Records from 1985 to 2016. Most recent: inspection, 5 April 2016.
Inspection history · 99
5 April 2016
In-Service Inspection · Administrative Inspection · Load Line/Change of Employment
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5847452
19 December 2014
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5046890
8 August 2014
MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4948255
22 November 2013
Damage Survey · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4757535
10 November 2013
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4755394
24 September 2013
Examination of Repairs · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4722163
7 June 2013
Periodic Inspection · MARPOL Annex I Examination · Drydock Exam · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4613545
27 December 2012
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4512662
27 November 2012
Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4494813
2 July 2012
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4359865
1 May 2012
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4308468
24 August 2011
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4125922
16 August 2011
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4117436
28 July 2011
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4102771
30 September 2010
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3860404
12 August 2010
Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3822770
11 August 2010
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3821873
20 July 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3801345
10 April 2010
Administrative Inspection · MARPOL Annex I Examination · Internal Structural Exam · COI Inspection · Drydock Exam · MARPOL Annex VI Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3721228
26 January 2010
Annual Inspection · Drydock Extension · Administrative Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3669557
13 August 2009
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3564235
14 May 2009
Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3464283
9 April 2009
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3444997
24 March 2009
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3427506
11 October 2008
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3343033
25 June 2008
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3260905
5 March 2008
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3158900
17 December 2007
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3119021
24 October 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3086096
23 October 2007
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3085958
22 September 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3064108
16 September 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3070639
23 May 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2938422
22 May 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2937094
27 December 2006
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2850690
25 December 2006
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2850869
25 May 2006
Administrative Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2658762
23 January 2006
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2571468
20 January 2006
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2570968
9 January 2006
MARPOL Annex I Examination · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2563691
17 May 2005
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2375881
20 April 2005
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2338779
7 April 2005
Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2322100
3 March 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2302727
18 January 2005
Hull Examination · Administrative Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2276370
3 December 2004
Damage Survey
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2254233
3 December 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2254810
28 June 2004
MTSA/ISPS Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2102725
3 February 2004
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1999477
22 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1978821
18 February 2003
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1746019
21 January 2003
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1731232
5 September 2002
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1671326
29 January 2002
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1483648
6 December 2001
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1432597
23 February 2001
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1058485
26 January 2001
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1056746
25 January 2001
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1397560
3 April 2000
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1047375
10 February 2000
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1426327
24 September 1999
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1388840
29 January 1999
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1454627
31 July 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 27592
15 May 1998
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1433350
19 February 1998
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1390718
20 November 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 177237
25 March 1997
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1396739
20 May 1996
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1380521
25 June 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1432918
4 June 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 32463
4 June 1995
Damage Survey
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1440941
26 May 1995
Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1459941
12 January 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 664416
28 October 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 28777
25 May 1994
Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 862870
10 November 1993
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1154419
1 October 1993
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 848027
7 August 1993
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 830011
16 July 1993
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1157432
2 September 1992
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 961715
4 August 1992
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 939258
9 April 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 10155
25 March 1992
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 945817
20 February 1992
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1306021
11 December 1991
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1261795
6 December 1991
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1257588
12 August 1991
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1247519
12 August 1991
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1247948
8 August 1990
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 900864
30 January 1990
Examination of Repairs
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 931011
9 November 1989
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1215467
24 August 1989
Hull Examination · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 895840
22 September 1988
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1196069
13 June 1988
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1205868
2 June 1988
Hull Examination · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 895150
18 June 1987
COI Inspection · Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1002577
13 March 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1322532
20 January 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1317293
20 December 1985
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1304268
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 7 June 2013
Resolved
Light panel P401-1 which is located in the fwd machinery space has a faulty ground detection system. Repair ground detection system and ensure no partial grounds exist on associated lighting system. Ensue panel directory card is updated.
Action required: 705 - Other - as specified
Due 6 September 2013
Resolved 15 August 2013
Resolution: Received reviewed and accepted tech, Garba Industrial Service, Inc., report attesting to proper repair of the panel ground detection system.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 7 June 2013
Resolved
#1 and #2 main diesel generator's over speed shutdown device could not be tested properly due to no means of verifying engine RPM. Also low lube oil shutdown could not be properly tested due to lack of testing equipment (jumping the switch was not accepted). Provide RPM gauge to prove proper operation of both over speed devices and test lube oil shutdowns.
