Records from 1995 to 2026. Most recent: inspection, 12 June 2026.
Documentation record
Registered dimensions (L × B × D)166.6 ft × 36.0 ft × 7.7 ft
Registered tonnagegross 549 / net 388
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDRAVO CORPORATION · PITTSBURGH PA, UNITED STATES · built 1941
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPADUCAH, KY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 July 2026 · expires 31 August 2027
Service, as the file records itTowing Vessel
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it549 - Regulatory (Subpart C or D), Gross Ton
388 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 34
12 June 2026
Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8403120
10 August 2025
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8212873
21 September 2022
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7570722
17 February 2022
Initial Certification · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7449000
23 February 2021
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7145026
28 March 2019
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6651547
2 May 2018
Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6414397
17 September 2017
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6274684
5 December 2016
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6052583
12 September 2016
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6028834
10 January 2016
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5795144
18 November 2015
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5768720
22 September 2015
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5726063
12 February 2014
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4799605
22 March 2013
Deficiency Check · Risk-based Targeted Exam · DAPI Audit
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4557172
21 October 2008
Type not recorded
No type recorded · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 3348788
15 May 2008
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3233988
7 October 2006
Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2797807
4 October 2006
Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2793363
1 October 2006
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2794476
23 August 2006
Type not recorded
No type recorded · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2773064
19 April 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2628311
7 October 2005
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2513871
24 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1979594
12 October 1999
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 433948
21 August 1999
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 433851
22 July 1998
Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 175622
2 May 1998
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 166403
9 October 1997
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 145284
5 September 1997
Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 97565
28 May 1997
Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 404185
18 November 1995
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 17442
15 May 1995
Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 73870
13 May 1995
Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 130944
Engineering
Issued 21 August 1999
Resolved
Personel have to purge the water from the fuel tanks into some sort of contained to be properly disposed of. The practice of draining directly into the bilge must stop.
Condition: Unknown
Due 21 September 1999
Resolved 18 October 1999
Accommodation/Occupational Safety
Issued 21 August 1999
Resolved
Air conditioning units were missing the proper protective cover.
Condition: Unknown
Due 21 September 1999
Resolved 18 October 1999
Electrical
Issued 21 August 1999
Resolved
Search lights on pilot houst must work independantly from each other.
Condition: Unknown
Due 21 September 1999
Resolved 18 October 1999
Navigation
Issued 21 August 1999
Resolved
Two way communication must be established between the bridge and the barges.
Condition: Unknown
Due 21 September 1999
Resolved 18 October 1999
Construction/Loadline
Issued 21 August 1999
Resolved
The stern area had many cracks in the hull for the vsl.
Condition: Unknown
Due 21 September 1999
Resolved 18 October 1999
Navigation
Issued 21 August 1999
Resolved
Horn on the vsl was not in proper operating condition.
Condition: Unknown
Due 21 September 1999
Resolved 20 October 1999
Fire Fighting
Issued 21 August 1999
Resolved
All fire hoses and nozzles were missing from the fire stations.
Condition: Unknown
Due 21 September 1999
Resolved 18 October 1999
Electrical
Issued 21 August 1999
Resolved
Fuse boxes onboard did not have the proper blanks or guards on them.
Condition: Unknown
Due 21 September 1999
Resolved 18 October 1999
Fire Fighting
Issued 21 August 1999
Resolved
Portable fire extinguishers were missing, out dated or inproperly secured.
Condition: Unknown
Due 21 September 1999
Resolved 18 October 1999
Construction/Loadline
Issued 21 August 1999
Resolved
Multiple machine guards were missing creating a hazardous condition.
Condition: Unknown
Due 21 September 1999
Resolved 18 October 1999
Construction/Loadline
Issued 21 August 1999
Resolved
Sump pumps placed throughout the bilge leadind directly overboard.
Condition: Unknown
Due 21 August 1999
Resolved 18 October 1999
Deck/Cargo
Issued 21 August 1999
Resolved
Vsl was missing multiple flame screens.
Condition: Unknown
Due 21 September 1999
Resolved 18 October 1999
Electrical
Issued 21 August 1999
Resolved
Battery boxes were missing.
Condition: Unknown
Due 21 September 1999
Resolved 18 October 1999
Electrical
Issued 21 August 1999
Resolved
Lights on the vsl were missing the proper protective covering.
Condition: Unknown
Due 21 September 1999
Resolved 18 October 1999