Records from 2006 to 2020. Most recent: inspection, 7 November 2020.
Inspection history · 50
7 November 2020
Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7091315
29 October 2020
In-Service Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7086838
4 July 2020
COC-CHEM Renew · PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6995254
28 February 2020
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6917632
29 January 2020
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6898524
28 January 2020
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6897732
27 November 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6864055
11 October 2019
In-Service Inspection · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6832725
8 July 2019
ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6737184
4 December 2018
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6592035
13 September 2018
Ballast Water Examination · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6542279
1 September 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6529009
28 August 2018
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6527371
28 August 2018
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6560307
3 July 2018
COC-CHEM Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6459617
15 May 2018
ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6414752
14 January 2018
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6340062
9 July 2017
Ballast Water Examination · COC-CHEM Annual · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6198698
8 February 2017
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6084805
22 November 2016
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6046283
5 July 2016
COC-CHEM & TVE Renew · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5924682
17 October 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5008638
15 October 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5005841
14 October 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5005843
6 October 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4998581
4 October 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4998576
1 October 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4994817
28 August 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4991837
25 August 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4991870
25 August 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4991913
24 August 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4991895
24 August 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5000343
23 August 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4991891
23 August 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5000317
23 August 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5000321
23 August 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5000361
22 August 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5000215
20 August 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5000219
19 August 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5000224
17 August 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5000237
16 August 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5000274
15 August 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5000276
11 August 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5000170
5 May 2014
COC-TVE Renew · Deficiency Check · PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4846863
18 October 2007
COC-CHEM Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3081160
16 May 2007
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2929878
18 October 2006
ISPS II Exam · COC-CHEM Renew · MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex II Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2800897
17 October 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2799367
21 September 2006
Enhanced Seaway Inspection (Massena only) · Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2782190
21 September 2006
Joint Vessel Security Verification (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2782195
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 9 July 2020
Resolved
Ships shall be provided with independently driven fire pumps as follows: in cargo ships of 1,000 gross tonnage and upwards at least two. PSCO tested fire pump and found leak from fire pump gasket. Pump labeled as “fire pump G/S”
74 SOLAS(14) II-2/10.2.2.2.2
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 9 July 2020
Resolved 11 July 2020
Resolution: Received all sat tech report for service/overhaul of g/s pump.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 9 July 2020
Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed hydraulic oil leaking from the top of valve actuator NR1 STBD cargo tank, cargo fill line.
74 SOLAS(04) II-1/26.1
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 9 July 2020
Resolved 9 July 2020
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 9 July 2020
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed water mist detection panel with fault alarm stating fire detection was disconnected. Water mist system is working properly. Vessel also equipped with CO2 coverage for engine room.
74 SOLAS(14) II-2/14.2.1.2
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2020
Resolved 4 August 2020
Resolution: Received satisfactory class report
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 9 July 2020
Resolved
Each operation described in paragraph 2 of this regulation shall be fully recorded without delay in the oil record book part I, so that all entries in the book appropriate to that operation are completed. Missed entry of fuel oil (ultra low sulfur) dated 26Jun2020.
MARPOL I/17.4
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 9 July 2020
Resolved 9 July 2020
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 9 July 2020
Resolved
The oil record book part I shall be kept in such a place as to be readily available for inspection at all reasonable times, and except in the case of unmanned ships under tow, shall be kept on board the ship. It shall be reserved for a period of three years after the last entry has been made. Vessel is missing oil record book part I, from July 2017 to 02 May 2019 due to management change.
MARPOL I/17.6
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2020
Resolved 4 August 2020
Resolution: Received satisfactory class report
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 9 July 2020
Resolved
The oil record book shall be kept in such a place as to be readily available for inspection at all reasonable times and, except in the case of unmanned ships under tow, shall be kept on board the ship. It shall be preserved for a period of three years after the last entry has been made. Vessel is missing oil record book part II from July 2017 to 24 April 2018.
MARPOL I/36.7
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2020
Resolved 4 August 2020
Resolution: Received satisfactory class report
01 - Certificates & Documentation › 013 - Documents › Cargo record book
Issued 9 July 2020
Resolved
The cargo record book shall be kept in such a place as to be readily available for inspection and, except in the case of unmanned ships under tow, shall be kept on board the ship. It shall be retained for a period of three years after the last entry has been made. Vessel is missing cargo record books from July 2017 to 06 February 2019.
