MAURY USCG vessel records
← All vessels

KEY WEST FURY

KEY WEST FURY is a 2005 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2016, most recently in December 2025, along with 66 deficiencies, 1 operational control and 9 casualty investigations between 2005 and 2023.

Records from 2005 to 2025. Most recent: inspection, 11 December 2025.

Built
2005
Last inspected
11 December 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDC6829
747670
Flag
UNITED STATES
Maury page id
psix-747670

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded1
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)64.7 ft × 38.0 ft × 7.0 ft
Registered tonnagegross 36 / net 29
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMIDSHIP MARINE INC · HARVEY, LA, UNITED STATES · built 2005
Hull materialAluminum
PropulsionDiesel Direct
Hull shapeShip
Hull configurationTwin Hull
Hailing portKEY WEST, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 1 July 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it36 - Simplified, Gross Ton
29 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

PACIFIC FURY Passenger (Inspected) · MISLE 4437 · 26 September 2023 · activity 7812646

Inspection history · 16

11 December 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8291441
4 February 2025 Drydock Exam · Examination of Repairs · Internal Structural Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8091702
10 December 2024 Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8043785
29 July 2024 In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7967529
15 February 2024 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7878883
26 September 2023 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7812646
25 January 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7626708
13 December 2022 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7606057
7 December 2021 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7360415
6 January 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7054127
4 December 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7054110
28 August 2019 COI Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6797335
30 January 2019 Deficiency Check · Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6571033
13 February 2018 Annual Inspection · Administrative Inspection · DAPI Audit · Internal Structural Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6355017
18 January 2017 DAPI Audit · Administrative Inspection · Deficiency Check · Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6072507
18 February 2016 DAPI Audit · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5815522

