MAURY USCG vessel records Sign in
← All vessels

MMLP 321

MMLP 321 is a 2010 tank barge. The Coast Guard has recorded 21 inspections since 2010, most recently in June 2026, along with 3 deficiencies and 2 casualty investigations between 2012 and 2024.

Records from 2010 to 2026. Most recent: inspection, 8 June 2026.

Built
2010
Last inspected
8 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

1047845
Flag
UNITED STATES
—
Maury page id
psix-1047845

Inspections, by type

…with no type recorded3
Years with a record 14 calendar years (2010–2026)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS INC · ASHLAND CITY, TN, UNITED STATES · built 2010
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portBEAUMONT, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 September 2025 · expires 31 October 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 4

Inspection history · 21

8 June 2026 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8394972
26 February 2025 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8085316
19 February 2025 Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8081724
5 June 2024 Annual Inspection · Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7928851
18 May 2024 Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7914658
15 May 2024 Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7913210
15 May 2024 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7913257
25 April 2023 Periodic Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7675682
31 May 2022 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7466589
14 April 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7431115
10 May 2021 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7190722
21 January 2020 MTSA Verification · Drydock Exam · Internal Structural Exam · Examination of Repairs · Cargo Tank Internal · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6893486
5 March 2019 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6636504
11 April 2017 MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6121173
4 March 2016 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5825351
5 February 2015 Internal Structural Exam · Examination of Repairs · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5062609
14 January 2014 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4780718
24 April 2012 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4290182
10 March 2012 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4262623
9 March 2012 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4268906
27 January 2010 Administrative Inspection · Deadweight Survey · Initial Construction-Excluding Oversight · Initial Certification · Hull Examination · Internal Structural Exam · MTSA Verification · Cargo Tank Internal
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3657166

Deficiency record · 3

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 June 2026 Resolved
The Cargo Authority Attachment to the COI indicated PV venting is required for all cargo tanks in accordance with the minimum requirements for 46 CFR Subchapter "O" cargoes. PV venting shall not relieve at a vacuum corresponding to a vacuum in the cargo space between 0.0 psia and -0.5 psia and must be in accordance with approved documentation by the Marine Safety Center. The vessel has PV venting for the cargo space at 1.0 psia and -0.1 psia. Prior to carriage of cargo requiring PV venting, the vessel must conform to Marine Safety Center standards.
Action required: 705 - Other - as specified
Resolved 29 June 2026
Resolution: Vessel rep capped off the valves.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 18 May 2024 Resolved
Scantlings, material, and workmanship, subdivision of cargo spaces, fitting cofferdams, and testing of tanks shall be at least equivalent to the requirements of the American Bureau of Shipping or other recognized Class Society. Vessel has multiple insets and hull damage located at the stern void (top side & internal) as well as damaged containment tray, port side cargo header, and #3 port cargo tank top puncture. Vessel is authorized one time discharge of cargo to sister barge at T&T Salvage Marine Pier in Galveston, TX. Discharge of cargo shall be conducted in accordance with the approved Lightering plan. Upon completion of cargo offload, vessel is authorized one time transit to Southwest Channelview Shipyard in Houston, TX. Transit to repair facility shall be completed in accordance with the approved Transit plan. All vessel movement shall be coordinated with the Houston Vessel Traffic Service, Houston Domestics Office, and MSU Texas City Domestic Office. 46 CFR 32.60-1(a)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2024
Resolved 7 June 2024
Resolution: Shipyard cropped and renewed line as per plate summary (attached to activity).
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 10 May 2021 Resolved
Any tank vessel which is equipped with an internal combustion engine driven cargo pump on the weather deck shall be provided with minimum of one remote shutdown station. The remote quick acting manual shall be installed on the engine so as to provide a quick and effective means of stopping engine. The port side prime mover failed to shutdown due to O-ring failure. Repairs must be satisfactory to attending Marine Inspector. 46 CFR 32.50-35
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 May 2021
Resolution: Crew replaced o-ring shutdown tested sat.

Casualty record · 2

9 March 2012Routine · role: Involved in a Marine Casualty · activity 4268906
15 May 2024Major Marine Casualty · role: Acknowledged Pollution Source · at PELICAN ISLAND BRIDGE · activity 7913257
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.