11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 April 2026
No resolution recorded
Provide PFD for each person. 4 adult PFDs were missing. Vessel limited to 128 total persons.
Condition: Invalid
Action required: 705 - Other - as specified
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 15 April 2026
Resolved
Provide compass. Compass was not mounted.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2026
Resolved 6 May 2026
Resolution: Compass was mounted.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 April 2026
Resolved
Inspect nav lights. Fwd combined nav light was unsatisfactory.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2026
Resolved 6 May 2026
Resolution: Nav light sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 15 April 2026
Resolved
Provide satisfactory handrails. Port fwd railing was missing lower course.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2026
Resolved 6 May 2026
Resolution: Port fwd railing course sat.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 15 April 2026
Resolved
Provide guards for rotating machinery. Port and stbd engine front accessory guards were not mounted.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2026
Resolved 6 May 2026
Resolution: Port and stbd engine accessory covers were mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 15 April 2026
Resolved
Provide insulation for piping over 150 degrees. Port engine exhaust lagging from turbo outlet elbow to cooling water injection lagging was unsatisfactory.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 May 2026
Resolution: Port engine lagging renewed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 April 2026
Resolved
Provide garbage placard. Garbage placard was not mounted.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2026
Resolved 6 May 2026
Resolution: Garbage placard mounted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 November 2024
Resolved
An adult life jacket must be carried for each person carried on board a vessel.
Vessel is missing 02 life jackets. Vessel is limited to 130 persons on board.
46CFR180.71(a)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 6 December 2024
Resolution: 02 adult PFDs provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 November 2024
Resolved
A vessel must be provided with bilge pumps in accordance with table 182.520(a).
Starboard fore peak bilge pump is inoperable. Vessel is limited to 49 passengers.
46CFR182.520(a)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 15 November 2024
Resolution: 10c - Rectified on the spot.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 15 November 2024
Resolved
Inspection of all accessible parts of the watertight bulkheads.
Port engine space bulkhead penetration not watertight.
46CFR176.802(a)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 December 2024
Resolution: Penetration sealed.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 20 September 2024
Resolved
Satisfactory rigging Preventative Maintenance Plan was not provided. O/O provided 3rd party rigging survey report dated Sept 13, 2024. O/O to provide prevention maintenance plan per NVIC 02-16 by 20NOV2024.
Action required: 705 - Other - as specified
Due 20 November 2024
Resolved 6 December 2024
Resolution: Satisfactory plan provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 September 2024
Resolved
Complete additional inspections as required by [name withheld] rigging Preventative Maintenance Plan was not provided. O/O provided 3rd party rigging survey report dated Sept 13, 2024. 20SEP2024 additional CG-835 issued requiring O/O to provide prevention maintenance plan per NVIC 02-16 by 20NOV2024
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 September 2024
Resolution: Reviewed & accepted 3rd party rigging survey dated SEP 13, 2024. Several recommendations were made, but no discrepancies that would hinder vessels sailing. 20SEP24, Viewed crew operate vessel under full sail with ICW's. Requirment cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 August 2024
Resolved
Nothing in this subpart limits the Marine Inspector from
conducting inspections as deemed necessary.
Vessel is new to the Sector Jacksonville COTP zone. The
current routes and conditions do not allow for
operations in the Sector Jacksonville AOR and a "New To
Zone" COI inspection shall be conducted to the
satisfaction of the attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2024
Resolution: New to zone inspection completed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 30 August 2024
Resolved
Test fire pump. Stbd fire/bilge pump was inoperative. Vessel limited to 49 passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 September 2024
Resolution: Attended, informed impeller bad and new impeller installed> Observed FF Water discharged from one 1 1/2/ inch fire hose.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 30 August 2024
Resolved
Inspect watertight closures. Port and stbd WTD gaskets were unsatisfactory.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2024
Resolution: Gaskets renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 30 August 2024
Resolved
Provide required amount of flares. 8 flares were not provided.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2024
Resolution: Flares provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 August 2024
Resolved
Provide alcohol test strips. Alcohol test strips were not provided.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2024
Resolution: Test strips provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 30 August 2024
Resolved
[name withheld]. WTDs were not marked.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2024
Resolution: WTDs marked.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 30 August 2024
Resolved
Inspect lifesaving equipment. Ring buoy retroreflective material was unsatisfactory.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2024
Resolution: Retroreflective satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 30 August 2024
Resolved
Maintain subdivision watertight bulkheads. Port and STBD WTDs did not seal.