Deficiency record · 66

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 December 2025 Resolved
Replace the pressure gauge at the fire pump outlet to provide an accurate psi reading.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 December 2025
Resolved 19 December 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 December 2025 Resolved
Mount the 10-B:C portable fire extinguisher at the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 December 2025
Resolved 19 December 2025
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 11 December 2025 Resolved
Mark the adult and child life jacket storage locations with the size and number of life jacket inside.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 December 2025
Resolved 19 December 2025
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 11 December 2025 Resolved
Provide a life jacket donning placard with donning instructions for each different style of life jacket on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 December 2025
Resolved 19 December 2025
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 February 2025 Resolved
Conduct post mast inspection sea-trials with sails raised prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 February 2025
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 4 February 2025 Resolved
Provide third-party rigging survey and updated inventory.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2025
Resolved 26 February 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 December 2024 Resolved
10 type I adult life jackets no longer had original buoyancy (compressed flat and would not regain shape). Vessel restricted to carrying 118 passengers until 10 new adult life jackets have been provided and labeled (132 total).
Action required: 705 - Other - as specified
Resolved 12 December 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 December 2024 Resolved
Provide a spanner wrench in the proximity of the fire hydrant.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 December 2024
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 December 2024 Resolved
Provide a stern light.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 December 2024
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 15 February 2024 Resolved
Vessel operates in warm waters and is required to have survival craft for 50% of the 132 total allowed persons on board (61). All equipped life floats are no longer in serviceable condition. Vessel is restricted to operating within three miles of shore.
Action required: 705 - Other - as specified
Resolved 29 February 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 December 2022 Resolved
Vessel's fire hose nozzle was missing a pin in the handle attachment and was seized in the solid stream setting. Provide a fire hose nozzle capable of both solid stream and a spray pattern.
Action required: 10 - Deficiency Rectified
Resolved 13 December 2022
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 7 December 2021 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Install guards in front of or covering the rotating machinery on the port and starboard engines.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2022
Resolved 13 December 2022
Resolution: Company fabricated and installed guards for the rotating machinery in the port and starboard engine rooms.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 4 December 2020 Resolved
The vessel must have submersion marks as detailed on the Stability Letter. One mark on the port and starboard side amidships will suffice. Complete marking at next drydock.
Action required: 705 - Other - as specified
Due 31 January 2021
Resolved 10 February 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 August 2019 Resolved
No listing of deck hand on consortium paperwork for participation in alcohol/drug screening program onboard.
Action required: 10 - Deficiency Rectified
Due 12 December 2019
Resolved 12 December 2019
Resolution: Company provided evidence of pre-employment testing conducted for individual in question.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 August 2019 Resolved
Stowage areas for lifejackets not properly marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 December 2019
Resolved 27 February 2020
Resolution: labled life jacket stowage compartments
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 August 2019 Resolved
AUTOMATIC BILGE PUMPING OVERBOARD VALVES IN MULTIPLE LOCATIONS ARE NOT IN PROPER WORKING ORDER. ENSURE THAT ALL OVERBOARD VALVES OPERATE SMOOTHLY. ADDITIONALLY, MULTIPLE OVERBOARD DISCHARGE VALVES FOR AUTOMATIC BILGE PUMPS ARE SEIZED AND REQUIRE MAINTENANCE.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2019
Resolved 25 February 2020
Resolution: valves are properly operational
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 28 August 2019 Resolved
BOTH HATCHES TO THE LAZARETTE SPACES ARE LOOSE AND NEED TO BE TIGHTENED TO ENSURE WATERTIGHT INTEGRITY.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2019
Resolved 27 February 2020
Resolution: new gaskets have been installed and dogs have tightened
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 August 2019 Resolved
SAFETY NETTING ON BOTH THE BOW AS WELL AS OUTBOARD LOCATIONS ON PORT AND STARBOARD STERN DOES NOT MEET THE REQUIREMENT FOR EXCURSION VESSELS OF MAINTAINING SPACES OF NO MORE THAN FOUR INCHES BETWEEN ACCESS OVERBOARD. ENSURE THAT ALL GAPS TO OVERBOARD AREAS BELOW THE MANDATORY DECK RAIL HEIGHT OF 39.5 INCHES ARE LESS THAN FOUR INCHES EXCLUDING EMBARKATION AREAS AND AREAS FOR MOORING.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2019
Resolved 27 February 2020
Resolution: Additional safety lines have been placed on the bow and aft port and starboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 February 2019 Resolved
Post Stability Letter and COI
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 21 February 2019 Resolved
Connect painter line to weak link and liferafts
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 February 2019 Resolved
Replace SOLAS tape on all identified pieces of life saving equipment (PFD's and ring buoy).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 February 2019 Resolved
Label all PFD stowage locations
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 21 February 2019 Resolved
Post life jacket donning placard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 April 2019
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 21 February 2019 Resolved
Provide light for magnetic compass.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 February 2019 Resolved
Provide corrosion resistant clip for ring buoy floating light.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 April 2019
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 21 February 2019 Resolved
Provide GPS input for VHF radio
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 April 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 February 2019 Resolved
Post emergency broadcast placard at operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 April 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 February 2019 Resolved
Demonstrate operation of visual indicatoir on port engine room fire boy system.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 April 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 February 2019 Resolved
Provide permanent connection on starboard battery (remove wingnuts).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 April 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 February 2019 Resolved
Provide dripproof cover for receptacle behind bar.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 April 2019
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 21 February 2019 Resolved
Install light covers in port and starboard electrical space.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 April 2019
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 February 2019 Resolved
Permanently mount all submersible bilge pumps.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 April 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 February 2019 Resolved
Mouse shackles on rig.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 April 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 February 2019 Resolved
Connect grounding wire to ground on inverter portside.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 April 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 January 2019 Resolved
Exhaust box in lazarette has 4 holes, leaking exhaust and water. Repair/Replace
Action required: 705 - Other - as specified
Resolved 21 February 2019
Resolution: Exhaust box replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 30 January 2019 Resolved
Watertight bulkhead between the engine room and head has a hole approx, 3 inches up from the hull. Submit plan to OCMI for repair.
Action required: 705 - Other - as specified
Resolved 21 February 2019
Resolution: WTB repaired.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 30 January 2019 Resolved
Provide contract for fabrication and installation of Quick acting watertight doors.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 April 2019
