Records from 2010 to 2025. Most recent: inspection, 10 February 2025.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 13.0 ft
Registered tonnagegross 1,754 / net 1,754
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2010
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 17 February 2026 · expires 31 March 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1754 - Simplified, Gross Ton
1754 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 18
10 February 2025
Administrative Inspection · COI Inspection · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8077216
21 April 2023
MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7667549
21 February 2020
Cargo Tank Internal · COI Inspection · Examination of Repairs · Internal Structural Exam · MTSA Verification · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6912988
8 February 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6618728
20 April 2018
Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6395845
1 November 2017
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6302717
14 June 2017
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6175915
3 March 2017
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6098233
17 February 2016
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5817573
17 September 2015
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5721995
18 March 2015
Examination of Repairs · COI Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5086356
31 January 2014
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4791801
21 January 2014
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4787210
1 November 2013
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4746707
21 August 2013
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4692461
6 February 2012
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4237039
21 January 2011
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3931577
31 December 2010
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3919599
Electrical › Electric Supply System (service) › Cable
Issued 3 March 2017
Resolved
Revise electrical one line drawing to address the installation of a ground conductor between the barges, that tan electrical interlock is provided between the 100 amp overboard power circuit breaker and that suitable ground detection is intalled on the distribution system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 August 2017
Resolved 1 November 2017
Resolution: One line drawing revised addressing the installation of a ground conductor between the barges, an interlock was provided between teh 100 amp overboard power circuit breaker and a suitable ground detection is installed on the distribution system.
Engineering › Fuel Oil Service System › Hose
Issued 17 February 2016
Resolved
Repair or replace fuel hose.
Condition: Invalid
Due 17 February 2016
Resolved 17 February 2016
Resolution: Replaced Hose
Electrical › Electric Generation Source (service) › Generator
Issued 21 January 2014
Resolved
Provide Ammeter for generator powering thermal fluid heater. 46 CFR 111.12-5, 46 CFR 111.30-25
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 February 2014
Resolved 31 January 2014
Resolution: Ammeter installed as per regulations.