MAURY USCG vessel records
← All vessels

SHIRLEY ANN

SHIRLEY ANN is a 1956 towing vessel. The Coast Guard has recorded 26 inspections since 1993, most recently in August 2025, along with 51 deficiencies and 4 casualty investigations between 2004 and 2006.

Records from 1993 to 2025. Most recent: inspection, 28 August 2025.

Built
1956
Last inspected
28 August 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WZH3507
Flag
UNITED STATES
Maury page id
psix-72164

Inspections, by type

…with no type recorded13
Years with a record 14 calendar years (1993–2025)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)72.0 ft × 22.6 ft × 7.5 ft
Registered tonnagegross 95 / net 64
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLOCKPORT SHIPYARD, INC. · LOCKPORT, LA, UNITED STATES · built 1956
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCHEBOYGAN, MI
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 17 July 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it95 - Regulatory (Subpart C or D), Gross Ton
64 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspected as a tow unit · 6

Inspection history · 26

28 August 2025 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8219787
3 September 2024 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8004291
27 September 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7807327
8 June 2023 Administrative Inspection · In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7741351
13 July 2022 Initial Certification · Administrative Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7480102
15 September 2017 Administration
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6269125
24 March 2017 Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6110987
16 April 2014 DAPI Audit
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 4852414
15 June 2012 Industry Initiated Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 4342619
18 May 2010 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3741907
14 September 2006 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2778505
17 July 2006 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2772235
6 February 2006 Type not recorded
No type recorded · USCG Great Lakes District (dpb) · USCG Great Lakes District (CGD-GL) · Activity 2580142
7 December 2005 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2547696
5 December 2005 Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 2547029
21 November 2005 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2538325
14 November 2005 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2547400
16 August 2005 Uninspected Other
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2464951
15 August 2005 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2464066
15 August 2005 Type not recorded
No type recorded · Station Marblehead · USCG Great Lakes District (CGD-GL) · Activity 2465863
1 August 2004 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 2213752
17 November 1999 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 104416
11 September 1995 Uninspected Towing Vessel
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1380302
9 September 1995 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 10641
9 September 1995 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 12749
8 November 1993 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 131693

