Records from 2015 to 2025. Most recent: inspection, 10 September 2025.
Inspection history · 17
10 September 2025
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8230979
1 September 2025
PSC B · Administrative Inspection · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8217699
21 August 2025
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8214879
17 May 2023
Administrative Inspection · COC-CHEM & TVE Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7690436
17 March 2022
PSC B · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7407541
1 December 2020
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7100032
22 June 2019
Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6721667
14 May 2018
ISPS II Exam · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6408926
23 May 2017
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6153064
11 May 2017
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6147444
21 April 2017
COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6124565
19 November 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6044236
14 November 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6041015
17 January 2016
Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Annual
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5795110
30 September 2015
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5732570
29 September 2015
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5731974
29 September 2015
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5731987
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 1 September 2025
Resolved
PSCO RECEIVED REPORT FROM VESSEL THAT THE 6P CARGO TANK IS LEAKING INTO THE 5P BALLAST TANK
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 September 2025
Resolution: Vessel submitted class report attesting to permanent repair. Report can be found under documents.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 1 September 2025
Resolved
PSCO OBSERVED THAT COMPANY DID NOT REPORT CARGO TANK RADAR ISSUE TO RO OR ADMINISTRATION
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2025
Resolved 10 September 2025
Resolution: Vessel reported to class all issued deficiencies, requiring class attendance.
Electrical › Electric Generation Source (service) › Generator
Issued 21 April 2017
Resolved
0999-OTHER- The following functional requirements shall be met: fire protection systems and fire-fighting systems and appliances shall be maintained ready for use, PSCO observed that the #1 generator oil leakage alarm way bypassed by wire. 74 SOLAS II-2/141.1 lOc
generator oil leakage alarm was bypassed by wire.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 21 April 2017
Resolution: Corrected on the spot.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 21 April 2017
Resolved
0999-Other-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO
observed that the #-1 and #4 main engine cylinders had jacket water leaks. 74 SOALS 1/11 40a
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 April 2017
Resolution: PSC NOLA received a class report from NKK satisfying the requirement.