Records from 2005 to 2025. Most recent: inspection, 11 December 2025.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 December 2025
Resolved
Replace the pressure gauge at the fire pump outlet to provide an accurate psi reading.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 December 2025
Resolved 19 December 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 December 2025
Resolved
Mount the 10-B:C portable fire extinguisher at the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 December 2025
Resolved 19 December 2025
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 11 December 2025
Resolved
Mark the adult and child life jacket storage locations with the size and number of life jacket inside.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 December 2025
Resolved 19 December 2025
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 11 December 2025
Resolved
Provide a life jacket donning placard with donning instructions for each different style of life jacket on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 December 2025
Resolved 19 December 2025
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 February 2025
Resolved
Conduct post mast inspection sea-trials with sails raised prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 February 2025
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 4 February 2025
Resolved
Provide third-party rigging survey and updated inventory.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2025
Resolved 26 February 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 December 2024
Resolved
10 type I adult life jackets no longer had original buoyancy (compressed flat and would not regain shape). Vessel restricted to carrying 118 passengers until 10 new adult life jackets have been provided and labeled (132 total).
Action required: 705 - Other - as specified
Resolved 12 December 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 December 2024
Resolved
Provide a spanner wrench in the proximity of the fire hydrant.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 December 2024
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 December 2024
Resolved
Provide a stern light.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 December 2024
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 15 February 2024
Resolved
Vessel operates in warm waters and is required to have survival craft for 50% of the 132 total allowed persons on board (61). All equipped life floats are no longer in serviceable condition. Vessel is restricted to operating within three miles of shore.
Action required: 705 - Other - as specified
Resolved 29 February 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 December 2022
Resolved
Vessel's fire hose nozzle was missing a pin in the handle attachment and was seized in the solid stream setting. Provide a fire hose nozzle capable of both solid stream and a spray pattern.
Action required: 10 - Deficiency Rectified
Resolved 13 December 2022
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 7 December 2021
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Install guards in front of or covering the rotating machinery on the port and starboard engines.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2022
Resolved 13 December 2022
Resolution: Company fabricated and installed guards for the rotating machinery in the port and starboard engine rooms.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 4 December 2020
Resolved
The vessel must have submersion marks as detailed on the Stability Letter. One mark on the port and starboard side amidships will suffice. Complete marking at next drydock.
Action required: 705 - Other - as specified
Due 31 January 2021
Resolved 10 February 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 August 2019
Resolved
No listing of deck hand on consortium paperwork for participation in alcohol/drug screening program onboard.
Action required: 10 - Deficiency Rectified
Due 12 December 2019
Resolved 12 December 2019
Resolution: Company provided evidence of pre-employment testing conducted for individual in question.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 August 2019
Resolved
Stowage areas for lifejackets not properly marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 December 2019
Resolved 27 February 2020
Resolution: labled life jacket stowage compartments
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 August 2019
Resolved
AUTOMATIC BILGE PUMPING OVERBOARD VALVES IN MULTIPLE LOCATIONS ARE NOT IN PROPER WORKING ORDER. ENSURE THAT ALL OVERBOARD VALVES OPERATE SMOOTHLY. ADDITIONALLY, MULTIPLE OVERBOARD DISCHARGE VALVES FOR AUTOMATIC BILGE PUMPS ARE SEIZED AND REQUIRE MAINTENANCE.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2019
Resolved 25 February 2020
Resolution: valves are properly operational
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 28 August 2019
Resolved
BOTH HATCHES TO THE LAZARETTE SPACES ARE LOOSE AND NEED TO BE TIGHTENED TO ENSURE WATERTIGHT INTEGRITY.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2019
Resolved 27 February 2020
Resolution: new gaskets have been installed and dogs have tightened
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 August 2019
Resolved
SAFETY NETTING ON BOTH THE BOW AS WELL AS OUTBOARD LOCATIONS ON PORT AND STARBOARD STERN DOES NOT MEET THE REQUIREMENT FOR EXCURSION VESSELS OF MAINTAINING SPACES OF NO MORE THAN FOUR INCHES BETWEEN ACCESS OVERBOARD. ENSURE THAT ALL GAPS TO OVERBOARD AREAS BELOW THE MANDATORY DECK RAIL HEIGHT OF 39.5 INCHES ARE LESS THAN FOUR INCHES EXCLUDING EMBARKATION AREAS AND AREAS FOR MOORING.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2019
Resolved 27 February 2020
Resolution: Additional safety lines have been placed on the bow and aft port and starboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 February 2019
Resolved
Post Stability Letter and COI
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 21 February 2019