Resolution: approved for next dry dock
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 January 2019 Resolved
Conduct underway operational test of sailing rig under full sail per approved sail plan in the presence of attending marine inspector.
Action required: 705 - Other - as specified
Resolved 21 February 2019
Resolution: Satisfactory underway sail conducted.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 13 February 2018 Resolved
Demonstrate automatic shutdown ability for all engines in STBD E/R when fixed fire extinguishing system is energized.
Action required: 705 - Other - as specified
Due 20 February 2018
Resolved 23 February 2018
Resolution: All engines shutdown upon activation of fireboy system.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 13 February 2018 Resolved
Hydrostatically test or renew port firboy cylinder. (over 12 years old).
Action required: 705 - Other - as specified
Due 20 February 2018
Resolved 23 February 2018
Resolution: New cyclinder installed on vessel.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 13 February 2018 Resolved
Renew gaskets on port engine room door to provide watertight capability.
Due 20 February 2018
Resolved 13 February 2018
Resolution: Gasket renewed, light tested, all sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 February 2018 Resolved
Remove dead-end wiring in port MSD space.
Action required: 705 - Other - as specified
Due 20 February 2018
Resolved 23 February 2018
Resolution: Dead-end wires removed
Electrical › Electrical Distribution System (service) › Junction Box
Issued 13 February 2018 Resolved
Renew electrical junction box near mast step.
Action required: 705 - Other - as specified
Due 20 February 2018
Resolved 15 February 2018
Resolution: new box installed.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 13 February 2018 Resolved
Renew Port/STBD hinged watertight doors with doors fitted with quick action closing devices operable from both sides.
Action required: 705 - Other - as specified
Due 31 January 2019
Resolved 2 March 2020
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 13 February 2018 Resolved
Remove power inverter from vessel, including all wiring associated with inverter. Cease all operations with inverter.
Action required: 705 - Other - as specified
Due 13 February 2018
Resolved 23 February 2018
Resolution: Inverter removed.
Communications › Radio Communications › VHF Radiotelephone
Issued 23 February 2017 Resolved
Provide GPS input for VHF radio.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 11 April 2017
Resolution: GPS integrated into VHF radio.
Electrical › Electric Generation Source (service) › Generator
Issued 23 February 2017 Resolved
Submit plans for installed inverter to include manual for inverter, circuit protection, wire size, length of wire run, wire type to the local OCMI for approval prior to operation of inverter.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 2 February 2018
Resolution: Added to new ANN activity (6355017).
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 18 January 2017 Resolved
Properly protect rotating machinery with adequate cover, guard, or rails. Port and Starboard engines have exposed hazards.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 10 April 2017
Resolution: Signage was previously approved in lieu of guards for rotating machinery. See special note.
Stability › Watertight Integrity › General
Issued 18 January 2017 Resolved
Repair/replace gaskets on port and starboard engine room deck hatches to achieve water tightness.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 23 February 2017
Resolution: Gaskets renewed.
Stability › Watertight Integrity › General
Issued 18 January 2017 Resolved
Repair/replace gasket on port engine room watertight door to achieve water tightness.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 23 February 2017
Resolution: Gaskets renewed.
Electrical › Electrical Distribution System (service) › Fuse
Issued 18 January 2017 Resolved
Fuses in panel near port engine room are not a cartridge type. Renew with cartridge type fuses.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 9 March 2017
Resolution: Fuse panel replaced with cartridge type.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 18 January 2017 Resolved
Replace port and starboard shaft cutlass bearings.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 20 January 2017
Resolution: Bearings replaced.
Construction/Loadline › Structures › Deck Plating
Issued 18 January 2017 Resolved
Provide access to port/starboard toilet and washing space for examination below spaces.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 20 January 2017
Resolution: 6" inspections port installed.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 18 January 2017 Resolved
Repair/replace exhaust piping for generator in starboard side engine room.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 23 February 2017
Resolution: Exhaust piping renewed.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 18 January 2017 Resolved
Repair/replace exhaust piping for starboard engine in lazarette space.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 9 March 2017
Resolution: Exhaust piping renewed.
Engineering › Sea-water System (primary cooling) › Valve
Issued 18 January 2017 Resolved
Repair/renew seas suction valves for starboard side generator and discharge for sewage.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 20 January 2017
Resolution: Valve renewed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 18 January 2017 Resolved
Provide 02 B-II portable fire extinguishers that are operational.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 February 2017
Resolution: Vessel provided 02 new B-II portable fire extinguishers.
Documentation › Certificates/Documents › Stability Letter
Issued 18 February 2016 Resolved
Post all pages of CG issued Stability Letter
Action required: 705 - Other - as specified
Due 18 February 2016
Resolved 18 February 2016
Resolution: Vessel posted Stability Letter.
Documentation › Markings/Placards › Lifejacket Placard
Issued 18 February 2016 Resolved
Post donning placard for each model of life jacket on board.
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 4 May 2016
Resolution: Vessel posted a donning placard for each model of life jacket on board.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 18 February 2016 Resolved
Fix life jacket storage labels.
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 4 May 2016
Resolution: Vessel re-labeled life jacket storage locations.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 18 February 2016 Resolved
Seperate adult and child size life jacket storage areas.
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 4 May 2016
Resolution: Vessel seperated adult and child size life jackets.
Documentation › Markings/Placards › Capacity Marking
Issued 18 February 2016 Resolved
Post maximum capacity placard for upper deck passenger area.
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 4 May 2016
Resolution: Vessel posted maximum capacity placard for upper deck.
Lifesaving › Lifefloat › Painter
Issued 18 February 2016 Resolved
Replace main painter line on lifefloats
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 4 May 2016
Resolution: Vessel replaced lifefloat painter line.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 18 February 2016 Resolved
Install approved fire extinguisher bracket for B-1 fire extinguisher next to operating station.
Action required: 705 - Other - as specified
Due 18 February 2016
Resolved 18 February 2016
Resolution: Vessel installed approved bracket.
Communications › Alarms/Indicators › Bilge Alarm
Issued 18 February 2016 Resolved
Install visual indicator for all automatic bilge pumps or make them manual operation only.
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 4 May 2016
Resolution: Vessel made all submersible bilge pumps manual operation only.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 18 February 2016 Resolved
Ensure all safety equipment on board is appropriate and sufficient for emergency instructions.
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 4 May 2016
Resolution: Vessel updated emergency instructions to reflect operations.

Casualty record · 9

17 October 2005Routine · role: Involved in a Marine Casualty · activity 2516008
16 February 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 2587039
20 March 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2605901
28 November 2008Routine · role: Involved in a Marine Casualty · activity 3370839
6 July 2011Routine · role: Involved in a Marine Investigation (non-casualty) · serious marine incident, as classified · 2 injured · activity 4074654
8 October 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4180886
21 January 2012Routine · role: Involved in a Marine Casualty · 1 injured · activity 4254247
16 July 2013Routine · role: Involved in a Marine Casualty · 1 injured · activity 4657357
26 September 2023Routine · role: Involved in a Marine Investigation (non-casualty) · activity 7812646
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.