26 May 1996
Resolved 12 February 1997
Fire Fighting
Issued 10 April 1996 Resolved
PROVIDE SIGNED COPY OF FIRE EXTINGUISHER SERVICING REPORT.
Condition: Unknown
Due 26 May 1996
Resolved 12 February 1997
Engineering
Issued 10 April 1996 Resolved
PROVIDE COPY OF BOW THRUSTER INSTALLATION.
Condition: Unknown
Due 10 April 1996
Resolved 10 April 1996
Deck/Cargo
Issued 10 April 1996 Resolved
TEST CARGO GEAR EMERGENCY SHUTDOWN.
Condition: Unknown
Due 10 April 1996
Resolved 10 April 1996
Accommodation/Occupational Safety
Issued 10 April 1996 Resolved
INSTALL NEW RELIEF VALVE ON AIR RECEIVER AND TEST, VALVE MUST RELIEVE AT NOMORE THAN 150 PSI.
Condition: Unknown
Due 26 May 1996
Resolved 26 September 1996
Construction/Loadline
Issued 10 April 1996 Resolved
PROVIDE COPIES OF HULL AND BALLAST PLANS.
Condition: Unknown
Due 10 April 1996
Resolved 10 April 1996
Electrical
Issued 10 April 1996 Resolved
PROVIDE PLANS OF ENTIRE ELECTRICAL SYSTEM FOR COAST GUARD REVIEW. THE ELECTRICAL SYSTEM DESIGN, CONSTRUCTION, AND INSTALLATION MUST BE IN ACCORDANCE WITH 46 CFR PARTS 110 THROUGH 113 (ELECTRICAL ENGINEERING REGS).
Condition: Unknown
Due 10 April 1996
Resolved 10 April 1996
Electrical
Issued 10 April 1996 Resolved
ALL ELECTRICAL PANELS ARE TO BE MARKED TO IDENTIFY ALL CIRCUIYS.
Condition: Unknown
Due 10 April 1996
Resolved 10 April 1996
Electrical
Issued 10 April 1996 Resolved
SECURE AND CLOSE ALL JUNCTION/SWITCH BOXES.
Condition: Unknown
Due 10 April 1996
Resolved 10 April 1996
Deck/Cargo
Issued 10 April 1996 Resolved
PROVIDE LETTER FROM COMPANY IDENTIFYING PERSONNEL AUTHORIZED TO OPERATE/MONITOR CARGO EQUIPMENT AND BALLAST EQUIPMENT/SYSTEM.
Condition: Unknown
Due 26 May 1996
Resolved 12 February 1997
Electrical
Issued 10 April 1996 Resolved
INSTALL BULBS AND FIXTURE COVERS, ALL DECK LIGHTS.
Condition: Unknown
Due 26 May 1996
Resolved 12 February 1997
Deck/Cargo
Issued 10 April 1996 Resolved
PROVIDE PLAN FOR CONDUCTING LOAD TEST OF CARGO BOOM AND CONDUCT 110% SAFE WORKING LOAD TEST IN PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 10 April 1996
Resolved 10 April 1996
Electrical
Issued 10 April 1996 Resolved
THE ENTIRE ELECTRICAL SYSTEM MUST BE COMPLETELY INSTALLED IN ACCORDANCE WITH 46 CFR PARTS 110 - 113 (ELECTRICAL ENGINEERING REGULATIONS) NO LATER THAN 01APR97.
Condition: Unknown
Due 10 April 1996
Resolved 10 April 1996

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.