MAURY USCG vessel records Sign in
← All vessels

MTM ANTWERP

MTM ANTWERP is a 2003 tank ship. The Coast Guard has recorded 28 inspections since 2006, most recently in May 2023, along with 8 deficiencies and 3 operational controls.

Records from 2006 to 2023. Most recent: inspection, 2 May 2023.

Built
2003
Last inspected
2 May 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9291456 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V2587
806335
Flag
SINGAPORE
—
Maury page id
psix-806335

Inspections, by type

…with no type recorded15
Years with a record 12 calendar years (2006–2023)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it11628 - Convention (Subpart B), Gross Ton
6418 - Convention (Subpart B), Net Ton
20703 - Dead Weight, Metric Ton
25978 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 3

Inspection history · 28

2 May 2023 COC-CHEM & TVE Renew · PSC A
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7676078
18 October 2021 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7329958
1 September 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7047981
16 August 2020 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7034256
27 December 2019 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6876636
4 September 2018 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6543829
15 March 2018 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6372188
19 August 2016 Enhanced Seaway Inspection (Massena only) · Administrative Inspection · Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5979157
29 July 2016 COC-CHEM Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5950080
25 August 2014 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4991870
23 August 2014 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4991907
12 August 2014 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5000175
11 August 2014 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5000170
7 August 2014 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4995305
7 August 2014 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4995336
5 August 2014 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4995317
4 August 2014 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4995313
4 August 2014 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4995315
3 August 2014 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4995309
3 December 2011 COC-CHEM Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4200783
27 December 2009 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3655568
5 March 2008 COC-CHEM Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3156050
3 July 2007 ISPS II Exam · Ballast Water Examination · COC-CHEM Annual
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2982252
12 October 2006 MARPOL Annex V Examination · NPV Safety Exam · ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2798546
23 February 2006 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2590554
20 February 2006 ISPS II Exam · COC-CHEM Renew · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2588504
19 February 2006 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2588275
13 February 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2584667

Deficiency record · 8

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 May 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessels cargo monitoring system is inoperable. USCG could not conduct COC requirements. Vessel is prohibited from conducting cargo operations until the cargo monitoring system has been tested satisfactory by flag/class. Once condition of class report has been received and approved, USCG will return to complete the remainder of COC exam. 16ac
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2023
Resolved 3 May 2023
Resolution: Technician replaced faulty modules that caused Error 1 display. System operational.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 27 December 2019 Resolved
07102 - Fire Safety - Requirements for tankers in this chapter shall apply to tankers carrying crude oil or petroleum products having a flashpoints not exceeding 60 degrees Celsius, as determined by an approved flashpoint apparatus, and a Reid vapor pressures which is below the atmospheric pressure or liquid products having similar fire hazard. PSCO could not observe the proper operation of the N2 generator due to a sea water cooling pump issue. SOLAS 74 (2014) II-2/2.6.1
Action required: 10 - Deficiency Rectified
Due 27 December 2019
Resolved 27 December 2019
Resolution: PSCO was able to verify proper operation N2 generator.
Engineering › Freshwater System (injector cooling) › Drainage
Issued 29 July 2016 Resolved
1410 - Propulsion main engine - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects wil remain fit to proceeded to sea without danger to the ship or persons onboard. Excessive jacket water leaking from main engine cylinders #2, 4, and 5. 74SOLAS(14)CH I REG 11(a) 17 a, c
Due 29 July 2016
Resolved 30 July 2016
Resolution: Received a class report attesting to the repairs of the 4 cylinder and giving a condition of class for cylinders 2 and 5 not to exceed 28SEP2016. See attached class report for further info.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 29 July 2016 Resolved
1840 - Instramental - Loading operations shall be terminated at once in the event of any system essential for safe loading becoming inoperative. High level alarm indicator in the cargo control room is falsely indicating a high level in cargo tanks 2 port, 6 port, 7 port. Vessel shall not load cargo in cargo tanks 2 port, 6 port, 7 port, in the U.S. until the deficiency is rectified. 40 a, c
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 July 2016
Resolution: Received class report giving a condition for the replacement of the high-level alarms no later than 30JUN2016. Refer to attached class report for further information.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 3 December 2011 Resolved
Vessels ODME does not indicate when the overboard valve is open as designed. Marpol 73/78 Annex I / Reg. 31.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 December 2011
Resolution: Received class report attesting to the repair to the valve.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 3 December 2011 Resolved
Vessels #9 cargo pump continously indicates that the pump is running, providing no indication when the pump is stopped, which could result in a pollution incident. Marpol 73/78 - Annex I / Reg 6.4.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 December 2011
Resolution: Received class report attesting to the proper repair of the cargo pump.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 3 July 2007 Resolved
There is no record of garbage incineration in the garbage record book between 08AUG06 to 05JUL07; MARPOL Cons 2006 Annex V Reg 9. 70A/B-Rectify deficiency to the satisfaction of class and administration prior to next U.S. port after sailing foreign.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 August 2007
Resolution: Sec Delaware Bay inspected Garbage Log Book Entries & compared to Waste Management Plan. Vessel has been recording all incineration since previous inspection.
Navigation › Collision/Grounding Avoidance › Radar
Issued 20 February 2006 Resolved
Vessel issued Letter of Deviation for inoperable 3 cm radar.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2006
Resolution: Received technician''s report stating 3 cm radar is functioning properly.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.