Records from 2011 to 2025. Most recent: inspection, 11 December 2025.
Inspection history · 18
11 December 2025
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8291401
29 January 2025
Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8070532
16 October 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8019605
9 May 2024
Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7909284
15 February 2024
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7878884
8 February 2023
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7631483
18 October 2022
Internal Structural Exam · Examination of Repairs · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7577159
18 July 2022
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7510077
4 February 2022
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7384575
3 February 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7054381
29 October 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7054371
6 August 2020
In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7043155
3 February 2020
Administrative Inspection · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6797523
30 January 2019
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6570963
10 January 2019
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6570967
13 February 2018
Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6355064
14 February 2017
Construction Oversight · Administrative Inspection · Annual Inspection · Deficiency Check · Drydock Exam · DAPI Audit · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6083544
9 February 2016
Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5811504
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 11 December 2025
Resolved
Provide a visual an audible indicator for the forward bilge high level alarm.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 December 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 December 2025
Resolved
Provide 2 additional adult life jackets. Vessel restricted to 13 passengers.
Action required: 705 - Other - as specified
Resolved 11 December 2025
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 11 December 2025
Resolved
Mark the adult and child life jacket storage locations with the size and number of life jacket stored inside.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 December 2025
Resolved 11 December 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 December 2025
Resolved
Mark the ring life buoy with the vessel's name in block capital letters.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 December 2025
Resolved 11 December 2025
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 29 January 2025
Resolved
Provide two additional flares so there are a total of 12 flares on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2025
Resolved 30 January 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 29 January 2025
Resolved
Tether the forward deck hatch to its framing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2025
Resolved 30 January 2025
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 29 January 2025
Resolved
Post a life jacket donning placard in a visible location.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2025
Resolved 30 January 2025
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 29 January 2025
Resolved
Mark the life jacket storage location with the type and number of life jackets stored within.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2025
Resolved 30 January 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 January 2025
Resolved
Clearly mark the storage location of the portable fire extinguisher located beneath the aft deck hatch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2025
Resolved 30 January 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 29 January 2025
Resolved
Make the anchor locker hatch watertight.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 February 2025
Resolved 29 January 2025
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 May 2024
Resolved
Received report that vessel ran soft aground on the flats. Vessel was slowly skipping off with the current when sister vessel arrived on scene to tow it off. Issued prior to carrying passenger deficiency to make the vessel available for external hull and internal structural damage survey to assess.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 October 2022
Resolved
The vessel's flexible fill pipe for the port fuel tank is a nonconductor of electricity. Join the metallic sections of the fill pipe (cap and tank) with a conductor (ground wire) for protection against generation of a static charge when filling with fuel.
Action required: 705 - Other - as specified
Resolved 19 October 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 18 October 2022
Resolved
A hatch exposed to the weather must be watertight and the cover must have securing devices and be attached to the hatch frame with captive chains or other devices to prevent its loss. The passenger area hatch covers do not have adequate securing devices. The engine room hatch covers and the forwardmost passenger area hatch cover do not have captive chains attached to the hatch frames.
Action required: 705 - Other - as specified
Resolved 19 October 2022
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 3 February 2021
Resolved
Portable fire extinguishers (02) and Fireboy have not been serviced since 2019.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 February 2021
Resolution: Received photographs of fire servicing stickers/tags on equipment.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 29 October 2020
Resolved
A stanchion near the winch post is not properly seated to the deck. Additionally, there are signs of water ingress through the upper layers of FRP in that area. Issued deficiency to grind back to good FRP, repair, and reseat stanchion to deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 February 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 January 2019
Resolved
Conduct underway operational test of vessels propulsion and steering system in the presence of attending marine inspector.
*Prior to credit drydock
Action required: 705 - Other - as specified
Resolved 11 February 2019
Resolution: Satisfactory sea trail conducted.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 13 February 2018
Resolved
Repair identified hatches for watertight integrity.
Action required: 705 - Other - as specified
Due 20 February 2018
Resolved 16 February 2018
Resolution: Hatches repaired.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 13 February 2018
Resolved
Service B-I portable fire extinguisher (JAN 17).
Action required: 705 - Other - as specified
Due 20 February 2018
Resolved 17 February 2018
Resolution: Fire extinguisher serviced.
Navigation › Piloting/Steering › Marine Charts
Issued 13 February 2018
Resolved
Provide chart for areas operated.
Action required: 705 - Other - as specified
Due 20 February 2018
Resolved 16 February 2018
Resolution: charts provided
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 13 February 2018
Resolved
Bond port/STBD fuel tanks to a common ground.
Action required: 705 - Other - as specified
Due 20 February 2018
Resolved 16 February 2018
Resolution: Port/STBD tanks bonded to common ground.
Electrical › Electrical Distribution System (service) › Fuse
Issued 27 March 2017
Resolved
Fuses at operating station must be of a cartridge type.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 7 April 2017
Resolution: Panel replaced with cartridge type fuses.
Documentation › Markings/Placards › Official Number (US)
Issued 27 March 2017
Resolved
Vessel's official number shall be permanently affixed to the vessel.
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 28 April 2017
Resolution: Official number permanently affixed to the vessel.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 14 February 2017
Resolved
Make repairs to port fuel tank vent and conduct hydrostatic test in the presence of a Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2017
Resolution: Fill pipe was properly welded on, tank was pressure tested with water to 5 psi for 10 minutes. All SAT
Engineering › Bilge Water Management System › Interface Detector
Issued 9 February 2016
Resolved
Provide audible indicator at operating station for high water alarm in battery space.
Action required: 705 - Other - as specified
Due 9 March 2016
Resolved 4 March 2016
Resolution: Vessel installed new audible indicator at operating station for high water alarm in battery space.
Communications › Radio Communications › VHF Radiotelephone
Issued 9 February 2016
Resolved
Program MMSI # into Digital Select Calling VHF radio. FCC.
Action required: 705 - Other - as specified
Due 9 March 2016
Resolved 4 March 2016
Resolution: Vessel proprammed MMSI # 367447330 into DSC VHF radio.