Deficiency record · 51

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 September 2023 Resolved
Smoke detectors need to be added to accommodation spaces/ galley.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2023
Resolved 28 November 2023
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 27 September 2023 Resolved
Flam locker on second deck is not a certified flam locker. It's a JOBOX that has been painted yellow. Replace with approved flam locker and remove excess flammables and combustibles from engine room to new locker.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2023
Resolved 28 November 2023
09 - Working and Living Conditions › 092 - Working Conditions › Winches & capstans
Issued 27 September 2023 Resolved
Vessel's towing gear needs thorough inspection and replacement of unserviceable equipment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2023
Resolved 28 November 2023
Engineering › Fuel Oil Service System › Piping
Issued 16 August 2005 Resolved
Repair all engine and generator fuel leaks.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2005
Resolved 26 August 2005
Communications › Radio Communications › VHF Radiotelephone
Issued 16 August 2005 Resolved
Provide proof that the vessel's radios are inspected under the Great Lakes Agreement as per 47CFR80.953.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2005
Resolved 26 August 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 16 August 2005 Resolved
Repair or remove broken exposed light fixture, located on the flying bridge.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2005
Resolved 26 August 2005
Stability › Watertight Integrity › General
Issued 16 August 2005 Resolved
Prove proper operation and water tight integrity of all main deck WTD's.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2005
Resolved 26 August 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 August 2005 Resolved
Install guards on all exposed rotating machinery belts and pulleys.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2005
Resolved 26 August 2005
Electrical › Electrical Distribution System (service) › Cable
Issued 16 August 2005 Resolved
Remove or replace all non-marine grade electrical wire.
Condition: Improper Installation
Due 25 October 2005
Resolved 18 November 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 16 August 2005 Resolved
Properly mount (install approved brackets) to engineroom fire extinguishers
Due 25 October 2005
Resolved 18 November 2005
Documentation › Logs/Records › Declaration of Inspection
Issued 16 August 2005 Resolved
Ensure vessel maintains copies of all oil transfer Declarations of Inspection as per 33 CFR 156.150
Due 25 October 2005
Resolved 18 November 2005
Documentation › Logs/Records › Declaration of Inspection
Issued 16 August 2005 Resolved
Ensure vessel maintains copies of all oil transfer Declarations of Inspection as per 33 CFR 156.150
Due 25 October 2005
Resolved 26 August 2005
Operations/Management › Navigation Safety › Arrival/Departure Tests
Issued 16 August 2005 Resolved
Ensure all navigational tests and inspections are conducted and logged as per 33 CFR 164.80
Due 25 October 2005
Resolved 18 November 2005
Electrical › Electrical Distribution System (service) › Junction Box
Issued 16 August 2005 Resolved
Ensure all dead end electrical wires are removed or terminated in weather-tight junction boxes.
Due 25 October 2005
Resolved 18 November 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 August 2005 Resolved
Ensure all wire nut, twisted wires are taped and installed in weather-tight junction boxes or are replaced with a positive crimp connector.
Due 25 October 2005
Resolved 18 November 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 August 2005 Resolved
Ensure all wires are supported with metal clamps every 24" or are installed in wire runs.
Due 25 October 2005
Resolved 18 November 2005
Engineering › Sea-water System (primary cooling) › Piping
Issued 16 August 2005 Resolved
Ensure all piping systems are properly supported with metal hangers.
Due 25 October 2005
Resolved 18 November 2005
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 16 August 2005 Resolved
Ensure all open electrical boxes and controllers are covered or blanked off.
Due 25 October 2005
Resolved 18 November 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 16 August 2005 Resolved
Ensure all deck and machinery space lights with glass globes are properly guarded or caged.
Due 25 October 2005
Resolved 18 November 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 16 August 2005 Resolved
Remove engineroom non-marine grade lights and ensure all electrical wires are marine grade.
Due 25 October 2005
Resolved 18 November 2005
Construction/Loadline › Structures › End Bulkhead
Issued 16 August 2005 Resolved
Repair hole in the starboard side aft engineroom entrance bulkhead.
Due 25 October 2005
Resolved 18 November 2005
Engineering › Fuel Oil Service System › Filter
Issued 16 August 2005 Resolved
Install metal heat shields on all Racor fuel filters.
Due 25 October 2005
Resolved 5 December 2005
Electrical › Electrical Distribution System (service) › Switchboard
Issued 16 August 2005 Resolved
Install rubber mats in front of the engineroom switchboards.
Due 25 October 2005
Resolved 18 November 2005
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 16 August 2005 Resolved
Properly blanket MDE exhaust flanges.
Due 25 October 2005
Resolved 18 November 2005
Electrical › Electric Supply System (service) › Battery Installation
Issued 16 August 2005 Resolved
Cover all exposed battery terminals.
Due 25 October 2005
Resolved 18 November 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 16 August 2005 Resolved
Cover exposed engine room flourescent lights.
Due 25 October 2005
