Records from 2005 to 2012. Most recent: inspection, 30 May 2012.
Inspection history · 15
30 May 2012
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4329021
6 February 2012
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4239352
6 July 2011
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4074654
3 February 2011
COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3937958
4 January 2011
Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3920228
22 January 2010
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3668282
28 January 2009
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3401343
20 January 2009
Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3396963
30 January 2008
Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3143949
28 January 2008
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3137833
12 October 2007
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3082934
10 October 2007
Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3076765
11 April 2006
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2622379
3 February 2006
Initial Certification
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2578175
14 December 2005
Construction Oversight · COI Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2551331
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 6 February 2012
Resolved
Acquire means for emergency steering
Due 15 February 2012
Resolved 22 February 2012
Stability › Watertight Integrity › General
Issued 6 February 2012
Resolved
Forward deck hatch must be watertight
Due 15 February 2012
Resolved 15 February 2012
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 February 2012
Resolved
Change battery in strobe light
Due 15 February 2012
Resolved 15 February 2012
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 February 2012
Resolved
Repair starboard navigation light
Due 15 February 2012
Resolved 15 February 2012
Construction/Loadline › Structures › Superstructure
Issued 6 February 2012
Resolved
Repair 02 fractures on portside inflation arch
Due 15 February 2012
Resolved 15 February 2012
Stability › Watertight Integrity › General
Issued 6 February 2012
Resolved
Re-caulk forward engine room hatch insert.
Due 15 February 2012
Resolved 15 February 2012
Documentation › Certificates/Documents › FCC SSL
Issued 3 February 2011
Resolved
Acquire valid station license for vessel.
Due 3 February 2011
Resolved 3 February 2011
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 3 February 2011
Resolved
Acquire valid radio safety telephony certificate for vessel
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 February 2011
Resolved 3 February 2011
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 3 February 2011
Resolved
Label life ring buoy with vessel name.
Due 3 February 2011
Resolved 3 February 2011
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 3 February 2011
Resolved
Anchor light must be operable
Due 3 February 2011
Resolved 3 February 2011
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 February 2011
Resolved
Replace expired medications in medicine chest
Due 3 February 2011
Resolved 3 February 2011
Communications › Radio Communications › EPIRB
Issued 3 February 2011
Resolved
Properly label hydrostatic release.
Due 3 February 2011
Resolved 3 February 2011
Stability › Watertight Integrity › General
Issued 4 January 2011
Resolved
Install gasket on watertight hatch.
Due 7 January 2011
Resolved 5 January 2011
Fire Fighting › Portable CO2 Fire Extinguisher › Marking
Issued 4 January 2011
Resolved
Mark location of forward portable fire extinguisher.
Due 7 January 2011
Resolved 5 January 2011
Documentation › Markings/Placards › Warning Signs
Issued 22 January 2010
Resolved
emergency broadcast placard needs to be replaced.
Due 22 January 2010
Resolved 22 January 2010
Lifesaving › Hand Flares › Quantity
Issued 22 January 2010
Resolved
Vessel , must acquire 05 more hand flares.
Due 22 January 2010
Resolved 22 January 2010
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 22 January 2010
Resolved
Vessel must acquire 01 portable lights for the engine room space.
Due 22 January 2010
Resolved 22 January 2010
Communications › Alarms/Indicators › Bilge Alarm
Issued 28 January 2008
Resolved
Label bilge high level alarms at the indicator panel.
Due 29 February 2008
Resolved 30 January 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 January 2008
Resolved
Prove proper operation of the starboard navigation light. Vessel is restricted to daylight operations until this requirement is met.
Due 28 January 2008
Resolved 30 January 2008
Communications › Radio Communications › EPIRB
Issued 28 January 2008
Resolved
Replace the hydrostatic release on the EPIRB installation.
Due 29 February 2008
Resolved 30 January 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 12 October 2007
Resolved
Prove proper operation of port navigation light. Vessel is restricted to daylight operations only.
Due 12 October 2007
Resolved 30 January 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 October 2007
Resolved
Replace first aid kit with approved type.
Due 19 October 2007
Resolved 30 January 2008
Documentation › Certificates/Documents › Certificate of Inspection
Issued 10 October 2007
Resolved
Satisfactorily complete an annual inspection prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 October 2007
Resolved 12 October 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 February 2006
Resolved
Properly mount floating waterlight in way of ring lifebuoy. Vessel restricted to daylight operation only until complete.
Action required: 705 - Other - as specified
Resolved 3 February 2006
Operations/Management › Drills/Instruction › Not Conducted
Issued 14 December 2005
Resolved
Underway portion of COI not conducted due to wx. Conduct u/w tests (drills & op test machinery).
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2006
Resolved 5 February 2009
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 December 2005
Resolved
New construction in Sec Del Bay OCMI zone, temp COI issued. Owner plans to operate in Key West FL. Conduct New To Zone inspection and route change prior to carrying passengers in New Zone.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2006
Resolved 5 February 2009
Communications › Radio Communications › EPIRB
Issued 14 December 2005
Resolved
EPIRB not supplied by builder. Vessel has Limited C/W route with no lifesaving & no subdivisions. Provide EPIRB prior to operation in Limited C/W with in 3NM warm waters.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2006
Resolved 5 February 2009
Lifesaving › Lifejacket/PFD (Type IV) › Lights
Issued 14 December 2005
Resolved
Life Ring Float Light battery not provided by builder, provide working float light & ensure proper installation prior to carrying passengers at night.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2006
Resolved 5 February 2009
Engineering › Fuel Oil Service System › Tank
Issued 14 December 2005
Resolved
Fuel tank post installation test not conducted, test fuel tank IAW 46 CFR 182.440(c)(2).
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2006
Resolved 5 February 2009
Engineering › Steering Gear System › Rudder Stock
Issued 14 December 2005
Resolved
Provide emergency tiller.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2006
Resolved 5 February 2009
Documentation › Certificates/Documents › FCC SSL
Issued 14 December 2005
Resolved
Vessel equiped with VHF radio, provide FCC SSL, Radio Safety Certificate & Operator Permit prior to carrying passengers beyond 1000' from shore.
Action required: 705 - Other - as specified
Due 18 February 2006
Resolved 5 February 2009
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 14 December 2005
Resolved
Unable to run engine to test Pre-engineered fixed fire fighting system automatic shutdowns. Prove proper operation of auto shut down.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2006
Resolved 5 February 2009
Fire Fighting › Fire Bucket › Availability
Issued 14 December 2005
Resolved
Builder did not supply fire buckets, provide three fire buckets.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2006
Resolved 5 February 2009
Documentation › Markings/Placards › Official Number (US)
Issued 14 December 2005
Resolved
Owner planed to paint vessel therefore markings not applied. Provide proper markings (name & hailing port).
Action required: 705 - Other - as specified
Due 18 February 2006
Resolved 5 February 2009
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 14 December 2005
Resolved
Mooring lines not provided by builder. Provide mooring lines.
Action required: 705 - Other - as specified
Due 18 February 2006
Resolved 5 February 2009
Navigation › Piloting/Steering › Marine Charts
Issued 14 December 2005
Resolved
Provide charts & pubs for op area.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2006
Resolved 5 February 2009
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 14 December 2005
Resolved
Prove enrollment in chemical testing program.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2006
Resolved 5 February 2009