MAURY USCG vessel records
← All vessels

CAROLINE MCKEE

Built
1972
Last inspected
5 January 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 5 January 2026
…with no type recorded43
Operational controls None recorded without a removal date
Years with a record 28 calendar years (1987–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

7303853
WDK8680
243656
Flag
UNITED STATES
Maury page id
psix-243656

Documentation record

Registered dimensions (L × B × D)128.6 ft × 34.5 ft × 19.0 ft
Registered tonnagegross 169 / net 115
ITC dimensions (L × B × D)128.6 ft × 34.5 ft × 19.0 ft
ITC tonnagegross 565 / net 169
BuilderMAIN IRON WORKS INC · HOUMA, LA, UNITED STATES · built 1972
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMUSKEGON, MI
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 21 August 2025 · expires 30 September 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it169 - Regulatory (Subpart C or D), Gross Ton
565 - Convention (Subpart B), Gross Ton
115 - Regulatory (Subpart C or D), Net Ton
169 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 85 inspections, each with its date, unit and type; 27 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 6 other vessels inspected with it; 2 other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 6

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

COMMANDER Freight Barge · MISLE 43392 · 15 June 2025 · activity 8205340MINNESOTA Towing Vessel · MISLE 1812704 · 15 June 2025 · activity 8205340ALABAMA ENTERPRISE Freight Barge · MISLE 263317 · 19 December 2014 · activity 5046890ALABAMA ENTERPRISE Freight Barge · MISLE 263317 · 10 November 2013 · activity 4755394ALABAMA ENTERPRISE Freight Barge · MISLE 263317 · 27 December 2012 · activity 4512662ALABAMA ENTERPRISE Freight Barge · MISLE 263317 · 28 July 2011 · activity 4102771ALABAMA ENTERPRISE Freight Barge · MISLE 263317 · 20 July 2010 · activity 3801345ALABAMA ENTERPRISE Freight Barge · MISLE 263317 · 11 October 2008 · activity 3343033ALABAMA ENTERPRISE Freight Barge · MISLE 263317 · 25 June 2008 · activity 3260905ALABAMA ENTERPRISE Freight Barge · MISLE 263317 · 22 September 2007 · activity 3064108ALABAMA ENTERPRISE Freight Barge · MISLE 263317 · 16 September 2007 · activity 3070639ALABAMA ENTERPRISE Freight Barge · MISLE 263317 · 27 December 2006 · activity 2850690ALABAMA ENTERPRISE Freight Barge · MISLE 263317 · 25 December 2006 · activity 2850869ALABAMA ENTERPRISE Freight Barge · MISLE 263317 · 3 December 2004 · activity 2254810SALLY Towing Vessel · MISLE 294624 · 3 December 2004 · activity 2254810ALABAMA ENTERPRISE Freight Barge · MISLE 263317 · 31 July 1998 · activity 27592ALABAMA ENTERPRISE Freight Barge · MISLE 263317 · 20 November 1997 · activity 177237JAMES MCALLISTER Towing Vessel · MISLE 176437 · 4 June 1995 · activity 32463ALABAMA ENTERPRISE Freight Barge · MISLE 263317 · 4 June 1995 · activity 32463ALABAMA ENTERPRISE Freight Barge · MISLE 263317 · 9 April 1992 · activity 10155KIRBY 28309 Tank Barge · MISLE 365053 · 9 April 1992 · activity 10155