Resolved 18 November 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 16 August 2005 Resolved
Repair or remove bare light socket in engine room on the port side of the ladder.
Due 25 October 2005
Resolved 26 August 2005
Stability › Weathertight Integrity › General
Issued 16 August 2005 Resolved
Repair the broken port light window strb side, aft, engine room.
Due 25 October 2005
Resolved 5 December 2005
Accommodation/Occupational Safety › Ventilation › General
Issued 16 August 2005 Resolved
Make the engineroom overhead , which leads to the berthing space, vapor tight to prevent the spread of carbon monoxide.
Due 25 October 2005
Resolved 18 November 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 16 August 2005 Resolved
Properly repair the light assembly on the bridge, the globe light is broken and there is a hanging socket inside the globe.
Due 25 October 2005
Resolved 18 November 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 August 2005 Resolved
Ensure all operating station console gauges function properly.
Due 25 October 2005
Resolved 5 December 2005
Engineering › Generator (propulsion-electric) › Charger
Issued 16 August 2005 Resolved
Replace both MDE's alternator belts.
Due 25 October 2005
Resolved 26 August 2005
Construction/Loadline › Penetrations › Valve Flange
Issued 16 August 2005 Resolved
Cap or remove the through-hull valve (1.5") on the bulkhead behind teh hydraulic tank going overboard.
Due 25 October 2005
Resolved 26 August 2005
Stability › Watertight Integrity › General
Issued 16 August 2005 Resolved
Ensure proper operation of the upper most dog on the aft, upper, engineroom WTD, which leads to the winch enclosure area. Once repairs are complete, prove proper operation of the door via a chalk test.
Condition: Improper/Lack of Maintenance
Due 25 October 2005
Resolved 18 November 2005
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 12 August 2005 Resolved
Vessel's original Certificate of Documentation not onboard. (46 CFR 67.7)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2005
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 12 August 2005 Resolved
Vessel transfer procedures do not meet regulatory requirements. (46 CFR 155.750)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2005
Documentation › Logs/Records › MIS Form
Issued 12 August 2005 Resolved
Company unable to provide annual drug testing (MIS) report. (46 CFR 16.500)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2005
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 12 August 2005 Resolved
Vessel's depth sounding device not operable. (33 CFR 164.72(a)(5))
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2005
Fire Fighting › Fire Hoses › Condition
Issued 12 August 2005 Resolved
Replace leaky fire hoses. (46 CFR 27.301)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2005
Fire Fighting › Fire Pumps › Arrangement
Issued 12 August 2005 Resolved
Install control to energize fire pump from operating station or install approved portable fire pump. (46 CFR 27.301)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2005
Fire Fighting › Semiportable CO2 Fire Extinguishers › Location
Issued 12 August 2005 Resolved
Properly install (mount) semi-portable B-V fire extinguisher.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2005
Resolved 26 August 2005
Fire Fighting › Remote Fuel Shutoff › General
Issued 12 August 2005 Resolved
Install remote fuel shut-offs in engine room. (46 CFR 27.201)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2005
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 12 August 2005 Resolved
Fire detectin system is inoperable. Repair & provide Professional Engineer certification of system. (46 CFR 27.203)
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2005
Resolved 26 August 2005
Personnel › Training › Fire Fighting Basic
Issued 12 August 2005 Resolved
Prove crew participation in firefighting training and drills.
Due 25 October 2005
Resolved 18 November 2005
Communications › Visual Communication › Red Warning Signal
Issued 12 August 2005 Resolved
Install general alarm red strobe light and placard in engine room. (46 CFR 27.201)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2005
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 12 August 2005 Resolved
Install personal water lights on each Type I PFD. (46 CFR 25.25-15)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2005
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 12 August 2005 Resolved
Label all Type I PFD's with vessel Name. (46 CFR 25.25-11)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2005
Communications › Radio Communications › EPIRB
Issued 12 August 2005 Resolved
Install approved 406 MHz EPIRB
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2005
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 12 August 2005 Resolved
Install approved closure device for MSD overboard discharge line. (46 CFR 159.7)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2005
Lifesaving
Issued 11 September 1995 Resolved
PROVIDE LIGHTS AND MARKINGS ON EXPOSURE SUITS.
Condition: Unknown
Due 21 September 1995
Resolved 19 September 1995
Documentation
Issued 11 September 1995 Resolved
PROVIDE A OIL DISCHARGE PLACARD AND A GARBAGE PLACARD.
Condition: Unknown
Due 21 September 1995
Resolved 19 September 1995

Casualty record · 4

1 August 2004Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 2213752
15 August 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 2464066
14 November 2005Routine · role: Involved in a Marine Casualty · activity 2547400
17 July 2006Routine · role: Involved in a Marine Casualty · activity 2772235
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

KURT R. LUEDTKE (2004–2006). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.