Vessel limited to 49 passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 September 2024
Resolution: Viewed and confirmed both P & S WTD's gaskets renewed, and caulk tested sat.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 18 March 2024
Resolved
Vessel operates in warm waters and is required to have survival craft for 50% of the 132 total allowed persons on board (61). 01 equipped life float is no longer in serviceable condition. Vessel is restricted to operating within three miles of shore when carrying more than 100 total people.
Action required: 705 - Other - as specified
Resolved 4 April 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 March 2024
Resolved
Replace SOLAS reflective tape on ring life buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 April 2024
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 18 March 2024
Resolved
Clearly mark the name vessel's name and hailing port on the stern in letters no less than four inches in height.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 April 2024
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 March 2023
Resolved
Life line straps on 02 of 03 life floats were degraded and missing. Replace life floats or repair to manufacturers recommendation prior to operating beyond 3 miles from shore.
Action required: 705 - Other - as specified
Resolved 22 March 2023
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 15 March 2023
Resolved
Mark the vessel's name and hailing port on a clearly visible exterior part of the stern. Letters must be clearly legible and at least 4" high.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 May 2023
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 15 March 2023
Resolved
Mark the stairways leading to the main deck with the number of passengers permitted in accordance with the vessel's Stability Letter "56 Maximum Passengers on Main Deck". Marking must be durable with numbers and letters at least 1" high.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 May 2023
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 15 March 2023
Resolved
Mark each location where life jackets are stowed in a seating bench with the number and type of life jacket stowed inside. Numbers and letters must be at least 2" high.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 May 2023
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 15 March 2023
Resolved
Provide a DSC-VHF radio with GPS location information.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 May 2023
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 8 December 2021
Resolved
Vessels operating on the high seas (beyond three miles from shore) must have on board a Category 1, 406 MHz EPIRB. Vessel's current EPIRB has a battery that expired in November 2021. Provide and EPIRB with an in date battery prior to operating more than three miles from shore.
Action required: 705 - Other - as specified
Resolved 15 December 2021
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 8 December 2021
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Install guards in front of or covering the rotating machinery on the port and starboard engines.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2022
Resolved 6 April 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 December 2021
Resolved
In the starboard engine room, replace the current fuel hose between the fuel shut off valve and the water separator as well as the hose between the water separator and the engine with fuel hoses that meet SAE J-1942 standards and fittings that meet SAE J-1475 standards.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 December 2021
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 8 December 2021
Resolved
The float-free link is not secured to the vessel at one end. Secure the link to the vessel and stow the painter in a manner that allows the life floats to float free. Prior to operating beyond 3 miles of shore.
Action required: 705 - Other - as specified
Resolved 15 December 2021
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 10 February 2020
Resolved
Grind down all identified locations and repair in accordance with NVIC 07-68 prior to credit dry dock
Action required: 705 - Other - as specified
Resolved 26 August 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 February 2020
Resolved
After reinstalling masts conduct a sea trial in the presence of a Coast Guard Marine Inspector prior to carrying passengers.