Action required: 705 - Other - as specified
Due 6 September 2013
Resolved 15 August 2013
Resolution: Received reviewed and accepted tech, C&M Engine Services, report attesting to proper testing of the both MDG shutdowns. Report scanned into documents.
Deck/Cargo › Ballast › Pumps
Issued 7 June 2013
Resolved
Determine cause of excessive water leak coming from between the port ballast pump's base mount gasket area. Effect repairs as necessary.
Action required: 705 - Other - as specified
Due 6 September 2013
Resolved 24 September 2013
Resolution: Met with the Chief Engineer and witnessed repairs to the port ballast pump''s excessive water leak. Additionally a drainage hose was added from the collection area leading to the main deck.
Electrical › Lighting (service) › Lighting Fixture
Issued 7 June 2013
Resolved
Replace holed cover to light fixture located above the #1 Maine Diesel Generator.
Action required: 705 - Other - as specified
Due 6 September 2013
Resolved 15 August 2013
Resolution: Received, reviewed and accepted tech, Garba Industrial Service, Inc., report attesting to replacement of light cover.
Engineering › Pressure Vessel › Relief Valve
Issued 7 June 2013
Resolved
Relief valve on the air receiver located in the fwd machinery room did not relieve at the set point of 175 psi. Replace or repair faulty relief valve installed on the air receiver.
Action required: 705 - Other - as specified
Due 6 September 2013
Resolved 24 September 2013
Resolution: Replaced existing relief valve with a 150psi relief valve and witnessed a satisfactory relief upon pressurization.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 7 June 2013
Resolved
Main switch board panel, associated to the #2 main diesel generator, has faulty ground detection system, wattage and amperage meter. Make proper repairs to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 6 September 2013
Resolved 15 August 2013
Resolution: Received, reviewed and accepted tech, Garba Industrial Service, Inc., report attesting to proper repair of the main switchboard ground detection system.
Accommodation/Occupational Safety › Heating › Electric Air Heating Equipment
Issued 7 June 2013
Resolved
Exposed wires found on the electric heater vent's control unit, located in the fwd machinery space, due to broken plastic house cove. Replace cover or remove the control unit eliminating the electrical hazard.
Action required: 705 - Other - as specified
Due 6 September 2013
Resolved 15 August 2013
Resolution: Exposed wires to the in operable heater control unit made safe. Entire system will be removed in near future.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 7 June 2013
Resolved
Provide proper drain plugs on the small discharge containment to the fuel transfer system located on aft deck.
Action required: 705 - Other - as specified
Due 6 September 2013
Resolved 23 August 2013
Resolution: Small discharge containment repaired and plugs added.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 27 November 2012
Resolved
Due to vessel losing its anchor while in transit to Port of Tampa, vessel must be provided with a serviceable anchor. IAW 46CFR32.15-15.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2012
Resolution: Witnessed finished installation of new anchor.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 27 November 2012
Resolved
Because of the vessel's inability to have the anchors ready for letting go, the entire transit through the Port of Tampa must be conducted during daylight hours. IAW 46CFR 164.11(o).
Action required: 705 - Other - as specified
Resolved 2 December 2012
Resolution: Restriction removed, anchor properly replaced.
Construction/Loadline › Hull › Bottom Plating
Issued 12 August 2010
Resolved
The repair of the crack iwo aft flume tank is a temporary repair. As such if the vessel sustains any further damage, it shall immediately notify the local OCMI and proceed to dry dock for inspection and proper repairs. 46 CFR 91.27-15
Action required: 705 - Other - as specified
Resolved 6 August 2013
Resolution: Vessel completed full dry dock in [name withheld], MX. MI and local ABS surveyor witnessed proper repairs to temporary repaired crack iwo the aft flume tank.
Construction/Loadline › Hull › Bottom Plating
Issued 12 August 2010
Resolved
The vessel shall proceed to dry dock to make repairs no later than 31MAY2011. 46 CFR 91.27-15
Action required: 705 - Other - as specified
Due 31 May 2011
Resolved 21 September 2010
Resolution: Requirement has been cleared after appeal from owner.
