Records from 2002 to 2026. Most recent: inspection, 18 March 2026.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 24 March 2026
Resolved
The Cat 1 EPIRB's battery has expired. Replace battery or provide and register a new Cat 1 EPIRB prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2026
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 4 April 2024
Resolved
Vessel operates in warm waters and is required to have survival craft for 50% of the 132 total allowed persons on board (61). Two of three equipped life floats (25 capacity each) are no longer in serviceable condition. Vessel is restricted to operating within three miles of shore when carrying more than 50 total persons on board.
Action required: 705 - Other - as specified
Resolved 25 April 2024
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 September 2023
Resolved
Vessel sustained damage to the starboard side of the forward cross bar. Specifically:
- The forward bracket connecting the starboard hull to the cross bar was crumpled and the welds were sheared.
- A one foot section of the bottom plate of the cross bar was pulled backwards breaking the weld and bending/tearing the plate.
Complete repairs and conduct a third-party rigging inspection prior to carrying passengers with sails raised.
Action required: 705 - Other - as specified
Resolved 6 October 2023
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 15 December 2022
Resolved
Clearly mark each life jacket stowage location with the number and type of life jacket inside.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 December 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 15 December 2022
Resolved
Clearly mark the maximum number of passengers (56) allowed on the upper deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 December 2022
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 15 December 2022
Resolved
01 of 03 life float waterlights had a cracked housing and could no longer keep the battery compartment watertight. Replace waterlight.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 December 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 December 2021
Resolved
The vessel's mainsail had tears in the leech and luff. Replace mainsail prior to carrying passengers under sail.
Action required: 705 - Other - as specified
Resolved 2 December 2021
Resolution: Vessel rep replaced torn mainsail with a temporary sail.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 2 December 2021
Resolved
The float-free link end of the life float painter extends beyond the bottom of the painter's canister preventing tension from being placed on the link. Stow the painter in a manner to allow the life floats to float-free. Prior to operating beyond 3 miles from shore.
Action required: 705 - Other - as specified
Resolved 2 December 2021
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 2 December 2021
Resolved
The compartment containing the manual activation for the pre-engineered fixed gas fire extinguishing system is not separated from the space it protects. Seal the cable run in the Fireboy manual pull compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 January 2022
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 December 2020
Resolved
VESSEL'S ENGINE ROOMS ARE NOT PROPERLY SEALED TO BE VAPOR TIGHT FOR SPACE PROTECTED BY PRE-ENGINEERED FIRE FIGHTING SYSTEM. SPECIFICALLY, THERE IS A LARGE MAN HOLE ON THE AFT OVERHEAD FOR BOTH THE PORT AND STARBOARD ENGINE ROOMS THAT WILL ALLOW FIRE EXTINGUISHING AGENT TO ESCAPE THE ENGINE ROOM AREA INTO AN APPROXIMATE 2 FOOT BY THREE FOOT BY FIFTEEN FOOT COFFERDAM/WIRE RUN. IT IS NOT CLEAR WHETHER THAT SPACE HAS BEEN ACCOUNTED FOR WITH THE SIZING OF THE BOTTLE INSTALLED TO PROPERLY EXTINGUISH A FIRE. ENSURE ENGINE ROOM IS VAPOR TIGHT TO ALLOW FOR PROPER FIRE EXTINGUISHING CAPABILITY OF FIRE-BOY SYSTEM OR PROVIDE MEASUREMENTS AND DOCUMENTATION ATTESTING TO THE SUFFICIENT SIZE OF BOTTLE FOR PROTECTED SPACE. THIS MAY BE AN ISSUE WITH OTHER VESSELS OF THE SAME BUILD WITHIN THE FURY FLEET
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2020
Resolved 24 February 2022
Resolution: The Fireboy in each engine room has a 375 cubic foot capacity. Each engine room and cofferdam combination has a total volume of approximately 300 cubic feet.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 6 January 2020
Resolved
Make shaft tubes in way of drip-less shaft seal available for inspection at Drydock. Replace/repair STBD side drip-less shaft seal boot and hose clamp.
