Inspection history · 52
28 July 2026
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8449428
19 May 2025
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8139300
8 May 2024
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7908513
6 February 2024
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7862002
21 June 2023
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7720341
18 May 2023
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7691361
29 April 2022
Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 7440780
18 April 2022
Deficiency Check · COI Inspection · MTSA Verification · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7433418
11 March 2022
Examination of Repairs
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7411443
23 March 2020
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6928107
17 April 2019
Bulk Liquid Transfer Monitor
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6664491
12 March 2019
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6641129
27 June 2018
DAPI Audit · In-Service Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6469318
15 May 2018
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6415122
23 August 2017
Bulk Liquid Transfer Monitor
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6253666
4 March 2016
Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 5827074
16 September 2015
Load Line
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5720721
24 June 2015
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5163923
16 May 2014
Administration
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4860225
2 May 2014
Load Line/Change of Employment
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 4850737
8 October 2013
Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 4731133
17 December 2012
Spot Check (Safety)
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4503738
27 July 2012
Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 4392459
27 April 2012
MTSA Verification · Industry Initiated Exam
Physical examination · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 4299001
2 November 2011
Administration
Administrative · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 4266759
24 July 2009
Administration
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3544773
2 December 2008
Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3373184
20 May 2008
Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3212111
27 March 2008
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3286072
20 December 2007
Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3119334
26 May 2006
MTSA Verification · Uninspected Other
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2659577
21 April 2006
Type not recorded
No type recorded · USCG Great Lakes District (dpb) · USCG Great Lakes District (CGD-GL) · Activity 2630472
16 September 2005
Type not recorded
No type recorded · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 2493979
27 April 2005
MTSA Verification
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2349373
8 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1961055
17 January 2002
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1607779
11 March 2000
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 216797
18 May 1999
Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 57607
25 February 1998
Uninspected Towing Vessel
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 782652
6 July 1997
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 30846
22 March 1996
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 89750
31 July 1995
Uninspected Towing Vessel
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1405762
30 July 1995
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 42745
23 June 1995
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 197945
23 June 1995
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 753700
19 January 1995
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 692687
17 December 1994
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 162662
25 October 1994
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 706821
27 August 1993
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 15457
28 March 1993
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 160286
22 March 1993
Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1147622
10 July 1992
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 481261
01 - Certificates & Documentation › 012 - Crew Certificates › Record of employment
Issued 19 May 2025
Resolved
Vessel could not provide evidence of enrollment in a drug and alcohol testing program.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2025
Resolved 21 May 2025
Resolution: Vessel rep provided evidence of 2025 enrollment and list of employees enrolled.
04 - Emergency Systems › N/A - No Subsystem › Low level lighting in corridors
Issued 19 May 2025
Resolved
No emergency lighting was provided in berthing areas.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2025
Resolved 21 May 2025
Resolution: Vessel rep provided pictures of flashlights installed by berthing room doors.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 May 2024
Resolved
Alcohol test strips are expried as of 2022. Provide onboard means to test crew post casualty.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2024
Resolved 21 May 2024
Resolution: New alcohol test strips are now onboard.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 8 May 2024
Resolved
Pilothouse port WTD is not fully engaging and locking properly adjust and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 May 2024
Resolved 9 May 2024
Resolution: 3RD Mate adjusted door and proved proper operation.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 May 2024
Resolved
Cover on light fixture aft main deck behind WTD is cracked and busted. Renew cover.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2024
Resolved 13 May 2024
Resolution: new fixture installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 May 2024
Resolved
Electrical cords are daisy chained for the 3D printer. Remove and provide proper outlet or cord.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2024
Resolved 13 May 2024
Resolution: printer removed.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 8 May 2024
Resolved
Vessels last record of testing machinery alarms was 2020. Alarms must be tested twice on 5 years. Provide record of testing all alarms.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2024