Construction/Loadline › Hull › Bottom Plating
Issued 12 August 2010
Resolved
The vessel shall report to this office by the first day of each month until proper repairs have been made, that the repair has been inspected and its condition. These inspections shall take place before, during, and after cargo operations to ensure the seaworthiness of the vessel. 46 CFR 91.27-15
Action required: 705 - Other - as specified
Resolved 6 August 2013
Resolution: Vessel completed full dry dock in [name withheld], MX. MI and local ABS surveyor witnessed proper repairs. Full credit dry dock and ISE completed.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 10 April 2010
Resolved
Anchor windlass not operable. Vessel to remain moored at TNG Shipyard, Veracruz until anchor windlass tested SAT by ABS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2010
Resolution: Anchor windlass tested SAT by ABS Surveyor [name withheld]
Engineering › Thrusters › Motor
Issued 10 April 2010
Resolved
Bow thruster not operational. Programable Logic Controller will be programmed back in Tampa, FL.
Action required: 705 - Other - as specified
Due 20 June 2010
Resolved 11 April 2011
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 24 March 2009
Resolved
1. To be completed prior to 15April09, On the main switchboard, determine that the breakers are correct fo rthe circuit and make sure data plate is correct. Currently numerous breakers do not match data -plates.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 April 2009
Resolved 30 April 2009
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 24 March 2009
Resolved
2. To be completed prior to 15April09: Check all panel boxes throughout the barge and draft new directories to reflect current breakers and amp load.
Action required: 705 - Other - as specified
Due 15 April 2009
Resolved 30 April 2009
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 24 March 2009
Resolved
3. To be completed prior to 15April09: Mooring and anchor windlass fuses are of the renewable link type. Remove and replace with the proper one time fuse.
Action required: 705 - Other - as specified
Due 15 April 2009
Resolved 30 April 2009
Stability › Watertight Integrity › Weathertight Enclosure
Issued 23 October 2007
Resolved
Replace missing gasket for vent door on port side aft side of focsle at #2 generator. Upon completion of next dry-dock.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 December 2007
Resolved 17 December 2007
Documentation › Certificates/Documents › Certificate of Inspection
Issued 23 October 2007
Resolved
Vessels annual inspection was due 3 months before or after 9JAN07 and was not conducted until more than 5 months past the 3 month window.
Due 23 October 2007
Resolved 23 October 2007
Resolution: Vessels annual inspection completed and NOV will be issued to company for failure to complete an annual inspection within 3 months before or after the anniversary date of the COI..
Engineering › Fuel Oil Service System › Vent Pipe
Issued 23 October 2007
Resolved
Replace missing flame screen on stbd aft L/O tank vent. Upon completion of next dry-dock.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 December 2007
Resolved 17 December 2007
Electrical › Electric Generation Source (service) › Ground Indicator
Issued 23 October 2007
Resolved
Find and fix partial ground on 110 side in port aft house. Upon completion of next dry-dock.
Action required: 705 - Other - as specified
Due 31 December 2007
Resolved 21 December 2007
Electrical › Electric Supply System (service) › Cable
Issued 23 October 2007
Resolved
General wiring needs to be properly secured (tie downs broken and wasted). Upon completion of next drydock.
Action required: 705 - Other - as specified
Due 31 December 2007
Resolved 17 December 2007
Stability › Watertight Integrity › Weathertight Enclosure
Issued 23 October 2007
Resolved
Repair broken dog on vent door to port side generator #1 on aft side of focsle. Upon completion of next dry-dock.
Action required: 705 - Other - as specified
Due 31 December 2007
Resolved 17 December 2007
Lifesaving › Lifebuoys › Serviceable
Issued 23 October 2007
Resolved
General ensure all ring buoys have proper retro tape, correct name, and working lights. Upon completion of next dry dock.
Action required: 705 - Other - as specified
Due 31 December 2007
Resolved 17 December 2007
Engineering › Fuel Oil Service System › Piping
Issued 23 October 2007
Resolved
Examine and replace if needed F/O return line on the #1 generator through deck fitting. Upon completion of next dry-dock.
Action required: 705 - Other - as specified
Due 31 December 2007
Resolved 17 December 2007
Engineering › Electric Propulsion System › Battery Charging Circuitry
Issued 23 October 2007
Resolved
Install inline fuse on positive lead to thruster control for bow thruster. upon completion of next dry-dock.