*Prior to credit Drydock*
Action required: 705 - Other - as specified
Resolved 15 January 2020
Resolution: Completed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 January 2020
Resolved
Mount submersible bilge pump to hull in Port Head compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 February 2020
Resolution: remounted pumps
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 6 January 2020
Resolved
All deck rails on an excursion vessel accessible to passengers shall be 39.5 high and have courses at 4 inch intervals. Forward deck rails have excessive gaps that pose a potential hazard to passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 February 2020
Resolution: installed proper deck rails
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 6 January 2020
Resolved
Repair/replace gasket on watertight hatch for Port Lazerette compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 February 2020
Resolution: replaced gasket
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 January 2020
Resolved
Replace 03 Child and 11 Adult PFDs, PFDs were found not serviceable due to their inability to return to manufactures dimensions. Vessel is restricted to the carriage of 110 passengers, vessel must have 10% of child PFDs for the total amount of passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 February 2020
Resolution: replaced 03 child life jackets and 11 adult life jackets
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 6 January 2020
Resolved
Provide mousing for rigging shackles.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 February 2020
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 January 2020
Resolved
Make jib stay swageless fitting available for inspection by raising furling unit for attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 February 2020
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 6 January 2020
Resolved
Provide guard in way of upper deck staircase on Port and STBD side for the passengers to prevent possible falls to lower cabin.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 February 2020
Resolution: provided guard
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 25 February 2019
Resolved
Fireboy system protecting starboard engine space has not been serviced since 2017. Must be serviced annually.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 26 February 2019
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 25 February 2019
Resolved
Each survival craft must be in good working order and ready for immediate use. Repair/replace life floats in accordance with 46 CFR 160.027. ROUTE REDUCED TO 03 MILES.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 February 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 February 2019
Resolved
All life jackets must have TYPE I retro reflective (SOLAS Tape) in accordance with IMO resolution A.658(16)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 February 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 25 February 2019
Resolved
Child and adult life jackets must be marked and separated from adult life jackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 February 2019
Resolution: put child life jackets in marked bags
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 25 February 2019
Resolved
Each space covered by a separate fireboy system must be separated as to prevent ventilation crossover. Ensure each space is vapor tight including all access panels. Submit plans to local OCMI.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 April 2019
Resolution: Temporary means installed until credit drydock.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 25 February 2019
Resolved
COI must be posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 February 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 February 2019
Resolved
Over-current protection must be provided for each ungrounded conductor. There was not a fuse for the magnetic compass light or the anchor light. Limited to daytime operations only.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 February 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 February 2019
Resolved
Bilge pipe piercing the collision bulkhead must be fitted with a screw down valve NOT a ball valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 April 2019
Resolution: Valve replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 February 2019
Resolved
Permanently mount all submersible bilge pumps and high water alarms devices.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 April 2019
Resolution: All bilge pumps mounted
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 25 February 2019
Resolved
Provide plans and contract for installation of quick acting water tight doors between engine compartments and electrical space in accordance with vessels stability letter from 2011.
Action required: 10 - Deficiency Rectified
Due 31 January 2020
Resolved 11 April 2019
Resolution: Plans received, installation will take place at next credit drydock.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 25 February 2019
Resolved
Aft port side deck drain hose missing clamp.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 February 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 February 2019
Resolved
Main breaker on starboard side needs to be secured, it is currently loose.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 April 2019
Resolution: Breaker secured
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 February 2019
Resolved
Inverter needs grounding wire to ground
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 March 2019
Resolution: Grounding wire attached to ground.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 February 2019
Resolved
Electrical wires in port side lazaret need to be secured/supported.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 March 2019
Resolution: Wires supported.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 February 2019
Resolved
Positive terminal on port side battery is corroded.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 March 2019
Resolution: Terminal cleaned.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 February 2019
Resolved
Light fixture missing cover in port side electrical room.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 March 2019
Resolution: Lighting fixture replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 February 2019
Resolved
Handle missing from overboard discharge.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 February 2019
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 25 February 2019
Resolved
Add vessel information to emergency broadcast placard at operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 April 2019
Resolution: Information added.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 25 February 2019
Resolved
EPIRB missing registration sticker.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 April 2019
Resolution: EPIRB sticker added.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 24 April 2018
Resolved
Install additional alarm and override switch for Fireboy systems so that each system is seperate.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 May 2018
Resolution: Installed new controller, alarm and override switch for starboard hull's Fireboy system.
Operations/Management › Vessel Activity › Underway
Issued 2 February 2018
Resolved
Conduct sea trials with vessel under full sail with attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 February 2018
Resolution: Sea trial conducted.
Construction/Loadline › Hull › Bottom Plating
Issued 17 January 2018
Resolved
Crop & renew identified areas in hull with pitting. (forward port compartment).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2018
Resolution: New aluminum plate 30.5in W by 15.5in H welded in place of pitted hull. Air lance used to check welds, all sat.
Engineering › Steering Gear System › Ram
Issued 17 January 2018
Resolved
Repair/renew STBD hydraulic steering system. Demonstrate leak free operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 February 2018
Resolution: repaired
Sail Rigging › Stays/Shrouds › Wires
Issued 17 January 2018
Resolved
Replace all standing and running rigging. Rigging over 18 years old.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 February 2018
Resolution: rigging replaced.
Construction/Loadline › Structures › Superstructure
Issued 17 January 2018
Resolved
Repair/renew crack near engine room hatch just above seating on deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2018
Resolution: Special note added to monitor due to proximity of fuel tanks. Crack is no in structural member.
Construction/Loadline › Hull › Weld
Issued 17 January 2018
Resolved
Repair/renew pitting in port hull near shaft, STBD hull near bow, forward STBD compartment near keel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 January 2018
Resolution: Welds on hull ground down and new beads applied. Internal areas will be monitored, added special note.
