Inspection history · 55
11 May 2026
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 8356438
21 October 2025
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8256272
20 June 2025
Deficiency Check · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8163193
20 June 2025
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8165561
25 April 2025
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8120129
30 September 2024
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8012106
18 July 2024
Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7961432
12 February 2024
In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7864631
22 November 2023
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7831439
2 May 2023
Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7679208
12 September 2022
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7540353
24 January 2022
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7385226
17 September 2021
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7314568
18 June 2021
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7261159
20 September 2020
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7062921
4 August 2020
Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7024320
4 August 2020
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7058035
13 July 2020
Administrative Inspection · Initial Certification
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6973769
19 April 2018
Industry Initiated Exam · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6399856
13 February 2018
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6355781
11 January 2018
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6347346
6 November 2017
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6301579
22 July 2017
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6219499
5 May 2016
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5869913
21 April 2016
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5870796
18 March 2016
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5836281
27 May 2015
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5137495
21 May 2015
Deficiency Check · Risk-based Targeted Exam
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5131533
20 May 2015
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5131132
23 April 2015
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5138776
21 April 2015
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5138880
31 December 2014
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5048726
12 December 2013
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4777229
22 September 2013
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4727399
25 June 2012
Deficiency Check · Industry Initiated Exam
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4356651
12 January 2010
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3663372
14 November 2008
Type not recorded
No type recorded · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 3364814
15 May 2008
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3233988
19 February 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2874197
10 October 2005
Type not recorded
No type recorded · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 2512737
15 August 2005
Type not recorded
No type recorded · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2543382
19 July 2004
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2138626
13 May 2003
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1793252
3 September 2002
Uninspected Towing Vessel
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1672935
25 November 2000
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 164025
14 August 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 719070
24 July 1997
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 758720
22 July 1997
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 207193
16 July 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 429
24 January 1997
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 92880
16 July 1996
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 719071
21 June 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 141050
21 June 1996
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 156223
23 March 1996
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 37605
9 January 1996
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 60434
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 21 June 2025
Resolved
Towing vessels must be equipped with the following equipment, as applicable to the area of operation: Search light, controllable from the vessel's operating station and capable of illuminating objects at a distance of at least two times the length of the tow. Searchlights were damaged in bridge allision. Install searchlight to the satisfaction of the attending marine inspector.
****VESSEL IS RESTRICTED TO DAYTIME (SUNRISE TO SUNSET) AND FAIR WEATHER OPERATIONS ONLY****
This allowance ends at sunset on 23JUN2025 at which point a searchlight must be installed to continue operations and clear deficiency.
Cite: 46 CFR 140.725(b)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 22 June 2025
Resolution: MI observed the searchlight to be fully repaired and operational.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 20 June 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessel self-reported an allision with the Popps Ferry Bridge in Biloxi, MS, severely compromising all navigational equipment on the mast. Vessel is currently moored at the Fuel and Ice Dock in Biloxi, MS. Prior to any movement contact Sector Mobile for authorization. Conduct repairs to the satisfaction of the Coast Guard marine inspector.
Cite: 46 CFR 143.205(a)
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 June 2025
Resolution: Vessel repaired all navigational equipment to the satisfaction of the MI with the exception of the searchlight.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 July 2024
Resolved
At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light. Water light on one lifebuoy was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 July 2024
Resolved 19 July 2024
Resolution: New batteries were installed.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 18 July 2024
Resolved
A towing vessel must carry a combination of day and night visual distress signals indicated in Table 141.370 for specified areas where the vessel operates. Vessel was required 3 day and 3 night flares. Vessel had a total of 4 flares under approval series 160.121.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2024
Resolved 1 August 2024
Resolution: Vessel purchased additional flares to meet requirements
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 July 2024
Resolved
Flammable and combustible products must not be stored in machinery spaces, unless they are stored in a suitable container. Engine room had several full 5 gallon pails of unused oil as well as paint cans.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2024
Resolved 1 August 2024
Resolution: Vessel crew removed flammable and combustible products from machinery spaces.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 July 2024
Resolved
Nonconductive mats or grating must be provided on the deck in front of each switchboard. Several breaker panels had no mats or grating.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2024
Resolved 1 August 2024
Resolution: Vessel crew installed rubber matting in required places.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 March 2024
Resolved
All portable fire extinguishers, semi-portable fire-extinguishing systems, and fixed fire-extinguishing systems required by this part must be approved by the Commandant (CG–ENG). Approval is valid only with approved bracket. Fire extinguisher located in forward hold was not mounted.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 March 2024
Resolution: Fire extinghuisher properly mounted in approved bracket.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 March 2024
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space. Pumps, one located at forward end of each main diesel engine, leaks lubricating oil onto hoses directly below the pumps; hydraulic steering system directional valves (located vertically on aft bulkhead in engine room) leaks hydraulic oil, and the port main diesel engine fuel supply line leaked fuel oil in vicinity of valve approximately a foot above deck plate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2024
Resolved 1 April 2024
Resolution: Identified leaks (oil, hydraulic, and fuel) secured and equipment in vicinity of each leak cleaned of all oily residues.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 15 March 2024
Resolved
No Certificate of Documentation issued under this part will be deemed valid for operation of the vessel until the vessel is marked in accordance with this subpart. Vessel not marked with vessel's name or hailing port.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2024
Resolved 6 May 2024
Resolution: Vessel operator properly marked vessel with name on stern and bow; and hailing port on stern.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 March 2024
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.