Inspection history · 85

5 January 2026 In-Service Inspection · Vessel Attendance · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8290260
26 August 2025 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8218690
22 July 2025 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8191843
1 July 2025 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8198273
22 June 2025 Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8164206
16 June 2025 Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8160049
15 June 2025 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8205340
7 January 2025 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8059519
21 October 2024 Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 8022066
8 August 2024 Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7976797
3 April 2024 Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7891631
24 January 2024 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7853990
1 November 2023 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7818521
11 November 2022 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7596336
3 November 2022 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7588379
13 June 2022 Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7477167
31 January 2022 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7388162
8 November 2021 DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7346976
16 August 2021 Administrative Inspection · Damage Survey · Deficiency Check · Examination of Repairs
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7294093
3 August 2020 DAPI Audit · MTSA Verification · Administrative Inspection · Initial Certification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7023309
13 March 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6925948
19 August 2019 Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6788691
13 February 2015 Marine Casualty Follow Up
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5068699
6 February 2015 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5106889
16 January 2015 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5066186
19 December 2014 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5046890
1 June 2014 MTSA/ISPS Verification · Industry Initiated Exam · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4874621
24 April 2014 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4846017
7 April 2014 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4831126
5 April 2014 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4830971
20 February 2014 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4803638
18 February 2014 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4803081
18 February 2014 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4803643
13 January 2014 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4782456
10 November 2013 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4755394
9 March 2013 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4573089
28 December 2012 Administrative Inspection · MTSA/ISPS Verification · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4507665
27 December 2012 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4507601
27 December 2012 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4512662
3 December 2012 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4494955
15 April 2012 Administrative Inspection · Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4287756
12 October 2011 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4166211
29 July 2011 Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4098779
28 July 2011 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4102771
13 July 2011 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4081079
9 July 2011 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4088034
20 April 2011 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3995265
12 April 2011 Industry Initiated Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3984768
22 March 2011 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3973216
22 March 2011 Damage Survey · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4018509
2 March 2011 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3960648
23 February 2011 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3956083
20 July 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3801345
23 June 2010 MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3772402
21 September 2009 Administration
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3603008
21 September 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3615355
16 June 2009 MTSA/ISPS Verification
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3504422
2 June 2009 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3499267
11 October 2008 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3343033
11 October 2008 In-Service Inspection · Uninspected Other
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3343133
25 June 2008 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3260905
17 March 2008 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3167029
26 February 2008 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3153806
23 October 2007 Annual Inspection · MTSA/ISPS Verification · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3176609
23 September 2007 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3064132
22 September 2007 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3064108
16 September 2007 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3070639
27 December 2006 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2850690
25 December 2006 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2850869
28 December 2005 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2557510
27 December 2005 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2556993
3 March 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2302726
27 December 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2265084
3 December 2004 Damage Survey
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2254382
3 December 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2254810
28 June 2004 MTSA/ISPS Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2102713
22 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1978816
19 July 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1665580
10 March 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 44820
31 July 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 27592
20 November 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 177237
26 March 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1099427
4 June 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 32463
9 April 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 10155
13 January 1987 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 501093