Resolved
Connect painter line to weak link and liferafts
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 February 2019
Resolved
Replace SOLAS tape on all identified pieces of life saving equipment (PFD's and ring buoy).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 February 2019
Resolved
Label all PFD stowage locations
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 21 February 2019
Resolved
Post life jacket donning placard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 April 2019
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 21 February 2019
Resolved
Provide light for magnetic compass.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 February 2019
Resolved
Provide corrosion resistant clip for ring buoy floating light.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 April 2019
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 21 February 2019
Resolved
Provide GPS input for VHF radio
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 April 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 February 2019
Resolved
Post emergency broadcast placard at operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 April 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 February 2019
Resolved
Demonstrate operation of visual indicatoir on port engine room fire boy system.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 April 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 February 2019
Resolved
Provide permanent connection on starboard battery (remove wingnuts).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 April 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 February 2019
Resolved
Provide dripproof cover for receptacle behind bar.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 April 2019
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 21 February 2019
Resolved
Install light covers in port and starboard electrical space.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 April 2019
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 February 2019
Resolved
Permanently mount all submersible bilge pumps.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 April 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 February 2019
Resolved
Mouse shackles on rig.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 April 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 February 2019
Resolved
Connect grounding wire to ground on inverter portside.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 April 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 January 2019
Resolved
Exhaust box in lazarette has 4 holes, leaking exhaust and water. Repair/Replace
Action required: 705 - Other - as specified
Resolved 21 February 2019
Resolution: Exhaust box replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 30 January 2019
Resolved
Watertight bulkhead between the engine room and head has a hole approx, 3 inches up from the hull. Submit plan to OCMI for repair.
Action required: 705 - Other - as specified
Resolved 21 February 2019
Resolution: WTB repaired.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 30 January 2019
Resolved
Provide contract for fabrication and installation of Quick acting watertight doors.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 April 2019
Resolution: approved for next dry dock
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 January 2019
Resolved
Conduct underway operational test of sailing rig under full sail per approved sail plan in the presence of attending marine inspector.
Action required: 705 - Other - as specified
Resolved 21 February 2019
Resolution: Satisfactory underway sail conducted.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 13 February 2018
Resolved
Demonstrate automatic shutdown ability for all engines in STBD E/R when fixed fire extinguishing system is energized.
Action required: 705 - Other - as specified
Due 20 February 2018
Resolved 23 February 2018
Resolution: All engines shutdown upon activation of fireboy system.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 13 February 2018
Resolved
Hydrostatically test or renew port firboy cylinder. (over 12 years old).
Action required: 705 - Other - as specified
Due 20 February 2018
Resolved 23 February 2018
Resolution: New cyclinder installed on vessel.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 13 February 2018
Resolved
Renew gaskets on port engine room door to provide watertight capability.
Due 20 February 2018
Resolved 13 February 2018
Resolution: Gasket renewed, light tested, all sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 February 2018
Resolved
Remove dead-end wiring in port MSD space.
Action required: 705 - Other - as specified
Due 20 February 2018
Resolved 23 February 2018
Resolution: Dead-end wires removed
Electrical › Electrical Distribution System (service) › Junction Box
Issued 13 February 2018
Resolved
Renew electrical junction box near mast step.
Action required: 705 - Other - as specified
Due 20 February 2018
Resolved 15 February 2018
Resolution: new box installed.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 13 February 2018
Resolved
Renew Port/STBD hinged watertight doors with doors fitted with quick action closing devices operable from both sides.
Action required: 705 - Other - as specified
Due 31 January 2019
Resolved 2 March 2020
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 13 February 2018
Resolved
Remove power inverter from vessel, including all wiring associated with inverter. Cease all operations with inverter.
Action required: 705 - Other - as specified
Due 13 February 2018
Resolved 23 February 2018
Resolution: Inverter removed.
Communications › Radio Communications › VHF Radiotelephone
Issued 23 February 2017
Resolved
Provide GPS input for VHF radio.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 11 April 2017
Resolution: GPS integrated into VHF radio.
