MAURY USCG vessel records
← All vessels

OSG 350

Built
2010
Last inspected
1 June 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 1 June 2026
…with no type recorded12
Operational controls None recorded without a removal date
Years with a record 17 calendar years (2010–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1026033
Flag
UNITED STATES
Tonnage
27615 - Regulatory (Subpart C or D), Gross Ton 27439 - Convention (Subpart B), Gross Ton 27615 - Regulatory (Subpart C or D), Net Ton 17161 - Convention (Subpart B), Net Ton 57167 - Dead Weight, Ton
Maury page id
psix-1026033
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

Inspection history · 54

1 June 2026 Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8385830
14 July 2025 Periodic Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8185845
30 March 2025 In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8101970
23 October 2024 Drydock Exam · Cargo Tank Internal · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8024372
31 July 2024 MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7971666
6 July 2024 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7950517
1 June 2024 Damage Survey · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7924760
16 June 2023 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7716671
2 May 2023 Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7662417
28 December 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7614082
3 May 2022 MARPOL Annex V Examination · MARPOL Annex I Examination · MTSA Verification · Administrative Inspection · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7443627
17 June 2021 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7228307
17 December 2020 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7141865
6 August 2020 Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7025801
23 July 2020 Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7032188
18 May 2020 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 6956706
29 April 2020 Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6945723
28 April 2020 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6949287
20 February 2020 MTSA/ISPS Verification · COI Inspection · MARPOL Annex V Examination · MARPOL Annex I Examination · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6912570
3 June 2019 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6702449
31 January 2019 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6619576
31 January 2019 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6620851
8 June 2018 Administrative Inspection · Periodic Inspection · Deficiency Check · MTSA/ISPS Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6438208
22 March 2018 Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6378851
17 May 2017 Annual Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6148152
10 June 2016 Annual Inspection · MTSA Verification · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5903000
16 March 2016 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5835866
17 February 2015 Drydock Exam · Internal Structural Exam · COI Inspection · Cargo Tank Internal
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5070113
12 January 2015 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5052382
10 December 2014 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5041121
6 August 2014 Damage Survey · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4945803
22 April 2014 Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4842637
16 April 2014 Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4838131
9 January 2014 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4786169
7 November 2013 Examination of Repairs · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4833107
30 June 2013 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4638732
5 June 2012 MTSA Verification · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4334790
30 May 2012 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4333384
11 April 2012 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4285069
23 March 2012 Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4270218
23 March 2012 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4271453
8 July 2011 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4074363
5 July 2011 Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4071171
18 June 2011 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4073789
14 June 2011 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4044523
16 November 2010 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3894044
30 September 2010 Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3860512
20 September 2010 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3854191
25 June 2010 Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3776252
17 June 2010 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3769797
14 May 2010 Examination of Repairs · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3738265
28 April 2010 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3725960
5 April 2010 Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3709186
27 March 2010 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3707060