Action required: 705 - Other - as specified
Resolved 26 August 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 November 2019
Resolved
Post all pages of the COI and Stability Letter.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 December 2019
Resolution: posted
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 November 2019
Resolved
Connections to the battery must be permanent. Wing nuts are not authorized.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 December 2019
Resolution: Permanent nuts installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 November 2019
Resolved
All fuses must be of the cartridge type. Blade fuses on on panel outside engine compartment.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 November 2019
Resolution: replaced with proper fuses
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 November 2019
Resolved
Light out side engine room is missing cover.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 November 2019
Resolution: replaced cover
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 November 2019
Resolved
Fire Extinguisher at operating station handle is corroded. Replace with new 10 B:C extinguisher.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 December 2019
Resolution: replaced
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 November 2019
Resolved
Safety lines missing from aft end of forward deck in front of the concession stand. Install safety lines.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 November 2019
Resolution: reinstalled safety line
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 November 2019
Resolved
Provide current State registration for vessel and have on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 December 2019
Resolution: provided
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 19 November 2019
Resolved
Install guards on engines to prevent injury. Belts are exposed on engine and bilge manifold controls are in the space.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 November 2019
Resolution: vessel procedure is to turn engine off prior to engaging the bilge pump and not to enter the space while the engine is running.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 19 November 2019
Resolved
Replace gasket on engine room hatch to ensure vapor and watertight seal.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 November 2019
Resolution: replaced gasket on hatch
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 19 November 2019
Resolved
Adhere CURRENT NOAA registration sticker to EPIRB.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 December 2019
Resolution: New sticker added to EPIRB
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 December 2018
Resolved
Pre-engineered fixed gas fire extinguishing system must be capable of automatic actuation. During test of Fireboy system in Port engine, the system failed to shutdown engine upon simulated activation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 December 2018
Resolution: Verified proper operation of Fireboy system.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 3 December 2018
Resolved
Provide adequate means to close Port and STBD engine room vents. Spaces are protected by a fixed fire extinguishing system. Closure device must be mounted/stored in the immediate vicinity of the vent.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 April 2019
Resolution: Devices on board.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 December 2018
Resolved
Repair/replace pressure gauge on fire pump and operationally test pump to demonstrate working pressure of 60 psi on gauge.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 December 2018
Resolution: New gauge installed, 36psi achieved on gauge during test.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 3 December 2018
Resolved
Replace magnetic compass, magnetic compass not functioning properly.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 December 2018
Resolution: New compass installed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 December 2018
Resolved
Repair/replace stern navigation light, housing is broken.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 April 2019
Resolution: New light installed.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 3 December 2018
Resolved
Replace emergency broadcast placard for VHF radio.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 December 2018
Resolution: New placard installed near VHF.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 3 December 2018
Resolved
Repair/replace visual indicator light for STBD steering compartment. Audible indicator is still operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 December 2018
Resolution: New visual indicator installed and is operational.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 December 2018
Resolved
Repair/replace main sail, 03 areas on sail luff in way of attachment points on mast guide were discovered with 6-8 inch tears. If repair is conducted, provide invoice/survey from servicing facility attesting to repair and estimated lifespan of repair.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 March 2019
Resolution: Invoice received.
Sail Rigging › Spars › Spreaders and Bases
Issued 5 January 2018
Resolved
Make upper spreader available for inspection.
Action required: 705 - Other - as specified
Resolved 8 January 2018
Resolution: Made spreader available for inspection.
Engineering › Sea-water System (primary cooling) › Valve
Issued 5 January 2018
Resolved
Make all sea valves available for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 January 2018
Resolution: All sea valves were made available for inspection.
Sail Rigging › Chainplates › Materials
Issued 5 January 2018
Resolved
Make chain plates available for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 January 2018
Resolution: Chain plates were made available for inspection.
Stability › Watertight Integrity › General
Issued 14 December 2017
Resolved
Renew gaskets on watertight doors.
Action required: 705 - Other - as specified
Due 21 December 2017
Resolved 15 December 2017
Resolution: Renewed both gaskets and conducted satisfactory chalk test.
Electrical › Electric Supply System (service) › Battery Charger
Issued 14 December 2017
Resolved
Remove inverter from vessel.
Action required: 705 - Other - as specified
Due 21 December 2017
Resolved 15 December 2017
Resolution: Removed inverter from vessel.
Communications › Alarms/Indicators › High Water Alarm
Issued 14 December 2017
Resolved
Make bilge high level indicators visible at the operating station.
Action required: 705 - Other - as specified
Due 21 December 2017
Resolved 15 December 2017
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 14 December 2017
Resolved
Provide complete first aid kit.
Action required: 705 - Other - as specified
Due 21 December 2017
Resolved 15 December 2017
Resolution: Purchased new first aid kit.
Lifesaving › Lifefloat › Float-free Link
Issued 3 May 2017
Resolved
Properly attach life floats to painter and float free link.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2017
Resolution: Painter properly attached.
Sail Rigging › Running Rigging › Splices
Issued 3 May 2017
Resolved
Provide sail rigging program to include frequency of inspections and document them.