Deficiency record · 27

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 March 2026 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Fuel oil drain lines and pre-lube feed lines on vessel main propulsion engines have been changed to flexible hoses, a change from original hard piped OEM installations. With ABS guidance/approval, vessel is permitted to operate with current flexible hose installations. One of the following must be obtained by vessel by due date to continue to operate. 1. Revert to OEM design hard piped installations. 2. Obtain equivalency approval from USCG Marine Safety Center (MSC) for current flexible hose installations. Action 50 code gives vessel 30 days to obtain from date of issued requirement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2026
Resolved 2 April 2026
Resolution: ABS classification approves hose installs. MSC declares no objections to install, equivalency met.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 January 2026 Resolved
MACHINERY AND ELECTRICAL SYSTEMS MUST BE DEGIGNED AND MAINTAINED TO PROVIDE FOR SAFE OPERATION OF THE TOWING VESSEL AND SAFETY OF PERSONS ONBOARD UNDER NORMAL AND EMERGENGCY CONDITIONS. THE FUEL PUMP COVERS FOR BOTH ALCO MAIN ENGINES HAVE BEEN REMOVED AND STORED ASHORE. AlSO,THE ALCO OEM HARD PIPED FUEL AND OIL TUBING LINES HAVE BEEN REMOVED AND REPLACED WITH AFTERMARKET FLEX HOSES. REINSTALL ALL FUEL PUMP COVERS AND GROMMETS. ADDITIONALLY, REMOVE ALL AFTERMARKET FUEL AND OIL HOSES ON THE HEADS OF THE MAIN ENGINES AND REPLACE WITH TUBING AS ORGINALLY DESIGNED BY THE ENGINE MANUFACTURE.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 1 March 2026
Resolved 18 March 2026
Resolution: Fuel pump covers reinstalled. New requirement issued to get OEM install or MSC equivalency for flexible hoses. ABS classes vessel machinery and approves.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 June 2025 Resolved
Propulsion machinery, including main engines must be maintained to ensure proper operation. Vessel reported engineers had to force shutdown stbd main engine following abnormal noises. Shall be rectified within one week. 46 CFR 143.205(c)(1)
Action required: 705 - Other - as specified
Due 22 June 2025
Resolved 22 June 2025
Resolution: STBD main repaired and is operating as designed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 August 2024 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. A flagship thermos device in H/W space is hanging loose, unsecured with no cover, and has excessive cable length. Install to proper regulation.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2024
Resolved 9 September 2024
Resolution: box is properly mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 August 2024 Resolved
02Electrical equipment must be marked with its respective current and voltage rating. Power panel in H/W space needs label. Label power panel.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 8 August 2024
Resolution: Corrected on the spot
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 August 2024 Resolved
Electrical systems and equipment must function properly and minimize system failures and shock hazards. Light switch box in the upper pilot house needs top and bottom plugs installed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2024
Resolved 9 September 2024
Resolution: Knockout plugs installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 August 2024 Resolved
Each wire and cable run must be installed in a manner to prevent contact with personnel, mechanical hazards, and leaking fluids. The H/W space water pumps have power cables laying in drip tray for H/W tank. Install cable run as per regulation.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2024
Resolved 9 September 2024
Resolution: Wiring has been raised and mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 August 2024 Resolved
Electrical components that pose an electrical hazard must be in an enclosure. An electrical box inside the navigation computer cabinet at bridge stairs as exposed conductors, wire nuts and no cover. Tape wire nuts, remove dead ended cables and install cover.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 August 2024
Resolved 9 September 2024
Resolution: Cover installed, dead end wiring removed.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 8 August 2024 Resolved
Each towing vessel must be fitted with a general alarm that sounds in the engine room. The general alarm bell in the upper flat of engine room is non-operable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2024
Resolved 9 September 2024
Resolution: Alarm bell adjusted.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 1 November 2023 Resolved
Replace PORT R/G expansion tank level switch. MI’s found level float and alarm inoperable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2023
Resolved 3 November 2023
Resolution: switch was replaced by ships crew.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 3 November 2022 Resolved
Remove excess oil from engine room bilge. 18” sounded at FWD bilge.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 4 November 2022
Resolution: Excess oil/water was removed from the bilge and dirty oil tank as well.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 3 November 2022 Resolved
Repair hydraulic leak on fitting near pump lower STBD engine room
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2022
Resolved 1 December 2022
Resolution: Leak reported to be fixed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 November 2022 Resolved
Repair fuel leak on cylinder R1 injection pump.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 November 2022
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 3 November 2022 Resolved
Install guard on STBD MDE clutch.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 November 2022
Resolution: STBD MDE clutch guard has been installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 November 2022 Resolved
Properly mount fire extinguisher near lower center ladder of engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 November 2022
Resolution: Fire extinguisher has been properly mounted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 November 2022 Resolved
Troubleshoot and repair oil collection on both generator turbochargers.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 November 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 3 November 2022 Resolved
Install covers on inspection ports on both gensets PORT/STBD.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 December 2022
Resolution: new covers installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 November 2022 Resolved
Dry stores room, remove all un-used electrical wiring and boxes.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 November 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 November 2022 Resolved
Remove all dead end and secure all loose wires in lower bridge AFT elevator space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 November 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 November 2022 Resolved
Provide approval for potable water and OWS system installs in pump room and engine room.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 November 2023
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 November 2022 Resolved
Upper amber towing light (Main) and back up lights are both extinguished. Vessel is restricted from conducting stern tows.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2022
Resolved 1 November 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 3 November 2022 Resolved
Mark all watertight doors and hatches with “ watertight hatch/ water tight door, Keep closed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 November 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 November 2022 Resolved
Properly mount spare fire extinguishers stowed in the fore peak.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 November 2022
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 3 November 2022 Resolved
Repair/make operational, All fuel valves prior to movement.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2022
Resolution: Corrected on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 November 2022 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 November 2022
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 3 November 2022 Resolved
Provide splints onboard the vessel as part of the First aid kit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 November 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 June 2022 Resolved
Modifications were made to the SSDG cooling system without submission or approval of plans.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2022
Resolved 31 August 2022

Recorded names · 2

SHARON DEHART (1995–2013), COASTAL 303 (2013–2014). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.