LEO A MCARTHUR is a towing vessel. The Coast Guard has recorded 33 inspections since 2009, most recently in November 2025, along with 9 deficiencies and 2 operational controls.
Records from 2009 to 2025. Most recent: inspection, 5 November 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it2487 - Displacement, Metric Ton 8215 - Convention (Subpart B), Gross Ton 1299 - Simplified, Gross Ton 3758 - Convention (Subpart B), Net Ton 389 - Simplified, Net Ton 1302 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1980 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 26 September 2025Resolved
General arrangement plans shall clearly show for each deck the various fire sections enclosed by "A" class divisions and "B" class divisions. Vessel's paint locker structural fire protection is missing on two bulkheads and conflicts with vessel's fire control plan.
74 SOLAS (20) 15.2.4.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2025
Resolved 5 November 2025
Resolution: Vessel Class confirmed that bulkheads in space are to be A-0 rated, not A-60, and that the steel bulkheads in the paint locker are rated as A-0. See documents tab for more details.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 27 September 2022Resolved
The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. They shall also be permanently marked on the sides of the ship to the satisfaction of the Administration. The marks shall be plainly visible. The starboard side loadline was not plainly visible due to lack of contrasting color. Loadline was rusted over.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2022
Resolved 3 October 2022
Resolution: Received proper documentation showing deficiency was rectified.
Lifesaving › Lifebuoys › Serviceable
Issued 19 July 2013Resolved
Renewed aft starboard ring buoy.
Action required: 705 - Other - as specified
Due 28 August 2013
Resolved 19 July 2013
Resolution: Boy renewed. Deficiency corrected on the spot.
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 22 March 2011Resolved
LOR applied in conjunction with Canadian LOR. 3 P&S 4P&S and 5 Center tested with low salinity. LOR remains in effect until departure from Great Lakes system at Eisenhower lock in Massena, NY.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2015
Resolution: Deficiency administratively cleared.
1705-Pollution Prevention/Response-Vessel failed to produce 11 Spill Buster oil economy spill kits IAW SOPEP dated 08 may 08. Vessel is prohibited from carrying any oil like product until kits are on board, as verified by Coast Guard.
MARPOL ANNEX I/26
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 August 2009
Resolved 28 August 2009
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiency was rectified.
The class report stated: 12 Spill Buster oil Economy Spill Kits have been received and verified on board in accordance with approved SOPEP.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 24 August 2009Resolved
2035-Fire Fighting-Currently there is no designated paint storage area listed on the fire control plan. All paint and associated materials are being stored in the ballast pump room. This arrangement has not been approved/authorized by the Administration. Storage arrangements need to be approved by the Administration with updates made to the fire control plan.
SOLAS II-2/10
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 24 August 2009
Resolved 28 August 2009
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiency was rectified.
The class report stated: The paint locker on the tugboat has been complemented with water spraying system in accordance with SOLAS.
0936-Occupational Safety-Vessel does not have non-skid flooring in the steering gear room. Install adequate non slip flooring to the satisfaction of class.
SOLAS II-1/29
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 31 August 2009
Resolved 28 August 2009
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiency was rectified.
The class report stated: Adequate non-skid type flooring has been provided to the steering gear room.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 24 August 2009Resolved
0740-Fire Fighting-Emergency fire pump shaft seal is leaking excessively during all modes of operation. Make permanent repairs to the satisfaction of Class.
SOLAS II-2/14
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 August 2009
Resolved 28 August 2009
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiency was rectified.
The class report stated: The damaged mechanical seal has been renewed and Emergency fire pump satisfactorily tested.
1410-Engineering-The no. 2 CPP drain line to the tank is leaking IVO the valve on the CPP unit. Make permanent repairs to the satisfaction of class. SOLAS I-II
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 August 2009
Resolved 28 August 2009
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiency was rectified.
The class report stated: Leaking drain line has been permanently repaired by welding.