MARPOL II/15.5
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2020
Resolved 4 August 2020
Resolution: Received satisfactory class report
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 11 October 2019
Resolved
Subject to the provisions of paragraph 4 and 5 of regulation 3 of this annex, oil tankers of 150 gross tonnage and above shall be equipped with an oil discharge monitoring and control system approved by the administration.
Vessels installed oil discharge monitoring and control system is inoperable. Marpol I/31.1 40 a,c
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 November 2019
Resolution: Vessel provided a technician report attesting to the proper operation of the ODME.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 August 2018
Resolved
The machinery, boilers and other pressure vessels, associated piping and fittings shall be of design and construction adequate for the service for which they are inteneded and shall be so installed and protected as to reduce to a minimum and danger to persons on board, due regard being paid to ... other hazards. The vessel experienced an equipment failure while transiting navigable waters of the US which adversely affected its meneuverability and posed a hazard to vessels and ifrastructure along the Houston ship channel. Submit for review a class report to [email withheld] attesting to the cause of the equipment failure, that authorized temporary or permanant repairs have been completed and that the vessel full and normal manuverability has been restored. 74 SOLAS (14) II-1/26
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 August 2018
Resolution: Received class report attesting to proper operation of ssde #3 by affecting repairs to the governor and 3 fuel injection pumps.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 28 August 2018
Resolved
The company should identify equipment and technical systems the sudden operational failure of which may result in hazardous situations. The SMS should provide for spacific measures aimed at promoting reliability of such equipment, The vessel experienced equipment failure while transiting the navigable waters of the US which adversly impacted its fitness and capability to safely maneuver the Houston ship channel. After review of the critical equipment list. PSCO discovered that the SSDE are not included. Failure of the #3 SSDE governor provide objective evidence that the company has failed to identify that failure of this equipment will result in a hazardous situation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2018
Resolved 13 September 2018
Resolution: Received email correspondence and revised critical equipment assessment from vessel management. After further investigation, vessel management amended their critical equipment assessment to include primary and auxiliary power generation systems
Documentation › Logs/Records › Garbage Recordkeeping
Issued 18 October 2007
Resolved
The Garbage Management Plan is not ship specific. The items that can and can not be burned in the incinerator are not identified in the plan and the crew is burning everything. Mixed garbage was found in all of the containers throughout the vessel and how to dispose of hazardous waste has not been listed in the plan.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 May 2014
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 18 October 2007
Resolved
Both the cargo and bunker transfer procedures are not in accordance with the Code of Federal Regulations. The bunker transfer procedures are posted but are not specific to the items that the ship bunkers. There were no cargo transfer procedures specific to the items being discharged.
Action required: 705 - Other - as specified
Due 18 October 2007
Resolved 18 October 2007
Resolution: Gave the Master, [name withheld] and Chief Engineer sample copies of the transfer procedures.
Operations/Management › Drills/Instruction › Fire
Issued 18 October 2007
Resolved
Fire Drill; the crew did not fully established all fire boundaries and they did not respond in attacking the fire the way it is listed in their training manual section 17. Lifeboat Drill; the location of the Immersion Suits is not fully filled out in section 3.1 of the training manual and it took the crewmembers over 2, minutes to put them on as per LSA Code 2.3.1.1.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 November 2007
Resolution: Received report and pictures from the Master showing that he has conducted extended training and in lifesaving and fire fighting.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 18 October 2007
Resolved
The Ballast Water Management Plan is missing forms for sediment, sampling points and crew training.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 May 2014
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 18 October 2007
Resolved
The Shipboard Marine Pollution Emergency Plan for Noxious Liquid Substances is missing Appendixes 3 and 4, MARPOL Annex II Reg. 16.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 May 2014
Operations/Management › Cargo Transfer/Lightering › Use of Vapor Control System
Issued 18 October 2007
Resolved
The Master of the vessel could not find the approval letter from the [name withheld] stating that the Vapour Control System has been inspected / tested and meets the requirements of 46 CFR part 39. He was instructed to contact his company for a copy of the letter and make permanent the vapor studs.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 May 2014
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 16 May 2007
Resolved
Digital display for Oil Content Meter on OWS is not working. Operational test conducted, alarms, and shut down working properly. Digital display to be attested to by Class Society prior to use of OWS in U.S waters. Violation of MARPOL 73/78 Cons. Ed. 2002 Annex I Reg 16.5
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 June 2007
Resolution: RCVD CLASS REPORT ATTESTING TO REPAIR OF OWN DIGITAL DISPLAY