Action required: 705 - Other - as specified
Due 31 December 2007
Resolved 21 December 2007
Engineering › Fuel Oil Service System › Filter
Issued 23 October 2007
Resolved
Replace missing flame impingement bowl on aux generator #3. Upon completion of next dry-dock.
Action required: 705 - Other - as specified
Due 31 December 2007
Resolved 17 December 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 23 October 2007
Resolved
Permanently install oxygen bottles for welding in fwd compartment. Upon completion of next dry-dock.
Action required: 705 - Other - as specified
Due 31 December 2007
Resolved 17 December 2007
Engineering › Fuel Oil Service System › Hose
Issued 23 October 2007
Resolved
Properly identify two hoses on vessel and provide proof of annual fuel hose test. Upon completion of next dry-dock.
Action required: 705 - Other - as specified
Due 31 December 2007
Resolved 17 December 2007
Resolution: Three new hoses supplied and tested.
Engineering › Fuel Oil Service System › Piping
Issued 23 October 2007
Resolved
Conduct annual test on F/O piping last test conducted on 1/6/06. Upon completion of next dry-dock.
Action required: 705 - Other - as specified
Due 31 December 2007
Resolved 17 December 2007
Lifesaving › Lifebuoys › Quantity
Issued 9 January 2006
Resolved
Provide vessel with the appropriate number of life rings as per the COI.
Action required: 705 - Other - as specified
Due 9 February 2006
Resolved 20 January 2006
Resolution: Four life rings provided. Work order for additional two provided to Marine Inspector.
Engineering › Fuel Oil Service System › Hose
Issued 9 January 2006
Resolved
Replace the fuel hose on the No. 1 Generator, existing arrangement is two hose coupled together.
Action required: 705 - Other - as specified
Due 9 February 2006
Resolved 20 January 2006
Resolution: New fuel hose installed.
Engineering › Fuel Oil Service System › Valve, Control
Issued 9 January 2006
Resolved
Provide a handle for the fuel valve on the No. 3 Generator.
Action required: 705 - Other - as specified
Due 9 February 2006
Resolved 20 January 2006
Resolution: Handle installed.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 9 January 2006
Resolved
Repair the air damper linkage on the No. 1 Generator, linkage is binding up and is not reliable for shut downs.
Action required: 705 - Other - as specified
Due 9 February 2006
Resolved 20 January 2006
Resolution: Linkage repaired and tested.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 7 April 2005
Resolved
Prove proper operation of the Number 2 Generator control panel.
Condition: Unknown
Due 7 May 2005
Resolved 17 May 2005
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 7 April 2005
Resolved
Prove proper operation of the bow thruster engine and shutdowns.
Condition: Unknown
Due 7 May 2005
Resolved 3 June 2005
Construction/Loadline › Hull › Side Shell
Issued 3 December 2004
Resolved
Provide copy of class survey report attesting to the structural integrity and any damage sustained to the O/B DORIS GUENTHER.
Due 6 December 2004
Resolved 4 December 2004
Resolution: Received ABS report stating the following: "Collision bhd inset approximately 8", port side, between 3rd longitudinal from upper deck to 1st stringer. Recommend repair at first available port to the attending surveyors satisfaction."
Construction/Loadline › Hull › Side Shell
Issued 3 December 2004
Resolved
Notify [name withheld] upon arrival to coordinate inspection of repairs made to vessel as stated in ABS class surveyors report dated 05DEC04.
Due 21 December 2004
Resolved 15 December 2004
Resolution: Permanent repair to be completed at next drydocking (NLT 29OCT07) as per ABS survey report.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 3 February 2004
Resolved
GOOSE NECK VENT FOR #1 CARGO TANK DOUBLE BOTTOM WASTED ON STBD SIDE. RENEW VENT PIPE DURING NEXT SCHEDULED DRY DOCK OR PRIOR TO 24 SEP 2004.
Due 24 August 2004
Resolved 10 October 2004
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 18 February 2003
Resolved
Submit repair proposal to cognizant OCMI and make repairs to wasted areas (per gauging report) of the sludge tank on aft stbd main deck at next class drydocking period.