Deficiency record · 28

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 14 July 2025 Resolved
#6 Stbd Cargo Tank (SCT) Hi Level Alarm was found inoperative. Prove proper operation of the #6 SCT Hi Level Alarm within 14 days prior to carrying cargo in #6 SCT. Until proper operation of the Hi Level Alarm is restored the vessel may load cargo in the #6 SCT provided that the tank gauging is constantly monitored by a tankerman. CITE: 33 CFR 155.480(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2025
Resolved 15 July 2025
Resolution: Technician report.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 July 2025 Resolved
The Port Navigation Light was inoperative. Within 14 days make permanent repair to the port navigation light. Prior to satisfactorily repairing the port navigation light, the vessel is to use its portable port navigation light. CITE: 33 CFR 83.24(c)(ii)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2025
Resolved 15 July 2025
Resolution: Port captain attestation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 June 2024 Resolved
46CFR111.01-1(a) Electrical installations on vessels must ensure: Maintenance of services necessary for safety under normal and emergency conditions. Protection of passengers, crew, other persons, and the vessel from electrical hazards. Maintenance of system integrity through compliance with applicable system requirements (IEEE, NEC, IEC, Etc) Vsl reported catastrophic failure of #2 cargo/ballast generator due to winding malfunction. #1 and #3 cargo/ballast generators inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2024
Resolved 31 July 2024
Resolution: Vessel has completed repairs of #1 and #3 generators. With these generators operational, vessel is able to conduct cargo operations. #2 Gen is being repaired (windings) and follow up will be conducted by ABS.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 June 2023 Resolved
Each fire extinguisher shall be marked with a number and the location where stowed shall be marked in corresponding numbers in at least 1/2 inch figures. Vessel needs to properly label extinguishers and location to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2023
Resolved 26 June 2023
Resolution: Deficiency cleared to the satisfaction of Marine Inspector. See ABS Class report: 5914247
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 June 2023 Resolved
In a cargo vessel, neither the failure of such a gauge nor an overfilling of the tank may permit release of fuel into the space. The use of cylindrical gauge-glasses is prohibited. The use of oil-level gauges with flat glasses and self-closing valves between the gauges and fuel tanks is acceptable. Valves were inoperable at the top and bottom of the sight glass. Repair or replace to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2023
Resolved 26 June 2023
Resolution: Deficiency cleared to the satisfaction of Marine Inspector. See ABS Class report: 5914247
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 June 2023 Resolved
Each lifebuoy must be capable of being rapidly cast loose. Lifebuoy was tied to the handrail.
Action required: 10 - Deficiency Rectified
Due 16 June 2023
Resolved 16 June 2023
Resolution: Crew untied Lifebuoy.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Gas instruments
Issued 16 June 2023 Resolved
Manned tank barges and tank ships authorized to carry Grade A, B, C, or D liquids at any temperature, or Grade E liquids at elevated temperatures, shall be provided with a combustible gas indicator suitable for determining the presence of explosive concentrations of the cargo carried. Portable gas calibration system was inoperable. Provide evidence of a calibrated portable gas meter to the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2023
Resolved 26 June 2023
Resolution: Deficiency cleared to the satisfaction of Marine Inspector. See ABS Class report: 5914247
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 11 May 2022 Resolved
(3) Before each cargo tank is crude oil washed, the oxygen content in that tank is 8 percent or less by volume at the locations under paragraph (a)(1) of this section. While witnessing IG System test MI found IGS leaking regular ambient air disabling safety. Repair to satisfaction of Class and send Tech and Class report to attending MI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2022
Resolution: RO report revcd and up loaded in vessel document tab, def cleared.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 11 May 2022 Resolved
(d) Items of equipment, which are in use on vessels, previously approved by the Commandant but not complying with the latest specification requirements may be continued in use so long as they are maintained in good and serviceable condition to the satisfaction of the Officer in Charge, Marine Inspection, until replacement is deemed necessary by such officer or as specified in the regulations. MI found numerous sensors faults in the Gas detection system. Repair faults and calibrate to satisfaction of Class and send Tech and Class report to attending MI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2022
Resolution: RO report revcd and up loaded in vessel document tab, def cleared.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 11 May 2022 Resolved
Thermal fluid heaters are examined by a marine inspector at the inspection for certification, periodic inspection and when directed by the Officer in Charge Marine Inspection, to determine that the complete unit is in a safe and satisfactory condition. The visual examination includes, but is not limited to, the combustion chamber, heat exchanger, refractory, exhaust stack, and associated pumps and piping. MI found TFH leaking. Repair to satisfaction of Class and send Tech and Class report to attending MI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2022
Resolution: RO report revcd and up loaded in vessel document tab, def cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 April 2020 Resolved
Actuator valve in ballast #5 std had loss of hydraulic fluid and can only be used manually. Valve actuators must be capable of closing the valves under all conditions except during physical interruption of the power system.
