Records from 2011 to 2026. Most recent: inspection, 8 June 2026.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS INC · ASHLAND CITY, TN, UNITED STATES · built 2010
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portBEAUMONT, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 September 2025 · expires 31 October 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 20
8 June 2026
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8394984
7 March 2025
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8090112
24 February 2025
Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8084590
6 June 2024
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7925912
15 May 2024
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7913257
25 April 2023
Periodic Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7675686
31 May 2022
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7466589
14 April 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7431129
6 May 2021
Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7190721
21 January 2020
Examination of Repairs · Cargo Tank Internal · COI Inspection · Drydock Exam · Internal Structural Exam · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6893468
23 October 2019
Bulk Liquid Transfer Monitor
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6840380
5 March 2019
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6636530
11 April 2017
MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6121179
4 March 2016
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5825354
5 February 2015
COI Inspection · MTSA Verification · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5062616
28 February 2014
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4816357
14 January 2014
Examination of Repairs · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4780722
24 April 2012
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4290184
10 March 2012
Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4262637
9 March 2012
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4268906
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 June 2026
Resolved
The Cargo Authority Attachment to the COI indicated PV
venting is required for all cargo tanks in accordance
with the minimum requirements for 46 CFR Subchapter "O"
cargoes. PV venting shall not relieve at a vacuum
corresponding to a vacuum in the cargo space between 0.0
psia and -0.5 psia and must be in accordance with
approved documentation by the Marine Safety Center. The
vessel has PV venting for the cargo space at 1.0 psia
and -0.1 psia. Prior to carriage of cargo requiring PV
venting, the vessel must conform to Marine Safety Center
standards.
Action required: 705 - Other - as specified
Resolved 29 June 2026
Resolution: Received photo of removed P/V valves, see documents tab.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 10 May 2021
Resolved
Any vessel which is equipped with an internal combustion engine driven cargo pump on the weather deck shall be provided with an min. of one remote manual shutdown station. Vessels STBD prime mover was not able to be shutdown due to a bad o-ring on the intake. Repair to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 May 2021
Resolution: Vessel crew replaced o-ring and shutdown tested sat.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 10 May 2021
Resolved
Each cargo tank of a tank barge must have one of the following liquid overfill protection arrangements... Actuates as alarm and automatic shutdown system. Vessels high level and overflow alarms are not operating as designed. Vessel is restricted to cargoes that do not require vapor collection until repaired and tested. Vessel meets 33 CFR 155.480 with 1M stick and spill valve.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 May 2021
Resolution: Crew replaced three sensors and all high level and overflow alarms tested sat.