Records from 2010 to 2022. Most recent: inspection, 20 May 2022.
Inspection history · 21
20 May 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7455428
29 April 2022
PSC B · COC-TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7440396
22 April 2022
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7436149
9 February 2021
COC-CHEM & TVE Renew
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7137761
26 January 2018
Administrative Inspection · COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6343089
14 December 2017
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6324624
27 November 2017
COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6311837
25 October 2016
ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6029046
30 October 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5015187
27 October 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5012907
23 October 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5012929
21 October 2014
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5009502
24 August 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4991895
24 August 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5000343
23 August 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5000321
20 August 2014
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4960609
6 February 2012
Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4238966
10 December 2011
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 4202782
27 February 2011
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3952408
27 February 2011
COE-Offshore
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3952708
4 January 2010
COC-TVE Annual · ISPS I Exam · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3658159
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 27 November 2017
Resolved
All vessels shall have draft markings painted in a contrasting color to the hull. The vessels midship and forward draft markings are not contrasting to the hull.
46CFR32.05-1(f)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 December 2017
Resolved 14 December 2017
Resolution: Vessel submitted photos of freshly painted draft markings and load line.
Navigation › Collision/Grounding Avoidance › Radar
Issued 27 October 2014
Resolved
S Band Radar inoperable. Must be fixed prior to departure from Anchorage, AK
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2014
Resolution: Received technician report attesting to repair and operation of S-band radar.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 20 August 2014
Resolved
During testing of the overfill alarm, it was found that the alarm has a sensor that is not functioning properly. All alarms must be working properly. ensure sensor is fixed to the satisfaction of class. 46CFR 39.20-7 code 40a
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 September 2014
Resolution: Attending Coast Guard inspector verified operation of alarms.