Engineering › Steering Gear System › Rudder Stock
Issued 20 June 2017
Resolved
Vessel must repair/replace both damaged rudders
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 June 2017
Resolved 1 July 2017
Resolution: Rudders Replaced
Fire Fighting › Fire Pumps › Pressure
Issued 8 February 2017
Resolved
Prove proper operation of fire pump. Pump shall maintain 60psi at pump discharge.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 28 February 2017
Resolution: Vessel replaced fire pump. Pump maintained 60 psi.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 February 2017
Resolved
Crop and renew wasted port and starboard forward engine room bulkheads.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 15 February 2017
Resolution: Cropped and renewed wasted areas.
Documentation › Markings/Placards › Warning Signs
Issued 8 February 2017
Resolved
Label fuel cut-offs and the location of the manual fire boy activation
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 15 February 2017
Resolution: Vessel labeled fuel cut-off valves and location of manual activation of fire boy
Lifesaving › Rescue Boat Equipment › First Aid Kit
Issued 8 February 2017
Resolved
Provide a complete first aid kit
Condition: Improper/Lack of Maintenance
Due 15 February 2017
Resolved 15 February 2017
Resolution: Vessel purchased an approved first aid kit
Lifesaving › Lifefloat › Serviceable
Issued 8 February 2017
Resolved
Make repairs to life floats in accordance with manufacture's instructions
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 15 February 2017
Resolution: Repaired life float in accordance with manufacture's instructions
Communications › Radio Communications › VHF Radiotelephone
Issued 8 February 2017
Resolved
Provide VHF radio with GPS input
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 11 April 2017
Resolution: GPS input provided to VHF radio.
Documentation › Markings/Placards › Lifejacket Placard
Issued 8 February 2017
Resolved
Post donning placard for all types of PFDs onboard
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 15 February 2017
Resolution: Vessel posted placard for all types of PFDs carried onboard
Stability › Watertight Integrity › General
Issued 8 February 2017
Resolved
Replace gasket on port engine room watertight door.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 15 February 2017
Resolution: Replaced gasket on door
Fire Fighting › Fire Hoses › Number
Issued 8 February 2017
Resolved
Provide spanner wrench for fire hose
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 28 February 2017
Resolution: Provided spanner for fire hose
Lifesaving › Lifefloat › Painter
Issued 9 February 2016
Resolved
Vessel did not connect lifefloats to sea painter after leaving drydock. Properly connect all lifefloats to sea painter.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2016
Resolution: Vessel properly connected lifefloats to sea painter.
Fire Fighting › Fire Pumps › Pressure
Issued 9 February 2016
Resolved
Vessel only able to attain 50 PSI at fire pump discharge. Provide 60 PSI at fire pump discharge while nozzle is open.
Due 23 February 2016
Resolved 18 February 2016
Resolution: Vessel replaced impeller and is able to attain 60 PSI at fire pump discharge under normal engine RPM.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 9 February 2016
Resolved
Lable STBD fuel tank emergency shutoff valve pull.
Due 23 February 2016
Resolved 12 February 2016
Resolution: Vessel lable STBD fuel shutoff valve pull.
Engineering › Bilge Water Management System › Piping
Issued 9 February 2016
Resolved
Replace all wasted portions of bilge suction lines.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2016
Resolution: Vessel replaced all bilge suction lines forward of the port and starboard engine rooms.
Engineering › Bilge Water Management System › Not Operational
Issued 9 February 2016
Resolved
Prove proper operation of all bilge suction lines.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2016
Resolution: After replacing the bilge suction lines forward of the port and starboard engine room, vessel filled each bilge compartment and proved proper operation of the entire bilge system.
Engineering › Bilge Water Management System › Interface Detector
Issued 9 February 2016
Resolved
Provide visual indicator for automatic bilge pumps at the operating station or make them manual operation only.
Due 23 February 2016
Resolved 4 May 2016
Resolution: Vessel wired submersible bilge pumps for manual operation only.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 9 February 2016
Resolved
Each child size lifejacket must be stowed in a location that is appropriately marked and separated from adult lifejackets so sizes are not mistaken.
Due 23 February 2016
Resolved 4 May 2016
Resolution: Vessel moved their child size lifejackets to a seperate location and marked the location per the regulations.
Construction/Loadline › Hull › Hull Plating
Issued 7 January 2016
Resolved
Found hole from stbd snorkel locker to stbd bow void. Hole must be welded closed.
Condition: Improper/Lack of Maintenance
Due 8 February 2016
Resolved 12 January 2016
Resolution: Hole welded shut.
Electrical › Electrical Distribution System (service) › Cable
Issued 7 January 2016
Resolved
Cable/wiring in port and stbd engine spaces were not adequately supported with metal bands every 24"
Action required: 705 - Other - as specified
Due 8 February 2016
Resolved 12 January 2016
Resolution: Metal supports were added no less than 24"