BRADSHAW MCKEE

Built
1977
Last inspected
28 July 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 28 July 2026
…with no type recorded22
Operational controls None recorded without a removal date
Years with a record 31 calendar years (1992–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

7644312
WDF7733
149766
Flag
UNITED STATES
Maury page id
psix-149766

Documentation record

Registered dimensions (L × B × D)113.2 ft × 34.2 ft × 11.7 ft
Registered tonnagegross 174 / net 118
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTOCHE ENTERPRISES INC · N OCEAN SPRINGS, MS, UNITED STATES · built 1977
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMUSKEGON, MI
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 18 September 2025 · expires 30 September 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it174 - Regulatory (Subpart C or D), Gross Ton
118 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 52 inspections, each with its date, unit and type; 28 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 3 other vessels inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 3

Inspection history · 52

28 July 2026 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8449428
19 May 2025 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8139300
8 May 2024 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7908513
6 February 2024 Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7862002
21 June 2023 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7720341
18 May 2023 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7691361
29 April 2022 Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 7440780
18 April 2022 Deficiency Check · COI Inspection · MTSA Verification · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7433418
11 March 2022 Examination of Repairs
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7411443
23 March 2020 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6928107
17 April 2019 Bulk Liquid Transfer Monitor
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6664491
12 March 2019 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6641129
27 June 2018 DAPI Audit · In-Service Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6469318
15 May 2018 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6415122
23 August 2017 Bulk Liquid Transfer Monitor
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6253666
4 March 2016 Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 5827074
16 September 2015 Load Line
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5720721
24 June 2015 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5163923
16 May 2014 Administration
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4860225
2 May 2014 Load Line/Change of Employment
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 4850737
8 October 2013 Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 4731133
17 December 2012 Spot Check (Safety)
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4503738
27 July 2012 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 4392459
27 April 2012 MTSA Verification · Industry Initiated Exam
Physical examination · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 4299001
2 November 2011 Administration
Administrative · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 4266759
24 July 2009 Administration
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3544773
2 December 2008 Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3373184
20 May 2008 Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3212111
27 March 2008 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3286072
20 December 2007 Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3119334
26 May 2006 MTSA Verification · Uninspected Other
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2659577
21 April 2006 Type not recorded
No type recorded · USCG Great Lakes District (dpb) · USCG Great Lakes District (CGD-GL) · Activity 2630472
16 September 2005 Type not recorded
No type recorded · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 2493979
27 April 2005 MTSA Verification
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2349373
8 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1961055
17 January 2002 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1607779
11 March 2000 Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 216797
18 May 1999 Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 57607
25 February 1998 Uninspected Towing Vessel
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 782652
6 July 1997 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 30846
22 March 1996 Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 89750
31 July 1995 Uninspected Towing Vessel
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1405762
30 July 1995 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 42745
23 June 1995 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 197945
23 June 1995 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 753700
19 January 1995 Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 692687
17 December 1994 Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 162662
25 October 1994 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 706821
27 August 1993 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 15457
28 March 1993 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 160286
22 March 1993 Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1147622
10 July 1992 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 481261