Condition: Improper/Lack of Maintenance
Due 24 September 2004
Resolved 10 October 2004
Engineering › Fuel Oil Storage/Transfer System
Issued 21 January 2003
Resolved
Gauge wasted sections of starboard slop tank @ bottom about half way from front and also gauge weld seam at top forward section of tank. LEGACY COMPONENT DESC: Tank
Due 21 February 2003
Resolved 18 February 2003
Electrical › Electrical Distribution System (service)
Issued 21 January 2003
Resolved
Replace shielding to electrical wires at the forward port side of cargo hold #3 cable and cable in the after port side cargo hold #2 were the shilding material is damaged. LEGACY COMPONENT DESC: Cable
Due 21 February 2003
Resolved 18 February 2003
Deck/Cargo › Ballast
Issued 29 January 2002
Resolved
MAKE REPAIR TO PORT AND STARBOARD BALLAST PUMP SHAFT PACKINGS WHERE LEAKING EXCESSIVELY. LEGACY COMPONENT DESC: Pumps
Condition: Improper/Lack of Maintenance
Due 5 February 2002
Resolved 29 January 2002
Resolution: BOTH LEAKING SHAFT PACKINGS WERE TIGHTENED AND THE EXCESSIVE LEAKING WAS STOPPED PRIOR TO THE COMPLETION OF THE INSPECTION.
Deck/Cargo › Ballast
Issued 29 January 2002
Resolved
REMOVE CORROSION FROM GOOSENECK VENT FOR DOUBLE BOTTOM BALLAST TANK #2. LEGACY COMPONENT DESC: Vents
Condition: Improper/Lack of Maintenance
Due 28 February 2002
Resolved 29 January 2002
Resolution: RUST BLOCKED VENT. VENT WAS CLEANED PRIOR TO THE COMPLETION OF THE INSPECTION.
Electrical › Lighting (service)
Issued 29 January 2002
Resolved
REPAIR/REPLACE WIRING ON BATTERIES IN HOUSE (AFT PORT SIDE), TERMINALS WERE SEVERLY CORRODED AND REPLACE WING NUTS WITH HEX NUTS. LEGACY COMPONENT DESC: Conductor
Condition: Improper/Lack of Maintenance
Due 28 February 2002
Resolved 5 February 2002
Resolution: WIRING WAS REPLACED AND HEX NUTS WERE INSTALLED ON THE BATTERY TERMINALS.
Engineering › Fuel Oil Service System
Issued 29 January 2002
Resolved
INSTALL FLAME BOWL ON FUEL STRAINER MOUNTED ON GANTRY CRANE. LEGACY COMPONENT DESC: Filter
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2002
Resolved 5 February 2002
Resolution: FLAME BOWL WAS INSTALLED ON FUEL STRAINER.
Construction/Loadline
Issued 25 January 2001
Resolved
Clean out the gooseneck for the vent at #2P.
Condition: Unknown
Due 25 February 2001
Resolved 26 January 2001
Electrical
Issued 25 January 2001
Resolved
Repair the wiring for the 24V battery for the bow thruster.
Condition: Unknown
Due 25 February 2001
Resolved 26 January 2001
Electrical
Issued 25 January 2001
Resolved
Prove the proper operation of the auxiliary generator (place on line).
Condition: Unknown
Due 25 February 2001
Resolved 26 January 2001
Electrical
Issued 25 January 2001
Resolved
Lock the access to the back of the switchgear.
Condition: Unknown
Due 25 February 2001
Resolved 26 January 2001
Electrical
Issued 25 January 2001
Resolved
Provide a cover for the 480V cargo light panel within the machinery room.
Condition: Unknown
Due 25 January 2001
Resolved 25 January 2001
Lifesaving
Issued 25 January 2001
Resolved
Secure the loose gas cylinders in the forward storage area.
Condition: Unknown
Due 25 February 2001
Resolved 26 January 2001
Lifesaving
Issued 25 January 2001
Resolved
store the flammables (in the fwd storage) in the paint locker.
Condition: Unknown
Due 25 February 2001
Resolved 26 January 2001
Electrical
Issued 25 January 2001
Resolved
Remove the old wiring in way of #3p.
Condition: Unknown
Due 25 February 2001
Resolved 26 January 2001
Electrical
Issued 25 January 2001
Resolved
Remove the multiconductor cable on the stbd side in the machinery room above the batteries.