- Electrical distribution located on aft bulkhead of upper engine room missing blank
- electrical junction box located on forward bulkhead of electronics room (below wheel house) had loose cover (Corrected)
-Battery Boxes in electrical room (below wheel house) not secured to deck (Corrected)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 April 2024
Resolution: Blank installed in junction box.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 March 2024
Resolved
Engine room to be fitted with one 40-B portable fire extinguisher for each 1,000 brake horsepower of the main engines or fraction thereof. Engine room had only 3 portable fire extinguishers meeting at least the 40-B rating. (Requirement also listed on COI.)(CORRECTED)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 March 2024
Resolution: Approved and properly rated portable fire extinguisher relocated to the vessel's engine room.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 15 March 2024
Resolved
Each remote valve control must be marked in clearly legible letters, at least 25 millimeters (1 inch) high, indicating the purpose of the valve and the way to operate it. Labels (2, one on each side of vessel) did not include sufficient purpose as crew was unable to identify whether or not activation secured all fuel or only fuel to specific machinery.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2024
Resolved 24 April 2024
Resolution: New placards adequately detail purpose and instructions to operate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 March 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Fuel hose between #1 starboard fuel tank and fuel manifold severely kinked.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2024
Resolved 1 April 2024
Resolution: Fuel hose re-aligned to eliminate hose distortion.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 2 May 2023
Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. First aid kits were expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 5 June 2023
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 2 May 2023
Resolved
Each remote valve control must be marked in clearly legible letters, at least 25 millimeters (1 inch) high, indicating the purpose of the valve and the way to operate it. Contrasting lettering was faded off.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 10 July 2023
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 2 May 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Light covers missing or broken in the Mate's Bunkroom.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2023
Resolved 5 June 2023
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 2 May 2023
Resolved
A fixed fire pump must be capable of: (1) Delivering water simultaneously from the two highest hydrants, or from both branches of the fitting if the highest hydrant has a Siamese fitting, at a pitot-tube pressure of at least 344(kPa) (50 pounds per square inch (psi)), and a flow rate of at least 300 liters per minute (lpm) (80 gallons per minute (gpm). Vessels fixed fire pump was unable to provide sufficient flow. portable fire pump placed on board until repairs could be made to the satisfaction of local Marine Inspector.
Action required: 705 - Other - as specified
Resolved 10 July 2023
Resolution: fixed pump will be repaired at the 5 year dry dock.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 12 September 2022
Resolved
Each towing vessel must have either a self-priming, power-driven, fixed fire pump with 50 psi from the two highest hydrants, or a portable pump with 60 psi. Vessel's fixed pump unable to deliver sufficient pressure through two hoses; vessel not equipped with a fully outfitted portable fire pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 September 2022
Resolution: Properly operating portable fire pump satisfying regulatory requirement placed on board vessel.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 September 2022
Resolved
Portable and semi-portable fire extinguishers must be inspected, maintained, and tested in accordance with the inspection, maintenance procedures, and hydrostatic pressure tests required by Chapters 7 and 8 of NFPA 10, Standard for Portable Fire Extinguishers, (ii) Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Monthly checks not performed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 September 2022
Resolution: Chief engineer provided report showing fire extinguishers had been checked and TVR updated (via tag on each extinguisher).