Action required: 705 - Other - as specified
Due 3 June 2017
Resolved 14 December 2017
Resolution: Rigging plan provided.
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 3 May 2017
Resolved
Submit plans for inverter to include manual for inverter, circuit protection, wire size, length of wire run, wire type to local OCMI.
Action required: 705 - Other - as specified
Due 3 June 2017
Resolved 14 December 2017
Resolution: Transferred deficiency to activity 6330015
Engineering › Sea-water System (primary cooling) › Piping
Issued 3 May 2017
Resolved
Repair leak in STBD wet exhaust system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2017
Resolution: Wet exhaust repaired prior to completion of inspection.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 3 May 2017
Resolved
Replace port engine room fixed gas fire system tank. Manufacture date 11JUN2004.
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 24 October 2017
Resolution: New cylinder installed.
Engineering › Bilge Water Management System › Pump
Issued 3 May 2017
Resolved
Port MSD space has bilge pump that is not UL listed.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 26 October 2017
Resolution: UL pump installed.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 10 March 2016
Resolved
Submit written repair proposal for damage to Port and Starboard rudders and propellers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2016
Resolution: Received repair proposal. Vessel is replacing both propellers and having the builder manufacture two new rudders for replacement.
Construction/Loadline › Hull › Keel
Issued 10 March 2016
Resolved
Submit underwater video of port and starboard hulls and rudder housings.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2016
Resolution: Vessel had professional divers video entire hull, rudder housings, and shaft housings. No damage to hull or welds was seen.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 10 March 2016
Resolved
Vessel issued no-sail 835 until satisfactory check ride has been conducted to verify satisfactory operation of new propellers and rudders as well as the absence of shaft vibration.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2016
Resolution: Conducted satisfactory sea trial.
Communications › Radio Communications › EPIRB
Issued 11 February 2016
Resolved
Register EPIRB with correct Unit Identification Number prior to operating outside 3 nm.
Action required: 705 - Other - as specified
Due 11 March 2016
Resolved 4 May 2016
Resolution: Vessel registered EPIRB.
Lifesaving › Lifefloat › Float-free Link
Issued 11 February 2016
Resolved
Attach float-free link to vessel.
Action required: 705 - Other - as specified
Due 18 February 2016
Resolved 4 May 2016
Resolution: Vessel attached lifefloats to vessel with float-free link.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 11 February 2016
Resolved
Properly label life jacket storage location including total number stored in each location.
Action required: 705 - Other - as specified
Due 18 February 2016
Resolved 4 May 2016
Resolution: Vessel labeled life jacket storage locations.
Engineering › Bilge Water Management System › Interface Detector
Issued 11 February 2016
Resolved
Provide visual indicator at operating station to identify when submersible bilge pumps are automatically operating or make them manual operation only.
Action required: 705 - Other - as specified
Due 11 March 2016
Resolved 4 May 2016
Resolution: Vessel made submersible bilge pumps manually operted only.
Engineering › Bilge Water Management System › Valve
Issued 11 February 2016
Resolved
Replace submersible bilge pump overboard valve handle in STBD holding tank space.
Action required: 705 - Other - as specified
Due 18 February 2016
Resolved 4 May 2016
Resolution: Vessel replaced handle.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 11 February 2016
Resolved
Update emergency instructions to meet regulations and post at operating station.
Action required: 705 - Other - as specified
Due 18 February 2016
Resolved 4 May 2016
Resolution: Vessel updated and posted emergency instructions.
Stability › Watertight Integrity › General
Issued 26 January 2016
Resolved
Replace starboard engine room door gasket prior to credit drydock and internal structural exam.
Action required: 705 - Other - as specified
Due 1 February 2016
Resolved 1 February 2016
Resolution: Vessel replaced starboard engine room door gasket.
Engineering › Bilge Water Management System › Valve
Issued 26 January 2016
Resolved
Install handle on the submersible bilge pump through hull valve in the space forward of the starboard side toilet.
Action required: 705 - Other - as specified
Due 1 February 2016
Resolved 1 February 2016
Resolution: Vessel installed handle on starboard side submersible bilge pump through hull valve.