Electrical › Electric Generation Source (service) › Generator
Issued 23 February 2017
Resolved
Submit plans for installed inverter to include manual for inverter, circuit protection, wire size, length of wire run, wire type to the local OCMI for approval prior to operation of inverter.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 2 February 2018
Resolution: Added to new ANN activity (6355017).
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 18 January 2017
Resolved
Properly protect rotating machinery with adequate cover, guard, or rails. Port and Starboard engines have exposed hazards.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 10 April 2017
Resolution: Signage was previously approved in lieu of guards for rotating machinery. See special note.
Stability › Watertight Integrity › General
Issued 18 January 2017
Resolved
Repair/replace gaskets on port and starboard engine room deck hatches to achieve water tightness.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 23 February 2017
Resolution: Gaskets renewed.
Stability › Watertight Integrity › General
Issued 18 January 2017
Resolved
Repair/replace gasket on port engine room watertight door to achieve water tightness.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 23 February 2017
Resolution: Gaskets renewed.
Electrical › Electrical Distribution System (service) › Fuse
Issued 18 January 2017
Resolved
Fuses in panel near port engine room are not a cartridge type. Renew with cartridge type fuses.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 9 March 2017
Resolution: Fuse panel replaced with cartridge type.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 18 January 2017
Resolved
Replace port and starboard shaft cutlass bearings.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 20 January 2017
Resolution: Bearings replaced.
Construction/Loadline › Structures › Deck Plating
Issued 18 January 2017
Resolved
Provide access to port/starboard toilet and washing space for examination below spaces.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 20 January 2017
Resolution: 6" inspections port installed.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 18 January 2017
Resolved
Repair/replace exhaust piping for generator in starboard side engine room.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 23 February 2017
Resolution: Exhaust piping renewed.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 18 January 2017
Resolved
Repair/replace exhaust piping for starboard engine in lazarette space.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 9 March 2017
Resolution: Exhaust piping renewed.
Engineering › Sea-water System (primary cooling) › Valve
Issued 18 January 2017
Resolved
Repair/renew seas suction valves for starboard side generator and discharge for sewage.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 20 January 2017
Resolution: Valve renewed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 18 January 2017
Resolved
Provide 02 B-II portable fire extinguishers that are operational.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 February 2017
Resolution: Vessel provided 02 new B-II portable fire extinguishers.
Documentation › Certificates/Documents › Stability Letter
Issued 18 February 2016
Resolved
Post all pages of CG issued Stability Letter
Action required: 705 - Other - as specified
Due 18 February 2016
Resolved 18 February 2016
Resolution: Vessel posted Stability Letter.
Documentation › Markings/Placards › Lifejacket Placard
Issued 18 February 2016
Resolved
Post donning placard for each model of life jacket on board.
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 4 May 2016
Resolution: Vessel posted a donning placard for each model of life jacket on board.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 18 February 2016
Resolved
Fix life jacket storage labels.
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 4 May 2016
Resolution: Vessel re-labeled life jacket storage locations.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 18 February 2016
Resolved
Seperate adult and child size life jacket storage areas.
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 4 May 2016
Resolution: Vessel seperated adult and child size life jackets.
Documentation › Markings/Placards › Capacity Marking
Issued 18 February 2016
Resolved
Post maximum capacity placard for upper deck passenger area.
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 4 May 2016
Resolution: Vessel posted maximum capacity placard for upper deck.
Lifesaving › Lifefloat › Painter
Issued 18 February 2016
Resolved
Replace main painter line on lifefloats
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 4 May 2016
Resolution: Vessel replaced lifefloat painter line.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 18 February 2016
Resolved
Install approved fire extinguisher bracket for B-1 fire extinguisher next to operating station.
Action required: 705 - Other - as specified
Due 18 February 2016
Resolved 18 February 2016
Resolution: Vessel installed approved bracket.
Communications › Alarms/Indicators › Bilge Alarm
Issued 18 February 2016
Resolved
Install visual indicator for all automatic bilge pumps or make them manual operation only.
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 4 May 2016
Resolution: Vessel made all submersible bilge pumps manual operation only.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 18 February 2016
Resolved
Ensure all safety equipment on board is appropriate and sufficient for emergency instructions.
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 4 May 2016
Resolution: Vessel updated emergency instructions to reflect operations.