Deficiency record · 28

01 - Certificates & Documentation › 012 - Crew Certificates › Record of employment
Issued 19 May 2025 Resolved
Vessel could not provide evidence of enrollment in a drug and alcohol testing program.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2025
Resolved 21 May 2025
Resolution: Vessel rep provided evidence of 2025 enrollment and list of employees enrolled.
04 - Emergency Systems › N/A - No Subsystem › Low level lighting in corridors
Issued 19 May 2025 Resolved
No emergency lighting was provided in berthing areas.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2025
Resolved 21 May 2025
Resolution: Vessel rep provided pictures of flashlights installed by berthing room doors.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 May 2024 Resolved
Alcohol test strips are expried as of 2022. Provide onboard means to test crew post casualty.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2024
Resolved 21 May 2024
Resolution: New alcohol test strips are now onboard.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 8 May 2024 Resolved
Pilothouse port WTD is not fully engaging and locking properly adjust and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 May 2024
Resolved 9 May 2024
Resolution: 3RD Mate adjusted door and proved proper operation.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 May 2024 Resolved
Cover on light fixture aft main deck behind WTD is cracked and busted. Renew cover.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2024
Resolved 13 May 2024
Resolution: new fixture installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 May 2024 Resolved
Electrical cords are daisy chained for the 3D printer. Remove and provide proper outlet or cord.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2024
Resolved 13 May 2024
Resolution: printer removed.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 8 May 2024 Resolved
Vessels last record of testing machinery alarms was 2020. Alarms must be tested twice on 5 years. Provide record of testing all alarms.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2024
Resolved 21 May 2024
Resolution: Machinery alarm testing report was provided by CAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 8 May 2024 Resolved
Deadlight cover was removed from the aft maindeck WTD. Provide proper cover.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2024
Resolved 13 May 2024
Resolution: Deadlight cover installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 May 2024 Resolved
No record of annual ASP audit could be produced. Provide record of annual Audit within 7 days.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 May 2024
Resolved 13 May 2024
Resolution: ASP audit was not completed for 2022 or 2023.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 8 May 2024 Resolved
Properly adjust both WTD'S leading to the shaft alley and prove sealing by chauk test.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2024
Resolved 21 May 2024
Resolution: WTDs have been adjusted and close. PE conducted new chalk tests.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 May 2024 Resolved
Fire Detector on upper deck of engineroom is missing a knock out plug. Install proper plug.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2024
Resolved 13 May 2024
Resolution: Plugs where installed in the detectors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 May 2022 Resolved
Electrical panel on portside of bridge labeled Electronic Panel 2 has open breaker slots that must be covered.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2022
Resolved 16 May 2022
Resolution: Electrical panel open slots have been blanked off.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 May 2022 Resolved
Upper Bridge stairwell leading down power surge protector is hanging down and secured with duct tape. Properly support or remove.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2022
Resolved 25 May 2022
Resolution: Surge protector has been properly mounted.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 May 2022 Resolved
FM 200 system nitrogen bottle is is reading low pressure. Properly charge bottle.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2022
Resolved 25 May 2022
Resolution: Bottle is charged, gauge is faulted, back order. Bottle due for replacement next annual anyway. See special note to ensure bottle/gauge replacement by next annual or next usage, whichever is first.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 4 May 2022 Resolved
Portside potable water tank has a hole an is leaking into the engine room bilge. C/R to good metal.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2022
Resolved 16 May 2022
Resolution: Insert installed.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 4 May 2022 Resolved
Heat detector over the engine room switchboard is not mounted. Properly secure to the overhead.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2022
Resolved 25 May 2022
Resolution: Heat detector has been properly mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 4 May 2022 Resolved
Upper level engine room emergency lighting is out and fixtures are missing diffusers. Make repairs and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2022
Resolved 16 May 2022
Resolution: EM lighting in engine space repaired, missing diffusers replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 4 May 2022 Resolved
Steering space lighting is out and fixtures are missing diffusers make repairs or replace. Prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2022
Resolved 16 May 2022
Resolution: Steering gear space lighting has been restored.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 May 2022 Resolved
EPIRB hydrostatic release was not marked with date installed. Replace release
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2022
Resolved 16 May 2022
Resolution: Hydrostatic release device was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 May 2022 Resolved
Vessels life jackets and immersion suits where found throughout vessel with various names. Properly mark in block letters Bradshaw McKee
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2022
Resolved 25 May 2022
Resolution: Life jackets and immersion suits have been properly labeled.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 May 2022 Resolved
Industrial First Aid kit was missing splints. Provide onboard splints.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2022
Resolved 25 May 2022
Resolution: Splints were ordered.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 May 2022 Resolved
Provide lights and whistles on Type I PFD's for AB1, AB2 and cooks stateroom.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 June 2022
Resolved 25 May 2022
Resolution: Life jackets have been provided with lights and whistles.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 March 2022 Resolved
#1 SSG is out of commission and unable to provide electrical power. #2 SSG is operational and an additional stand-by package generator has been temporarily mounted on the fantail to provide electrical power in the event of an emergency. Prove proper operation of #1 SSG.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 4 May 2022
Resolution: Vendors made repair to out of commission generator, temporary generator was removed from fantail, verified during COI Inspection.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 26 May 2006 Resolved
Renew reflective tape on ring buoys IAW46CFR25.25-10
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2006
Resolved 26 May 2006
Communications › Radio Communications › EPIRB
Issued 26 May 2006 Resolved
Renew EPIRB Hydrostatic release, outdated IAW 46CFR25.26-50
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2006
Resolved 26 May 2006
Documentation › Markings/Placards › Official Number (US)
Issued 26 May 2006 Resolved
Mark the official number on an interior structural part of the hull IAW 46CFR67.121.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 May 2006
Resolved 26 May 2006
Fire Fighting › Fire Hoses › Condition
Issued 26 May 2006 Resolved
Replace missing Fire Fighting hose on the aft port main deck IAW46CFR25.30/27.301.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 May 2006
Resolved 26 May 2006
Fire Fighting › Fire Main › Pressure
Issued 26 May 2006 Resolved
Install a Fire Main discharge pressure gauge at pump discharge IAW46CFR27.301(e)(1).
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 May 2006
Resolved 26 May 2006

Recorded names · 1

SUSAN W. HANNAH (2007–2008). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.