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 September 2022
Resolved
The whistle, bell and gong shall comply with the specifications in Annex III to these Rules (33 CFR part 86); Sound signal intensity and range of audibility require minimum for vessel length, 1 nautical mile. Vessel's wistle unable to meet required range.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2022
Resolved 22 September 2022
Resolution: Chief engineer proved proper operation of vessel's whistle.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 September 2022
Resolved
Each lifebuoy with a floating electric water light must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the water light around the body of the lifebuoy. Lifebuoy's water light lanyard on port side of pilot house was less than 3 feet in length.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2022
Resolved 22 September 2022
Resolution: Lifebuoy's water light lanyard on port side of pilot house was properly sized.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 September 2022
Resolved
The sidelights of vessels of 20 meters or more in length shall be fitted with matt black inboard screens. A portion of the starboard sidelight screen had been painted white.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2022
Resolved 22 September 2022
Resolution: The starboard sidelight screen had been re-painted the correct color.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 12 September 2022
Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. Superstructure bulkhead located on starboard side and just below the pilot house had 2 small holes which were not fitted with closure devices.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2022
Resolved 13 September 2022
Resolution: Holes appropriately fitted with closure devices.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 January 2022
Resolved
The Certificate of Financial Responsibility (COFR) Operator must apply for and ensure the vessel is covered at all times by a current COFR. IAW 33 CFR 138.170(b) During a period of non-compliance with COFR certificate requirements, ALL USE by the vessel of the navigable waters of the United States, of any port or other place subject to the jurisdiction of the United States is forbidden. In addition, IAW 33 CFR 138.170(e) any vessel subject to this COFR requirements which is found in the navigable waters without a COFR, or for which the necessary evidence of financial responsibility has not been established and maintained as required, is subject to seizure by, and forfeiture to, the United States. IAW 33 138.170(d) vessel is detained until the vessel is compliant with COFR requirements. COFR Currently Revoked.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 September 2022
Resolution: NFPC report states new and valid COFR issued to vessel on 02 Sep 2022.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 September 2021
Resolved
Flammable liquid storage cabinets on 2nd deck do not meet specifications in stated cite and are constructed of aluminum. Replace storage cabinets with cabinets meeting specifications by next credit dry dock (due no later than July 13, 2025).
Action required: 705 - Other - as specified
Due 13 July 2025
Resolved 11 May 2026
Resolution: The flame locker was replaced with a proper locker.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 September 2021
Resolved
The frame or support of the engine room semi-portable fire extinguisher must be welded or otherwise permanently attached to a steel bulkhead or deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2021
Resolved 22 October 2021
Resolution: Received photographic evidence via email sufficient to clear def.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 4 August 2020
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford protections against hazards to life, property, and environment. Vessel was involved in a marine casualty, grounding, and sustained damage do the hull. Vessel has hole in PORT generator room where water is ingressing. Make temporary repairs to hole/hull to the satisfaction of the marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 August 2020
Resolution: Inspected repairs and witnessed satisfactory testing.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 4 August 2020
Resolved
Survey damage, provide repair proposal, make permanent repairs to the satisfaction of the attending Coast Guard marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 August 2020
Resolution: Inspected repairs and witnessed satisfactory testing.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 July 2020
Resolved
Vessel must ensure flame bowls are properly installed on RACOR filters.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 23 August 2020
Resolution: Vessel installed flame bowls.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 13 July 2020
Resolved
Vessel must have a 40-B fire extinguisher at the flammable materials storage cabinets.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 23 August 2020
Resolution: Vessel has installed a 40-B at the Flam Locker
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 13 July 2020
Resolved
All exits must be marked with phosporescent indiators to facilitate egress.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 23 August 2020
Resolution: Vessel installed proper markings.
Operations/Management › Navigation Safety
Issued 3 September 2002
Resolved
No log of required tests IAW 33 CFR 164.78 (b) LEGACY COMPONENT DESC: Towing Tests/Inspections
Due 3 October 2002
Resolved 4 September 2002
Resolution: Stamp log book with required tests
Operations/Management › Drug and Alcohol Testing
Issued 3 September 2002
Resolved
EAP information not posted LEGACY COMPONENT DESC: EAP Display Requirements
Due 3 October 2002
Resolved 4 September 2002
Resolution: Posted hotline information
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 3 September 2002
Resolved
Nav Rules outdated
Due 3 October 2002
Resolved 4 September 2002
Resolution: Purchased updated Nav Rules
Communications › Alarms/Indicators
Issued 3 September 2002
Resolved
Fire detection system not installed IAW 46 CFR 27.210 LEGACY COMPONENT DESC: Fire Alarm
Action required: 17 - Rectify deficiencies prior to departure
Due 15 September 2002
Resolved 4 September 2002
Resolution: Fire detection system installed IAW 46CFR27.210
Pollution Prevention/Response › Prevention Equipment
Issued 3 September 2002
Resolved
MSD missing placard LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Due 3 October 2002
Resolved 4 September 2002
Resolution: Posted required information
Communications › Alarms/Indicators › General Alarm
Issued 3 September 2002
Resolved
General Alarm missing sign IAW 46 CFR 27.205 (a)(3)
Due 3 October 2002
Resolved 4 September 2002
Resolution: Posted required sign
Documentation › Markings/Placards
Issued 3 September 2002
Resolved
MARPOL sticker missing LEGACY COMPONENT DESC: Garbage Placard
Due 3 October 2002
Resolved 4 September 2002
Resolution: Posted required information