Action required: 10 - Deficiency Rectified
Due 6 May 2020
Resolved 1 May 2020
Resolution: Replaced actuator valve.
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Condition
Issued 17 May 2017 Resolved
The Nitrogen cylinder for the semi-portable fire extinguisher located on the aft cargo deck is in poor condition, the cylinder neck and bottom are severely corroded. Replace cylinder or provide a condition report from an authorized servicing company.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 24 May 2017
Resolution: Received servicing report indicating the N2 cylinder was renewed.
Deck/Cargo › Ballast › Piping
Issued 6 August 2014 Resolved
Vessel experienced a Hydraulic leak in the No. 1S WBT suction valve causing Hydraulic oil to leak into the 2S WBT. Vessel is to submit a plan to remove ballast water from 2S tank and how vessel will conduct cargo ops prior making permanent repairs. Vessel to affect repairs to 1S WBT Suction val and carry out testing to the satisfaction of USCG Marine Inspector.
Condition: Design Flaw
Due 26 August 2014
Resolved 29 August 2014
Resolution: Witnessed operation of the valve and verified no hydraulic leaks.
Engineering › Compressed Air System (control) › Valve
Issued 22 April 2014 Resolved
Prior to operation, prove proper operation of relief valve on air reciever #186544.
Action required: 705 - Other - as specified
Due 30 April 2014
Resolved 23 April 2014
Resolution: Chief engineer replaced relief valve on air reciever. Tested sat.
Electrical › Electric Generation Source (service) › Generator
Issued 22 April 2014 Resolved
Prior to operation, prove proper operation of remote shutdown on generator #1.
Action required: 705 - Other - as specified
Due 30 April 2014
Resolved 23 April 2014
Resolution: Generator #1 remote shutdown repaired and tested satisfactorily.
Deck/Cargo › Inert Gas System › IGS Scrubber
Issued 9 January 2014 Resolved
Prior to using IG system, provide technician's report stating the cause of the issue and any and all repairs made to the system.
Action required: 705 - Other - as specified
Resolved 15 January 2014
Resolution: IG system operating correctly. Issue was due to excessive cold.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 7 November 2013 Resolved
Submit repair proposal and make permanent repairs to leak on #4 cargo pump stripping line prior to transfer of cargo through #1 cargo system.
Action required: 705 - Other - as specified
Resolved 13 November 2013
Resolution: Vessel hydrostatically tested the repair while performing their annual cargo line testing. No leaks noted.
Documentation › Markings/Placards › Warning Signs
Issued 5 June 2012 Resolved
Re-stencil benzene warning signs located at miship.
Action required: 705 - Other - as specified
Due 19 June 2012
Resolved 6 June 2012
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 5 June 2012 Resolved
Mark vapor hoses with red/yellow colors.
Action required: 705 - Other - as specified
Due 19 June 2012
Resolved 6 June 2012
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 June 2012 Resolved
Make fwd port life ring light operational.
Action required: 705 - Other - as specified
Due 19 June 2012
Resolved 6 June 2012
Lifesaving › Lifebuoys › Serviceable
Issued 5 June 2012 Resolved
Restore fwd port life ring IAW manufacturer's instructions. Life ring plug is wasted.
Action required: 705 - Other - as specified
Due 19 June 2012
Resolved 6 June 2012
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 23 March 2012 Resolved
Prior to operating the #1 cargo pump, prove proper operation to the satisfaction of the attending marine inspector and provide service report for repairs.
Due 13 April 2012
Resolved 11 April 2012
Resolution: MI witnessed proper operation of #1 cargo pump, all sat.
Engineering › Thrusters › Blade
Issued 8 July 2011 Resolved
Bow thruster prohibited from use until permanant repairs completed.
Action required: 705 - Other - as specified
Resolved 18 March 2015
Resolution: Vessel removed and blanked off bow thruster hull penetration IAW approved ABS and MSC plans
Engineering › Thrusters › Shaft
Issued 5 July 2011 Resolved
Provide update on repair proposal following receipt of manufacturer recommendations (bow thruster).
Action required: 705 - Other - as specified
Resolved 18 March 2015
Resolution: Vessel removed and blanked the bow thruster hull penetration IAW apporved ABS and MSC plans.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 14 June 2011 Resolved
Windlass gear box cover broke prior to annual inspection. Vessel still has operable stbd anchor and emergency towing arrangement. Anchor windlass to be tested prior to being placed back into service.
Action required: 705 - Other - as specified
Resolved 15 August 2011
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 30 September 2010 Resolved
Repair cargo system "A" to ensure system can be safely operated without leaks. Cargo system "A" (Topside) is prohibited from use until repairs made and system tested by attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 November 2010
Resolution: CG-835 was cleared on board by [name withheld] on 03Nov2010, but not in MISLE. Additionally, original activity where the 835 was opened has been closed and a new activity was never opened.
Engineering › Bilge Water Management System › Piping
Issued 17 June 2010 Resolved
Prove proper operation of #5 Stbd ballast tank valve and associated hydraulic line prior to conducting ballasting operations from affected tank to the satisfaction of attending Marine Inspector.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 23 June 2010
Resolved 20 September 2010
Resolution: SAT operation of valve and examined cleanliness of tank.
Engineering › Thrusters › Seal
Issued 28 April 2010 Resolved
Bowthruster was leaking oil into the environment. Vessel's bowthruster is to remain secured until permanent repairs are made to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 May 2010
Resolution: Permanent repairs made to bow thruster and vessel completed satisfactory operational tests.

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.

Maury does not score, rate, or grade vessels. What Maury does not do · Glossary · Correct a record.