Condition: Unknown
Due 25 February 2001
Resolved 26 January 2001
Deck/Cargo
Issued 25 January 2001
Resolved
Fix the hydraulic leak on the stbd hydraulic motor for the hatch cover crane.
Condition: Unknown
Due 25 January 2001
Resolved 25 January 2001
Engineering
Issued 10 February 2000
Resolved
PROVIDE MEANS AND PROVE PROPER OPERATION OF LOW LUBE OIL SHUTDOWN ON EACH SSDG PRIME MOVER.
Condition: Unknown
Due 10 February 2000
Resolved 10 February 2000
Engineering
Issued 10 February 2000
Resolved
PROVE PROPER OPERATION OF HIGH WATER JACKET TEMPERATURE ALARM ON EACH SSDG PRIME MOVER.
Condition: Unknown
Due 10 February 2000
Resolved 10 February 2000
Engineering
Issued 10 February 2000
Resolved
REMOVE PETCOCKS FROM AND PLUG ALL IMPINGEMENT BOWLS FOR RAYCOR FUEL FILTERS
Condition: Unknown
Due 10 February 2000
Resolved 10 February 2000
Electrical
Issued 10 February 2000
Resolved
REMOVE DEADEND WIRE FOR BOW THRUSTER ALARM TO EXPANSION TANK NO LONGER IN SERVICE
Condition: Unknown
Due 10 February 2000
Resolved 10 February 2000
Electrical
Issued 10 February 2000
Resolved
RENEW AMMETER COVER AND HOUSING FOR #1, #2 AND AUX GENERATOR ON MAIN SWITCHBOARD.
Condition: Unknown
Due 10 February 2000
Resolved 10 February 2000
Electrical
Issued 10 February 2000
Resolved
REPAIR LIGHT FOR CENTER PANEL OF MAIN SWITCHBOARD.
Condition: Unknown
Due 10 February 2000
Resolved 10 February 2000
Electrical
Issued 10 February 2000
Resolved
REMOVE DEADEND WIRE IWO JUNCTION BOX ON FORWARD MAST.
Condition: Unknown
Due 10 February 2000
Resolved 10 February 2000
Electrical
Issued 10 February 2000
Resolved
REPAIR DOOR ON 480V-3 PHASE PANEL IN STOREROOM.
Condition: Unknown
Due 10 February 2000
Resolved 10 February 2000
Electrical
Issued 10 February 2000
Resolved
BLANK OFF OPENING IN FACE OF 480V-3 PHASE PANEL.
Condition: Unknown
Due 10 February 2000
Resolved 10 February 2000
Electrical
Issued 10 February 2000
Resolved
INSTALL LIGHT BULB COVER IN INDICATOR PANEL ABOVE 480V-3 PHASE ELECTRIC PANEL.
Condition: Unknown
Due 10 February 2000
Resolved 10 February 2000
Lifesaving
Issued 10 February 2000
Resolved
REMOVE ALL FLAMMABLE MATERIAL FROM STOREROOM.
Condition: Unknown
Due 10 February 2000
Resolved 10 February 2000
Engineering
Issued 29 January 1999
Resolved
Prove operation of 3-71 GenSet low oil shutdown and high temperature alarm to attending inspectors satisfaction.
Condition: Unknown
Due 3 March 1999
Resolved 3 March 1999
Engineering
Issued 25 March 1997
Resolved
CONDUCT HYDRO TEST OF ALL ABOVE DECK BUNKER PIPING TO 1.5 MAWP.
Condition: Unknown
Due 29 May 1997
Resolved 29 May 1997
Unknown
Issued 25 March 1997
Resolved
PROVE COMPLIANCE WITH RANDOM DRUG/ALCOHOL TESTING PER 46 CFR 16.
Condition: Unknown
Due 29 May 1997
Resolved 29 May 1997
Engineering
Issued 20 May 1996
Resolved
FLAME SCREENS NOT INSTALLED IN P AND S FUEL TANK VENTS.
Condition: Unknown
Due 20 May 1996
Resolved 31 May 1996
Construction/Loadline
Issued 26 May 1995
Resolved
PROVIDE AND INSTALL VISUAL INDICATORS OF WHETHER VALVES ON MAIN DECK AND MACHINERY SPACE ARE OPEN OR CLOSED.