Resolved 21 May 2024
Resolution: Machinery alarm testing report was provided by CAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 8 May 2024
Resolved
Deadlight cover was removed from the aft maindeck WTD. Provide proper cover.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2024
Resolved 13 May 2024
Resolution: Deadlight cover installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 May 2024
Resolved
No record of annual ASP audit could be produced. Provide record of annual Audit within 7 days.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 May 2024
Resolved 13 May 2024
Resolution: ASP audit was not completed for 2022 or 2023.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 8 May 2024
Resolved
Properly adjust both WTD'S leading to the shaft alley and prove sealing by chauk test.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2024
Resolved 21 May 2024
Resolution: WTDs have been adjusted and close. PE conducted new chalk tests.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 May 2024
Resolved
Fire Detector on upper deck of engineroom is missing a knock out plug. Install proper plug.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2024
Resolved 13 May 2024
Resolution: Plugs where installed in the detectors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 May 2022
Resolved
Electrical panel on portside of bridge labeled Electronic Panel 2 has open breaker slots that must be covered.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2022
Resolved 16 May 2022
Resolution: Electrical panel open slots have been blanked off.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 May 2022
Resolved
Upper Bridge stairwell leading down power surge protector is hanging down and secured with duct tape. Properly support or remove.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2022
Resolved 25 May 2022
Resolution: Surge protector has been properly mounted.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 May 2022
Resolved
FM 200 system nitrogen bottle is is reading low pressure. Properly charge bottle.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2022
Resolved 25 May 2022
Resolution: Bottle is charged, gauge is faulted, back order. Bottle due for replacement next annual anyway. See special note to ensure bottle/gauge replacement by next annual or next usage, whichever is first.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 4 May 2022
Resolved
Portside potable water tank has a hole an is leaking into the engine room bilge. C/R to good metal.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2022
Resolved 16 May 2022
Resolution: Insert installed.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 4 May 2022
Resolved
Heat detector over the engine room switchboard is not mounted. Properly secure to the overhead.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2022
Resolved 25 May 2022
Resolution: Heat detector has been properly mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 4 May 2022
Resolved
Upper level engine room emergency lighting is out and fixtures are missing diffusers. Make repairs and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2022
Resolved 16 May 2022
Resolution: EM lighting in engine space repaired, missing diffusers replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 4 May 2022
Resolved
Steering space lighting is out and fixtures are missing diffusers make repairs or replace. Prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2022
Resolved 16 May 2022
Resolution: Steering gear space lighting has been restored.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 May 2022
Resolved
EPIRB hydrostatic release was not marked with date installed.
Replace release
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2022
Resolved 16 May 2022
Resolution: Hydrostatic release device was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 May 2022
Resolved
Vessels life jackets and immersion suits where found throughout vessel with various names. Properly mark in block letters Bradshaw McKee
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2022
Resolved 25 May 2022
Resolution: Life jackets and immersion suits have been properly labeled.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 May 2022
Resolved
Industrial First Aid kit was missing splints. Provide onboard splints.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2022
Resolved 25 May 2022
Resolution: Splints were ordered.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 May 2022
Resolved
Provide lights and whistles on Type I PFD's for AB1, AB2 and cooks stateroom.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 June 2022
Resolved 25 May 2022
Resolution: Life jackets have been provided with lights and whistles.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 March 2022
Resolved
#1 SSG is out of commission and unable to provide electrical power. #2 SSG is operational and an additional stand-by package generator has been temporarily mounted on the fantail to provide electrical power in the event of an emergency. Prove proper operation of #1 SSG.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 4 May 2022
Resolution: Vendors made repair to out of commission generator, temporary generator was removed from fantail, verified during COI Inspection.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 26 May 2006
Resolved
Renew reflective tape on ring buoys IAW46CFR25.25-10
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2006
Resolved 26 May 2006
Communications › Radio Communications › EPIRB
Issued 26 May 2006
Resolved
Renew EPIRB Hydrostatic release, outdated IAW 46CFR25.26-50
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2006
Resolved 26 May 2006
Documentation › Markings/Placards › Official Number (US)
Issued 26 May 2006
Resolved
Mark the official number on an interior structural part of the hull IAW 46CFR67.121.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 May 2006
Resolved 26 May 2006
Fire Fighting › Fire Hoses › Condition
Issued 26 May 2006
Resolved
Replace missing Fire Fighting hose on the aft port main deck IAW46CFR25.30/27.301.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 May 2006
Resolved 26 May 2006
Fire Fighting › Fire Main › Pressure
Issued 26 May 2006
Resolved
Install a Fire Main discharge pressure gauge at pump discharge IAW46CFR27.301(e)(1).
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 May 2006
Resolved 26 May 2006