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Lifesaving
Issued 26 May 1995
Resolved
PROVIDE AND INSTALL AN AUDIBLE WARNING DEVICE ON GANTRY CRANE TO INDICATE CRANE MOVEMENT.
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Deck/Cargo
Issued 26 May 1995
Resolved
PROVIDE AND INSTALL LOW-OIL-PRESSURE AUDIBLE AND VISUAL ALARMS FOR BOW THRUSTER ENGINE (CAT D398).
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
System not recorded
Issued 28 October 1994
Resolved
CONDENSATION FROM THE VESSEL'S WATER PUMPS COLLECTED AND RAN INTO THE PUMP ENGINE CONTAINMENT AREA. THE CONTAINMENT AREA CONTAINED WASTE OIL AND SPILLED OUT A HOLE ONTO THE VSL'S DECK AND DOWN THE STARBOARD SIDE. THE WASTE OIL/WATER THEN FLOWED OVER THE SIDE AND ONTO THE WATERS OF EAST BAY.
Condition: Unknown
Due 26 December 2001
Resolved 26 December 2001
Construction/Loadline
Issued 16 July 1993
Resolved
DEMONSTRATE WEATHER-TIGHTNESS OF ALL CARGO HATCHES TO THE SATISFACTION OF AN ATTENDING U. S. COAST GUARD INSPECTOR.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Electrical
Issued 16 July 1993
Resolved
REPLACE MISSING COVERS TO ELECTRICAL JUNCTION BOXES LOCATED STBD SIDE OF FOUCLE AND STBD SIDE AFT IN VICINITY OF BITT.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Electrical
Issued 16 July 1993
Resolved
DEMONSTRATE PROPER OPERATION OF ALL DIESEL GENERATOR ALARMS AND SHUTDOWNS TO THE SATISFACTION OF AN ATTENDING U. S. COAST GUARD INSPECTOR.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Deck/Cargo
Issued 16 July 1993
Resolved
MAKE AIR RECEIVER AVAILABLE FOR INTERNAL INSPECTION TO AN ATTENDING U. S. COAST GUARD INSPECTOR.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Electrical
Issued 16 July 1993
Resolved
REPLACE MISSING FAN GUARD ON GANTRY ELECTRIC MOTOR.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Documentation
Issued 24 August 1989
Resolved
DRYDOCK DUE 24AUG94. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Condition: Unknown
Due 24 August 1989
Resolved 24 August 1989
Documentation
Issued 24 August 1989
Resolved
PROVIDE LETTER FROM ABS STATING THAT ALL OUTSTANDING REQUIREMENTS PERTAINING TO VESSEL CONVERSION HAVE BEEN SATISFIED.
Condition: Unknown
Due 24 August 1989
Resolved 24 August 1989
Documentation
Issued 2 June 1988
Resolved
MAKE DRAFT MARKS AND LOADLINE LEGIBLE.
Condition: Unknown
Due 2 June 1988
Resolved 2 June 1988
Accommodation/Occupational Safety
Issued 2 June 1988
Resolved
MAKE PERMANENT REPAIRS TO HANDRAILS.
Condition: Unknown
Due 2 June 1988
Resolved 2 June 1988
Construction/Loadline
Issued 2 June 1988
Resolved
REPLACE HANDWHEEL ON DROP VALVE TO #3 STBD WING TANK.
Condition: Unknown
Due 2 June 1988
Resolved 2 June 1988
Electrical
Issued 2 June 1988
Resolved
REMOVE OR PROPERLY AFFIX DEAD ENDED CABLE AT AFT MAST.
Condition: Unknown
Due 2 June 1988
Resolved 2 June 1988
Construction/Loadline
Issued 2 June 1988
Resolved
MAKE REPAIRS TO DOGS AND HINGE ON PORT AFT FLUME TANK HATCH.
Condition: Unknown
Due 2 June 1988
Resolved 2 June 1988
Electrical
Issued 2 June 1988
Resolved
REPLACE STUFFING TUBE TO PORT RUNNING LIGHT ON FORECASTLE DECK PENETRATION.
Condition: Unknown
Due 2 June 1988
Resolved 2 June 1988
Electrical
Issued 2 June 1988
Resolved
INSTALL FORWARD RANGE LIGHT WIRING IN PROPER CABLE RUNS.
Condition: Unknown
Due 2 June 1988
Resolved 2 June 1988